summaryrefslogtreecommitdiffstats
path: root/drivers
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2015-08-20 11:32:33 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2015-08-20 11:32:33 -0700
commit3bd8f7d87dd12a97f0215f0d1a4afdd20ba49854 (patch)
tree029e0090e05f3b36b58f942f12f6e5f93a2cc7cf /drivers
parent1b647a166f07dcf08709c8606470f4b17a4aa11d (diff)
parent1afb9c539daebc2c8a7b33d0e0b8fc9f74671b02 (diff)
downloadlinux-3bd8f7d87dd12a97f0215f0d1a4afdd20ba49854.tar.bz2
Merge branch 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal
Pull thermal fixes from Eduardo Valentin: "Last minute fixes on the thermal-soc tree. There is a fix of a long lasting bug in cpu cooling device, thanks for RMK for being pushing this" * 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal: thermal/cpu_cooling: update policy limits if clipped_freq < policy->max thermal/cpu_cooling: rename max_freq as clipped_freq in notifier thermal/cpu_cooling: rename cpufreq_val as clipped_freq thermal/cpu_cooling: convert 'switch' block to 'if' block in notifier thermal/cpu_cooling: quit early after updating policy thermal/cpu_cooling: No need to initialize max_freq to 0 thermal: cpu_cooling: fix lockdep problems in cpu_cooling thermal: power_allocator: do not use devm* interfaces
Diffstat (limited to 'drivers')
-rw-r--r--drivers/thermal/cpu_cooling.c73
-rw-r--r--drivers/thermal/power_allocator.c8
2 files changed, 48 insertions, 33 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 6509c61b9648..620dcd405ff6 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -68,7 +68,7 @@ struct power_table {
* registered cooling device.
* @cpufreq_state: integer value representing the current state of cpufreq
* cooling devices.
- * @cpufreq_val: integer value representing the absolute value of the clipped
+ * @clipped_freq: integer value representing the absolute value of the clipped
* frequency.
* @max_level: maximum cooling level. One less than total number of valid
* cpufreq frequencies.
@@ -91,7 +91,7 @@ struct cpufreq_cooling_device {
int id;
struct thermal_cooling_device *cool_dev;
unsigned int cpufreq_state;
- unsigned int cpufreq_val;
+ unsigned int clipped_freq;
unsigned int max_level;
unsigned int *freq_table; /* In descending order */
struct cpumask allowed_cpus;
@@ -107,6 +107,9 @@ struct cpufreq_cooling_device {
static DEFINE_IDR(cpufreq_idr);
static DEFINE_MUTEX(cooling_cpufreq_lock);
+static unsigned int cpufreq_dev_count;
+
+static DEFINE_MUTEX(cooling_list_lock);
static LIST_HEAD(cpufreq_dev_list);
/**
@@ -185,14 +188,14 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
{
struct cpufreq_cooling_device *cpufreq_dev;
- mutex_lock(&cooling_cpufreq_lock);
+ mutex_lock(&cooling_list_lock);
list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) {
- mutex_unlock(&cooling_cpufreq_lock);
+ mutex_unlock(&cooling_list_lock);
return get_level(cpufreq_dev, freq);
}
}
- mutex_unlock(&cooling_cpufreq_lock);
+ mutex_unlock(&cooling_list_lock);
pr_err("%s: cpu:%d not part of any cooling device\n", __func__, cpu);
return THERMAL_CSTATE_INVALID;
@@ -215,29 +218,35 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
unsigned long event, void *data)
{
struct cpufreq_policy *policy = data;
- unsigned long max_freq = 0;
+ unsigned long clipped_freq;
struct cpufreq_cooling_device *cpufreq_dev;
- switch (event) {
+ if (event != CPUFREQ_ADJUST)
+ return NOTIFY_DONE;
- case CPUFREQ_ADJUST:
- mutex_lock(&cooling_cpufreq_lock);
- list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
- if (!cpumask_test_cpu(policy->cpu,
- &cpufreq_dev->allowed_cpus))
- continue;
+ mutex_lock(&cooling_list_lock);
+ list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
+ if (!cpumask_test_cpu(policy->cpu, &cpufreq_dev->allowed_cpus))
+ continue;
- max_freq = cpufreq_dev->cpufreq_val;
+ /*
+ * policy->max is the maximum allowed frequency defined by user
+ * and clipped_freq is the maximum that thermal constraints
+ * allow.
+ *
+ * If clipped_freq is lower than policy->max, then we need to
+ * readjust policy->max.
+ *
+ * But, if clipped_freq is greater than policy->max, we don't
+ * need to do anything.
+ */
+ clipped_freq = cpufreq_dev->clipped_freq;
- if (policy->max != max_freq)
- cpufreq_verify_within_limits(policy, 0,
- max_freq);
- }
- mutex_unlock(&cooling_cpufreq_lock);
+ if (policy->max > clipped_freq)
+ cpufreq_verify_within_limits(policy, 0, clipped_freq);
break;
- default:
- return NOTIFY_DONE;
}
+ mutex_unlock(&cooling_list_lock);
return NOTIFY_OK;
}
@@ -519,7 +528,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
clip_freq = cpufreq_device->freq_table[state];
cpufreq_device->cpufreq_state = state;
- cpufreq_device->cpufreq_val = clip_freq;
+ cpufreq_device->clipped_freq = clip_freq;
cpufreq_update_policy(cpu);
@@ -861,17 +870,19 @@ __cpufreq_cooling_register(struct device_node *np,
pr_debug("%s: freq:%u KHz\n", __func__, freq);
}
- cpufreq_dev->cpufreq_val = cpufreq_dev->freq_table[0];
+ cpufreq_dev->clipped_freq = cpufreq_dev->freq_table[0];
cpufreq_dev->cool_dev = cool_dev;
mutex_lock(&cooling_cpufreq_lock);
+ mutex_lock(&cooling_list_lock);
+ list_add(&cpufreq_dev->node, &cpufreq_dev_list);
+ mutex_unlock(&cooling_list_lock);
+
/* Register the notifier for first cpufreq cooling device */
- if (list_empty(&cpufreq_dev_list))
+ if (!cpufreq_dev_count++)
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);
- list_add(&cpufreq_dev->node, &cpufreq_dev_list);
-
mutex_unlock(&cooling_cpufreq_lock);
return cool_dev;
@@ -1013,13 +1024,17 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
return;
cpufreq_dev = cdev->devdata;
- mutex_lock(&cooling_cpufreq_lock);
- list_del(&cpufreq_dev->node);
/* Unregister the notifier for the last cpufreq cooling device */
- if (list_empty(&cpufreq_dev_list))
+ mutex_lock(&cooling_cpufreq_lock);
+ if (!--cpufreq_dev_count)
cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);
+
+ mutex_lock(&cooling_list_lock);
+ list_del(&cpufreq_dev->node);
+ mutex_unlock(&cooling_list_lock);
+
mutex_unlock(&cooling_cpufreq_lock);
thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
diff --git a/drivers/thermal/power_allocator.c b/drivers/thermal/power_allocator.c
index 63a448f9d93b..7006860f2f36 100644
--- a/drivers/thermal/power_allocator.c
+++ b/drivers/thermal/power_allocator.c
@@ -334,7 +334,7 @@ static int allocate_power(struct thermal_zone_device *tz,
max_allocatable_power, current_temp,
(s32)control_temp - (s32)current_temp);
- devm_kfree(&tz->device, req_power);
+ kfree(req_power);
unlock:
mutex_unlock(&tz->lock);
@@ -426,7 +426,7 @@ static int power_allocator_bind(struct thermal_zone_device *tz)
return -EINVAL;
}
- params = devm_kzalloc(&tz->device, sizeof(*params), GFP_KERNEL);
+ params = kzalloc(sizeof(*params), GFP_KERNEL);
if (!params)
return -ENOMEM;
@@ -468,14 +468,14 @@ static int power_allocator_bind(struct thermal_zone_device *tz)
return 0;
free:
- devm_kfree(&tz->device, params);
+ kfree(params);
return ret;
}
static void power_allocator_unbind(struct thermal_zone_device *tz)
{
dev_dbg(&tz->device, "Unbinding from thermal zone %d\n", tz->id);
- devm_kfree(&tz->device, tz->governor_data);
+ kfree(tz->governor_data);
tz->governor_data = NULL;
}