authorStanislaw Gruszka <sgruszka@redhat.com>2013-08-26 15:18:53 +0200
committerJohn W. Linville <linville@tuxdriver.com>2013-08-26 14:10:40 -0400
commit6e956da2027c767859128b9bfef085cf2a8e233b (patch)
treed7a0bc42d55e54f846cb836555cf67dea6b11ab3 /net/sunrpc
parent93ba2a856f75aead35a043f169a49ce398afe737 (diff)
downloadlinux-6e956da2027c767859128b9bfef085cf2a8e233b.tar.bz2
rt2800: fix wrong TX power compensation
We should not do temperature compensation on devices without EXTERNAL_TX_ALC bit set (called DynamicTxAgcControl on vendor driver). Such devices can have totally bogus TSSI parameters on the EEPROM, but still threaded by us as valid and result doing wrong TX power calculations. This fix inability to connect to AP on slightly longer distance on some Ralink chips/devices. Reported-and-tested-by: Fabien ADAM <id2ndr@crocobox.org> Cc: stable@vger.kernel.org Signed-off-by: Stanislaw Gruszka <sgruszka@redhat.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>
Diffstat (limited to 'net/sunrpc')
0 files changed, 0 insertions, 0 deletions