summaryrefslogtreecommitdiffstats
path: root/drivers
diff options
context:
space:
mode:
authorMark Brown <broonie@opensource.wolfsonmicro.com>2011-12-05 10:58:41 +0000
committerMark Brown <broonie@opensource.wolfsonmicro.com>2011-12-05 18:59:10 +0000
commitab62aa931ed3512bc67857a03636756b96c78eae (patch)
treedf16ee25353534bd6a1acac205dc2a27e985ee47 /drivers
parent068df0f34e81bc06c5eb5012ec2eda25624e87aa (diff)
downloadlinux-ab62aa931ed3512bc67857a03636756b96c78eae.tar.bz2
regulator: If a single voltage is set with device tree then set apply_uV
Otherwise there is no way in the bindings to configure a fixed voltage via software. It seems reasonable to assume that if the binding explicitly specifies a voltage we want to actually use that voltage. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/regulator/of_regulator.c3
1 files changed, 3 insertions, 0 deletions
diff --git a/drivers/regulator/of_regulator.c b/drivers/regulator/of_regulator.c
index acd7045d1601..b7b3fc3b09e2 100644
--- a/drivers/regulator/of_regulator.c
+++ b/drivers/regulator/of_regulator.c
@@ -34,6 +34,9 @@ static void of_get_regulation_constraints(struct device_node *np,
/* Voltage change possible? */
if (constraints->min_uV != constraints->max_uV)
constraints->valid_ops_mask |= REGULATOR_CHANGE_VOLTAGE;
+ /* Only one voltage? Then make sure it's set. */
+ if (constraints->min_uV == constraints->max_uV)
+ constraints->apply_uV = true;
uV_offset = of_get_property(np, "regulator-microvolt-offset", NULL);
if (uV_offset)