diff options
author | Huazhong Tan <tanhuazhong@huawei.com> | 2020-01-04 10:49:31 +0800 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2020-01-06 13:26:25 -0800 |
commit | 7f39febf2e08a227e9696d2ebac2637d9ed98efc (patch) | |
tree | 9168fcedacb3b0edaf58d52b51c30258bc389c7d /drivers | |
parent | 7061867b59e0e5231b64655356c67ec31f44bc01 (diff) | |
download | linux-7f39febf2e08a227e9696d2ebac2637d9ed98efc.tar.bz2 |
net: hns3: modify an unsuitable reset level for hardware error
According to hardware user manual, when hardware reports error
'roc_pkt_without_key_port', the driver should assert function
reset to do the recovery.
So this patch uses HNAE3_FUNC_RESET to replace HNAE3_GLOBAL_RESET.
Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_err.c | 4 |
1 files changed, 2 insertions, 2 deletions
diff --git a/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_err.c b/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_err.c index dc66b4e13377..f8127d72d645 100644 --- a/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_err.c +++ b/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_err.c @@ -505,7 +505,7 @@ static const struct hclge_hw_error hclge_ssu_mem_ecc_err_int[] = { static const struct hclge_hw_error hclge_ssu_port_based_err_int[] = { { .int_msk = BIT(0), .msg = "roc_pkt_without_key_port", - .reset_level = HNAE3_GLOBAL_RESET }, + .reset_level = HNAE3_FUNC_RESET }, { .int_msk = BIT(1), .msg = "tpu_pkt_without_key_port", .reset_level = HNAE3_GLOBAL_RESET }, { .int_msk = BIT(2), .msg = "igu_pkt_without_key_port", @@ -599,7 +599,7 @@ static const struct hclge_hw_error hclge_ssu_ets_tcg_int[] = { static const struct hclge_hw_error hclge_ssu_port_based_pf_int[] = { { .int_msk = BIT(0), .msg = "roc_pkt_without_key_port", - .reset_level = HNAE3_GLOBAL_RESET }, + .reset_level = HNAE3_FUNC_RESET }, { .int_msk = BIT(9), .msg = "low_water_line_err_port", .reset_level = HNAE3_NONE_RESET }, { .int_msk = BIT(10), .msg = "hi_water_line_err_port", |