1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
|
* CoreSight Components:
CoreSight components are compliant with the ARM CoreSight architecture
specification and can be connected in various topologies to suit a particular
SoCs tracing needs. These trace components can generally be classified as
sinks, links and sources. Trace data produced by one or more sources flows
through the intermediate links connecting the source to the currently selected
sink. Each CoreSight component device should use these properties to describe
its hardware characteristcs.
* Required properties for all components *except* non-configurable replicators
and non-configurable funnels:
* compatible: These have to be supplemented with "arm,primecell" as
drivers are using the AMBA bus interface. Possible values include:
- Embedded Trace Buffer (version 1.0):
"arm,coresight-etb10", "arm,primecell";
- Trace Port Interface Unit:
"arm,coresight-tpiu", "arm,primecell";
- Trace Memory Controller, used for Embedded Trace Buffer(ETB),
Embedded Trace FIFO(ETF) and Embedded Trace Router(ETR)
configuration. The configuration mode (ETB, ETF, ETR) is
discovered at boot time when the device is probed.
"arm,coresight-tmc", "arm,primecell";
- Trace Programmable Funnel:
"arm,coresight-dynamic-funnel", "arm,primecell";
"arm,coresight-funnel", "arm,primecell"; (OBSOLETE. For
backward compatibility and will be removed)
- Embedded Trace Macrocell (version 3.x) and
Program Flow Trace Macrocell:
"arm,coresight-etm3x", "arm,primecell";
- Embedded Trace Macrocell (version 4.x), with memory mapped access.
"arm,coresight-etm4x", "arm,primecell";
- Embedded Trace Macrocell (version 4.x), with system register access only.
"arm,coresight-etm4x-sysreg";
- Coresight programmable Replicator :
"arm,coresight-dynamic-replicator", "arm,primecell";
- System Trace Macrocell:
"arm,coresight-stm", "arm,primecell"; [1]
- Coresight Address Translation Unit (CATU)
"arm,coresight-catu", "arm,primecell";
- Coresight Cross Trigger Interface (CTI):
"arm,coresight-cti", "arm,primecell";
See coresight-cti.yaml for full CTI definitions.
* reg: physical base address and length of the register
set(s) of the component.
* clocks: the clocks associated to this component.
* clock-names: the name of the clocks referenced by the code.
Since we are using the AMBA framework, the name of the clock
providing the interconnect should be "apb_pclk", and some
coresight blocks also have an additional clock "atclk", which
clocks the core of that coresight component. The latter clock
is optional.
* port or ports: see "Graph bindings for Coresight" below.
* Additional required property for Embedded Trace Macrocell (version 3.x and
version 4.x):
* cpu: the cpu phandle this ETM/PTM is affined to. Do not
assume it to default to CPU0 if omitted.
* Additional required properties for System Trace Macrocells (STM):
* reg: along with the physical base address and length of the register
set as described above, another entry is required to describe the
mapping of the extended stimulus port area.
* reg-names: the only acceptable values are "stm-base" and
"stm-stimulus-base", each corresponding to the areas defined in "reg".
* Required properties for Coresight Cross Trigger Interface (CTI)
See coresight-cti.yaml for full CTI definitions.
* Required properties for devices that don't show up on the AMBA bus, such as
non-configurable replicators and non-configurable funnels:
* compatible: Currently supported value is (note the absence of the
AMBA markee):
- Coresight Non-configurable Replicator:
"arm,coresight-static-replicator";
"arm,coresight-replicator"; (OBSOLETE. For backward
compatibility and will be removed)
- Coresight Non-configurable Funnel:
"arm,coresight-static-funnel";
* port or ports: see "Graph bindings for Coresight" below.
* Optional properties for all components:
* arm,coresight-loses-context-with-cpu : boolean. Indicates that the
hardware will lose register context on CPU power down (e.g. CPUIdle).
An example of where this may be needed are systems which contain a
coresight component and CPU in the same power domain. When the CPU
powers down the coresight component also powers down and loses its
context. This property is currently only used for the ETM 4.x driver.
* Optional properties for ETM/PTMs:
* arm,cp14: must be present if the system accesses ETM/PTM management
registers via co-processor 14.
* qcom,skip-power-up: boolean. Indicates that an implementation can
skip powering up the trace unit. TRCPDCR.PU does not have to be set
on Qualcomm Technologies Inc. systems since ETMs are in the same power
domain as their CPU cores. This property is required to identify such
systems with hardware errata where the CPU watchdog counter is stopped
when TRCPDCR.PU is set.
* Optional property for TMC:
* arm,buffer-size: size of contiguous buffer space for TMC ETR
(embedded trace router). This property is obsolete. The buffer size
can be configured dynamically via buffer_size property in sysfs.
* arm,scatter-gather: boolean. Indicates that the TMC-ETR can safely
use the SG mode on this system.
* Optional property for CATU :
* interrupts : Exactly one SPI may be listed for reporting the address
error
* Optional property for configurable replicators:
* qcom,replicator-loses-context: boolean. Indicates that the replicator
will lose register context when AMBA clock is removed which is observed
in some replicator designs.
Graph bindings for Coresight
-------------------------------
Coresight components are interconnected to create a data path for the flow of
trace data generated from the "sources" to their collection points "sink".
Each coresight component must describe the "input" and "output" connections.
The connections must be described via generic DT graph bindings as described
by the "bindings/graph.txt", where each "port" along with an "endpoint"
component represents a hardware port and the connection.
* All output ports must be listed inside a child node named "out-ports"
* All input ports must be listed inside a child node named "in-ports".
* Port address must match the hardware port number.
Example:
1. Sinks
etb@20010000 {
compatible = "arm,coresight-etb10", "arm,primecell";
reg = <0 0x20010000 0 0x1000>;
clocks = <&oscclk6a>;
clock-names = "apb_pclk";
in-ports {
port {
etb_in_port: endpoint@0 {
remote-endpoint = <&replicator_out_port0>;
};
};
};
};
tpiu@20030000 {
compatible = "arm,coresight-tpiu", "arm,primecell";
reg = <0 0x20030000 0 0x1000>;
clocks = <&oscclk6a>;
clock-names = "apb_pclk";
in-ports {
port {
tpiu_in_port: endpoint@0 {
remote-endpoint = <&replicator_out_port1>;
};
};
};
};
etr@20070000 {
compatible = "arm,coresight-tmc", "arm,primecell";
reg = <0 0x20070000 0 0x1000>;
clocks = <&oscclk6a>;
clock-names = "apb_pclk";
in-ports {
port {
etr_in_port: endpoint {
remote-endpoint = <&replicator2_out_port0>;
};
};
};
out-ports {
port {
etr_out_port: endpoint {
remote-endpoint = <&catu_in_port>;
};
};
};
};
2. Links
replicator {
/* non-configurable replicators don't show up on the
* AMBA bus. As such no need to add "arm,primecell".
*/
compatible = "arm,coresight-static-replicator";
out-ports {
#address-cells = <1>;
#size-cells = <0>;
/* replicator output ports */
port@0 {
reg = <0>;
replicator_out_port0: endpoint {
remote-endpoint = <&etb_in_port>;
};
};
port@1 {
reg = <1>;
replicator_out_port1: endpoint {
remote-endpoint = <&tpiu_in_port>;
};
};
};
in-ports {
port {
replicator_in_port0: endpoint {
remote-endpoint = <&funnel_out_port0>;
};
};
};
};
funnel {
/*
* non-configurable funnel don't show up on the AMBA
* bus. As such no need to add "arm,primecell".
*/
compatible = "arm,coresight-static-funnel";
clocks = <&crg_ctrl HI3660_PCLK>;
clock-names = "apb_pclk";
out-ports {
port {
combo_funnel_out: endpoint {
remote-endpoint = <&top_funnel_in>;
};
};
};
in-ports {
#address-cells = <1>;
#size-cells = <0>;
port@0 {
reg = <0>;
combo_funnel_in0: endpoint {
remote-endpoint = <&cluster0_etf_out>;
};
};
port@1 {
reg = <1>;
combo_funnel_in1: endpoint {
remote-endpoint = <&cluster1_etf_out>;
};
};
};
};
funnel@20040000 {
compatible = "arm,coresight-dynamic-funnel", "arm,primecell";
reg = <0 0x20040000 0 0x1000>;
clocks = <&oscclk6a>;
clock-names = "apb_pclk";
out-ports {
port {
funnel_out_port0: endpoint {
remote-endpoint =
<&replicator_in_port0>;
};
};
};
in-ports {
#address-cells = <1>;
#size-cells = <0>;
port@0 {
reg = <0>;
funnel_in_port0: endpoint {
remote-endpoint = <&ptm0_out_port>;
};
};
port@1 {
reg = <1>;
funnel_in_port1: endpoint {
remote-endpoint = <&ptm1_out_port>;
};
};
port@2 {
reg = <2>;
funnel_in_port2: endpoint {
remote-endpoint = <&etm0_out_port>;
};
};
};
};
3. Sources
ptm@2201c000 {
compatible = "arm,coresight-etm3x", "arm,primecell";
reg = <0 0x2201c000 0 0x1000>;
cpu = <&cpu0>;
clocks = <&oscclk6a>;
clock-names = "apb_pclk";
out-ports {
port {
ptm0_out_port: endpoint {
remote-endpoint = <&funnel_in_port0>;
};
};
};
};
ptm@2201d000 {
compatible = "arm,coresight-etm3x", "arm,primecell";
reg = <0 0x2201d000 0 0x1000>;
cpu = <&cpu1>;
clocks = <&oscclk6a>;
clock-names = "apb_pclk";
out-ports {
port {
ptm1_out_port: endpoint {
remote-endpoint = <&funnel_in_port1>;
};
};
};
};
4. STM
stm@20100000 {
compatible = "arm,coresight-stm", "arm,primecell";
reg = <0 0x20100000 0 0x1000>,
<0 0x28000000 0 0x180000>;
reg-names = "stm-base", "stm-stimulus-base";
clocks = <&soc_smc50mhz>;
clock-names = "apb_pclk";
out-ports {
port {
stm_out_port: endpoint {
remote-endpoint = <&main_funnel_in_port2>;
};
};
};
};
5. CATU
catu@207e0000 {
compatible = "arm,coresight-catu", "arm,primecell";
reg = <0 0x207e0000 0 0x1000>;
clocks = <&oscclk6a>;
clock-names = "apb_pclk";
interrupts = <GIC_SPI 4 IRQ_TYPE_LEVEL_HIGH>;
in-ports {
port {
catu_in_port: endpoint {
remote-endpoint = <&etr_out_port>;
};
};
};
};
[1]. There is currently two version of STM: STM32 and STM500. Both
have the same HW interface and as such don't need an explicit binding name.
|