diff options
author | Alvin Lee <Alvin.Lee2@amd.com> | 2022-06-16 10:58:08 -0400 |
---|---|---|
committer | Alex Deucher <alexander.deucher@amd.com> | 2022-07-25 09:31:01 -0400 |
commit | a983d263186996002ecafc72f9a0dc5a3a2bfd6f (patch) | |
tree | 0b8d2b0b06e7c379fb4e835f7d8d98619184d488 /drivers | |
parent | 074293dd9f61f11898f1f6e01f1560fd4c474025 (diff) | |
download | linux-a983d263186996002ecafc72f9a0dc5a3a2bfd6f.tar.bz2 |
drm/amd/display: Don't set dram clock change requirement for SubVP
[Description]
In general cases we want to keep the dram clock change requirement (we
prefer configs that support MCLK switch). Only override to false for
SubVP.
Tested-by: Daniel Wheeler <daniel.wheeler@amd.com>
Acked-by: Alan Liu <HaoPing.Liu@amd.com>
Signed-off-by: Alvin Lee <Alvin.Lee2@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/gpu/drm/amd/display/dc/dcn32/dcn32_resource.c | 10 |
1 files changed, 10 insertions, 0 deletions
diff --git a/drivers/gpu/drm/amd/display/dc/dcn32/dcn32_resource.c b/drivers/gpu/drm/amd/display/dc/dcn32/dcn32_resource.c index f913daabcca5..92d87745d933 100644 --- a/drivers/gpu/drm/amd/display/dc/dcn32/dcn32_resource.c +++ b/drivers/gpu/drm/amd/display/dc/dcn32/dcn32_resource.c @@ -2984,6 +2984,7 @@ int dcn32_populate_dml_pipes_from_context( int i, pipe_cnt; struct resource_context *res_ctx = &context->res_ctx; struct pipe_ctx *pipe; + bool subvp_in_use = false; dcn20_populate_dml_pipes_from_context(dc, context, pipes, fast_validate); @@ -3006,6 +3007,7 @@ int dcn32_populate_dml_pipes_from_context( switch (pipe->stream->mall_stream_config.type) { case SUBVP_MAIN: pipes[pipe_cnt].pipe.src.use_mall_for_pstate_change = dm_use_mall_pstate_change_sub_viewport; + subvp_in_use = true; break; case SUBVP_PHANTOM: pipes[pipe_cnt].pipe.src.use_mall_for_pstate_change = dm_use_mall_pstate_change_phantom_pipe; @@ -3076,6 +3078,14 @@ int dcn32_populate_dml_pipes_from_context( dcn32_update_det_override_for_mpo(dc, context, pipes); + // In general cases we want to keep the dram clock change requirement + // (prefer configs that support MCLK switch). Only override to false + // for SubVP + if (subvp_in_use) + context->bw_ctx.dml.soc.dram_clock_change_requirement_final = false; + else + context->bw_ctx.dml.soc.dram_clock_change_requirement_final = true; + return pipe_cnt; } |