summaryrefslogtreecommitdiffstats
path: root/drivers/power/charger-manager.c
diff options
context:
space:
mode:
authorJoe Perches <joe@perches.com>2013-06-06 18:25:12 -0700
committerAnton Vorontsov <anton@enomsg.org>2013-06-09 10:07:36 -0700
commite5409cbd8c0bf44f65e7528635cf05ed298e0c61 (patch)
treebb5bea82e368b4fbeb29d2cda3d50e74626bcbb0 /drivers/power/charger-manager.c
parente24142178fc2f60824af4312d326edacdcd667a3 (diff)
downloadlinux-e5409cbd8c0bf44f65e7528635cf05ed298e0c61.tar.bz2
charger-manager: Add missing newlines, fix a couple of typos, add pr_fmt
Make sure that dev_<level> calls are newline terminated. Add #define pr_fmt(fmt) KBUILD_MODNAME ": " fmt to prefix all pr_<level> calls with "charger-manager: " Fix a couple of typos. Fix formats with terminating n that should be \n. Coalesce formats for easier grep. Align arguments to open parenthesis for these dev_<level> calls. Add missing spaces after coalescing multiple string segments. Signed-off-by: Joe Perches <joe@perches.com> Acked-by: Kees Cook <keescook@chromium.org> Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Diffstat (limited to 'drivers/power/charger-manager.c')
-rw-r--r--drivers/power/charger-manager.c137
1 files changed, 57 insertions, 80 deletions
diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
index 98de1ddce458..ba420292628e 100644
--- a/drivers/power/charger-manager.c
+++ b/drivers/power/charger-manager.c
@@ -12,6 +12,8 @@
* published by the Free Software Foundation.
**/
+#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
+
#include <linux/io.h>
#include <linux/module.h>
#include <linux/irq.h>
@@ -195,8 +197,8 @@ static bool is_charging(struct charger_manager *cm)
cm->charger_stat[i],
POWER_SUPPLY_PROP_ONLINE, &val);
if (ret) {
- dev_warn(cm->dev, "Cannot read ONLINE value from %s.\n",
- cm->desc->psy_charger_stat[i]);
+ dev_warn(cm->dev, "Cannot read ONLINE value from %s\n",
+ cm->desc->psy_charger_stat[i]);
continue;
}
if (val.intval == 0)
@@ -210,8 +212,8 @@ static bool is_charging(struct charger_manager *cm)
cm->charger_stat[i],
POWER_SUPPLY_PROP_STATUS, &val);
if (ret) {
- dev_warn(cm->dev, "Cannot read STATUS value from %s.\n",
- cm->desc->psy_charger_stat[i]);
+ dev_warn(cm->dev, "Cannot read STATUS value from %s\n",
+ cm->desc->psy_charger_stat[i]);
continue;
}
if (val.intval == POWER_SUPPLY_STATUS_FULL ||
@@ -289,7 +291,7 @@ static bool is_polling_required(struct charger_manager *cm)
return is_charging(cm);
default:
dev_warn(cm->dev, "Incorrect polling_mode (%d)\n",
- cm->desc->polling_mode);
+ cm->desc->polling_mode);
}
return false;
@@ -331,9 +333,8 @@ static int try_charger_enable(struct charger_manager *cm, bool enable)
err = regulator_enable(desc->charger_regulators[i].consumer);
if (err < 0) {
- dev_warn(cm->dev,
- "Cannot enable %s regulator\n",
- desc->charger_regulators[i].regulator_name);
+ dev_warn(cm->dev, "Cannot enable %s regulator\n",
+ desc->charger_regulators[i].regulator_name);
}
}
} else {
@@ -350,9 +351,8 @@ static int try_charger_enable(struct charger_manager *cm, bool enable)
err = regulator_disable(desc->charger_regulators[i].consumer);
if (err < 0) {
- dev_warn(cm->dev,
- "Cannot disable %s regulator\n",
- desc->charger_regulators[i].regulator_name);
+ dev_warn(cm->dev, "Cannot disable %s regulator\n",
+ desc->charger_regulators[i].regulator_name);
}
}
@@ -365,9 +365,8 @@ static int try_charger_enable(struct charger_manager *cm, bool enable)
desc->charger_regulators[i].consumer)) {
regulator_force_disable(
desc->charger_regulators[i].consumer);
- dev_warn(cm->dev,
- "Disable regulator(%s) forcibly.\n",
- desc->charger_regulators[i].regulator_name);
+ dev_warn(cm->dev, "Disable regulator(%s) forcibly\n",
+ desc->charger_regulators[i].regulator_name);
}
}
}
@@ -450,7 +449,7 @@ static void uevent_notify(struct charger_manager *cm, const char *event)
strncpy(env_str, event, UEVENT_BUF_SIZE);
kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE);
- dev_info(cm->dev, "%s", event);
+ dev_info(cm->dev, "%s\n", event);
}
/**
@@ -478,7 +477,7 @@ static void fullbatt_vchk(struct work_struct *work)
err = get_batt_uV(cm, &batt_uV);
if (err) {
- dev_err(cm->dev, "%s: get_batt_uV error(%d).\n", __func__, err);
+ dev_err(cm->dev, "%s: get_batt_uV error(%d)\n", __func__, err);
return;
}
@@ -486,7 +485,7 @@ static void fullbatt_vchk(struct work_struct *work)
if (diff < 0)
return;
- dev_info(cm->dev, "VBATT dropped %duV after full-batt.\n", diff);
+ dev_info(cm->dev, "VBATT dropped %duV after full-batt\n", diff);
if (diff > desc->fullbatt_vchkdrop_uV) {
try_charger_restart(cm);
@@ -519,7 +518,7 @@ static int check_charging_duration(struct charger_manager *cm)
duration = curr - cm->charging_start_time;
if (duration > desc->charging_max_duration_ms) {
- dev_info(cm->dev, "Charging duration exceed %lldms",
+ dev_info(cm->dev, "Charging duration exceed %lldms\n",
desc->charging_max_duration_ms);
uevent_notify(cm, "Discharging");
try_charger_enable(cm, false);
@@ -530,9 +529,9 @@ static int check_charging_duration(struct charger_manager *cm)
if (duration > desc->charging_max_duration_ms &&
is_ext_pwr_online(cm)) {
- dev_info(cm->dev, "DisCharging duration exceed %lldms",
+ dev_info(cm->dev, "Discharging duration exceed %lldms\n",
desc->discharging_max_duration_ms);
- uevent_notify(cm, "Recharing");
+ uevent_notify(cm, "Recharging");
try_charger_enable(cm, true);
ret = true;
}
@@ -579,7 +578,7 @@ static bool _cm_monitor(struct charger_manager *cm)
*/
} else if (!cm->emergency_stop && check_charging_duration(cm)) {
dev_dbg(cm->dev,
- "Charging/Discharging duration is out of range");
+ "Charging/Discharging duration is out of range\n");
/*
* Check dropped voltage of battery. If battery voltage is more
* dropped than fullbatt_vchkdrop_uV after fully charged state,
@@ -595,7 +594,7 @@ static bool _cm_monitor(struct charger_manager *cm)
*/
} else if (!cm->emergency_stop && is_full_charged(cm) &&
cm->charger_enabled) {
- dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged.\n");
+ dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged\n");
uevent_notify(cm, default_event_names[CM_EVENT_BATT_FULL]);
try_charger_enable(cm, false);
@@ -725,7 +724,7 @@ static void fullbatt_handler(struct charger_manager *cm)
cm->fullbatt_vchk_jiffies_at = 1;
out:
- dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged.\n");
+ dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged\n");
uevent_notify(cm, default_event_names[CM_EVENT_BATT_FULL]);
}
@@ -972,7 +971,7 @@ static bool cm_setup_timer(void)
mutex_unlock(&cm_list_mtx);
if (wakeup_ms < UINT_MAX && wakeup_ms > 0) {
- pr_info("Charger Manager wakeup timer: %u ms.\n", wakeup_ms);
+ pr_info("Charger Manager wakeup timer: %u ms\n", wakeup_ms);
if (rtc_dev) {
struct rtc_wkalrm tmp;
unsigned long time, now;
@@ -1005,8 +1004,7 @@ static bool cm_setup_timer(void)
ret = false;
}
- pr_info("Waking up after %lu secs.\n",
- time - now);
+ pr_info("Waking up after %lu secs\n", time - now);
rtc_time_to_tm(time, &tmp.time);
rtc_set_alarm(rtc_dev, &tmp);
@@ -1101,7 +1099,7 @@ int setup_charger_manager(struct charger_global_desc *gd)
g_desc = NULL;
if (!gd->rtc_only_wakeup) {
- pr_err("The callback rtc_only_wakeup is not given.\n");
+ pr_err("The callback rtc_only_wakeup is not given\n");
return -EINVAL;
}
@@ -1112,7 +1110,7 @@ int setup_charger_manager(struct charger_global_desc *gd)
/* Retry at probe. RTC may be not registered yet */
}
} else {
- pr_warn("No wakeup timer is given for charger manager."
+ pr_warn("No wakeup timer is given for charger manager. "
"In-suspend monitoring won't work.\n");
}
@@ -1138,13 +1136,13 @@ static void charger_extcon_work(struct work_struct *work)
cable->min_uA, cable->max_uA);
if (ret < 0) {
pr_err("Cannot set current limit of %s (%s)\n",
- cable->charger->regulator_name, cable->name);
+ cable->charger->regulator_name, cable->name);
return;
}
pr_info("Set current limit of %s : %duA ~ %duA\n",
- cable->charger->regulator_name,
- cable->min_uA, cable->max_uA);
+ cable->charger->regulator_name,
+ cable->min_uA, cable->max_uA);
}
try_charger_enable(cable->cm, cable->attached);
@@ -1210,9 +1208,8 @@ static int charger_extcon_init(struct charger_manager *cm,
ret = extcon_register_interest(&cable->extcon_dev,
cable->extcon_name, cable->name, &cable->nb);
if (ret < 0) {
- pr_info("Cannot register extcon_dev for %s(cable: %s).\n",
- cable->extcon_name,
- cable->name);
+ pr_info("Cannot register extcon_dev for %s(cable: %s)\n",
+ cable->extcon_name, cable->name);
ret = -EINVAL;
}
@@ -1243,8 +1240,8 @@ static int charger_manager_register_extcon(struct charger_manager *cm)
charger->consumer = regulator_get(cm->dev,
charger->regulator_name);
if (charger->consumer == NULL) {
- dev_err(cm->dev, "Cannot find charger(%s)n",
- charger->regulator_name);
+ dev_err(cm->dev, "Cannot find charger(%s)\n",
+ charger->regulator_name);
ret = -EINVAL;
goto err;
}
@@ -1255,8 +1252,8 @@ static int charger_manager_register_extcon(struct charger_manager *cm)
ret = charger_extcon_init(cm, cable);
if (ret < 0) {
- dev_err(cm->dev, "Cannot initialize charger(%s)n",
- charger->regulator_name);
+ dev_err(cm->dev, "Cannot initialize charger(%s)\n",
+ charger->regulator_name);
goto err;
}
cable->charger = charger;
@@ -1347,10 +1344,8 @@ static ssize_t charger_externally_control_store(struct device *dev,
}
} else {
dev_warn(cm->dev,
- "'%s' regulator should be controlled "
- "in charger-manager because charger-manager "
- "must need at least one charger for charging\n",
- charger->regulator_name);
+ "'%s' regulator should be controlled in charger-manager because charger-manager must need at least one charger for charging\n",
+ charger->regulator_name);
}
return count;
@@ -1386,8 +1381,6 @@ static int charger_manager_register_sysfs(struct charger_manager *cm)
snprintf(buf, 10, "charger.%d", i);
str = kzalloc(sizeof(char) * (strlen(buf) + 1), GFP_KERNEL);
if (!str) {
- dev_err(cm->dev, "Cannot allocate memory: %s\n",
- charger->regulator_name);
ret = -ENOMEM;
goto err;
}
@@ -1423,26 +1416,21 @@ static int charger_manager_register_sysfs(struct charger_manager *cm)
!chargers_externally_control)
chargers_externally_control = 0;
- dev_info(cm->dev, "'%s' regulator's externally_control"
- "is %d\n", charger->regulator_name,
- charger->externally_control);
+ dev_info(cm->dev, "'%s' regulator's externally_control is %d\n",
+ charger->regulator_name, charger->externally_control);
ret = sysfs_create_group(&cm->charger_psy.dev->kobj,
&charger->attr_g);
if (ret < 0) {
- dev_err(cm->dev, "Cannot create sysfs entry"
- "of %s regulator\n",
- charger->regulator_name);
+ dev_err(cm->dev, "Cannot create sysfs entry of %s regulator\n",
+ charger->regulator_name);
ret = -EINVAL;
goto err;
}
}
if (chargers_externally_control) {
- dev_err(cm->dev, "Cannot register regulator because "
- "charger-manager must need at least "
- "one charger for charging battery\n");
-
+ dev_err(cm->dev, "Cannot register regulator because charger-manager must need at least one charger for charging battery\n");
ret = -EINVAL;
goto err;
}
@@ -1463,7 +1451,7 @@ static int charger_manager_probe(struct platform_device *pdev)
rtc_dev = rtc_class_open(g_desc->rtc_name);
if (IS_ERR_OR_NULL(rtc_dev)) {
rtc_dev = NULL;
- dev_err(&pdev->dev, "Cannot get RTC %s.\n",
+ dev_err(&pdev->dev, "Cannot get RTC %s\n",
g_desc->rtc_name);
ret = -ENODEV;
goto err_alloc;
@@ -1471,14 +1459,13 @@ static int charger_manager_probe(struct platform_device *pdev)
}
if (!desc) {
- dev_err(&pdev->dev, "No platform data (desc) found.\n");
+ dev_err(&pdev->dev, "No platform data (desc) found\n");
ret = -ENODEV;
goto err_alloc;
}
cm = kzalloc(sizeof(struct charger_manager), GFP_KERNEL);
if (!cm) {
- dev_err(&pdev->dev, "Cannot allocate memory.\n");
ret = -ENOMEM;
goto err_alloc;
}
@@ -1487,7 +1474,6 @@ static int charger_manager_probe(struct platform_device *pdev)
cm->dev = &pdev->dev;
cm->desc = kmemdup(desc, sizeof(struct charger_desc), GFP_KERNEL);
if (!cm->desc) {
- dev_err(&pdev->dev, "Cannot allocate memory.\n");
ret = -ENOMEM;
goto err_alloc_desc;
}
@@ -1498,33 +1484,28 @@ static int charger_manager_probe(struct platform_device *pdev)
* Users may intentionally ignore those two features.
*/
if (desc->fullbatt_uV == 0) {
- dev_info(&pdev->dev, "Ignoring full-battery voltage threshold"
- " as it is not supplied.");
+ dev_info(&pdev->dev, "Ignoring full-battery voltage threshold as it is not supplied\n");
}
if (!desc->fullbatt_vchkdrop_ms || !desc->fullbatt_vchkdrop_uV) {
- dev_info(&pdev->dev, "Disabling full-battery voltage drop "
- "checking mechanism as it is not supplied.");
+ dev_info(&pdev->dev, "Disabling full-battery voltage drop checking mechanism as it is not supplied\n");
desc->fullbatt_vchkdrop_ms = 0;
desc->fullbatt_vchkdrop_uV = 0;
}
if (desc->fullbatt_soc == 0) {
- dev_info(&pdev->dev, "Ignoring full-battery soc(state of"
- " charge) threshold as it is not"
- " supplied.");
+ dev_info(&pdev->dev, "Ignoring full-battery soc(state of charge) threshold as it is not supplied\n");
}
if (desc->fullbatt_full_capacity == 0) {
- dev_info(&pdev->dev, "Ignoring full-battery full capacity"
- " threshold as it is not supplied.");
+ dev_info(&pdev->dev, "Ignoring full-battery full capacity threshold as it is not supplied\n");
}
if (!desc->charger_regulators || desc->num_charger_regulators < 1) {
ret = -EINVAL;
- dev_err(&pdev->dev, "charger_regulators undefined.\n");
+ dev_err(&pdev->dev, "charger_regulators undefined\n");
goto err_no_charger;
}
if (!desc->psy_charger_stat || !desc->psy_charger_stat[0]) {
- dev_err(&pdev->dev, "No power supply defined.\n");
+ dev_err(&pdev->dev, "No power supply defined\n");
ret = -EINVAL;
goto err_no_charger_stat;
}
@@ -1544,9 +1525,8 @@ static int charger_manager_probe(struct platform_device *pdev)
cm->charger_stat[i] = power_supply_get_by_name(
desc->psy_charger_stat[i]);
if (!cm->charger_stat[i]) {
- dev_err(&pdev->dev, "Cannot find power supply "
- "\"%s\"\n",
- desc->psy_charger_stat[i]);
+ dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n",
+ desc->psy_charger_stat[i]);
ret = -ENODEV;
goto err_chg_stat;
}
@@ -1555,7 +1535,7 @@ static int charger_manager_probe(struct platform_device *pdev)
cm->fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge);
if (!cm->fuel_gauge) {
dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n",
- desc->psy_fuel_gauge);
+ desc->psy_fuel_gauge);
ret = -ENODEV;
goto err_chg_stat;
}
@@ -1575,9 +1555,7 @@ static int charger_manager_probe(struct platform_device *pdev)
if (!desc->charging_max_duration_ms ||
!desc->discharging_max_duration_ms) {
- dev_info(&pdev->dev, "Cannot limit charging duration "
- "checking mechanism to prevent overcharge/overheat "
- "and control discharging duration");
+ dev_info(&pdev->dev, "Cannot limit charging duration checking mechanism to prevent overcharge/overheat and control discharging duration\n");
desc->charging_max_duration_ms = 0;
desc->discharging_max_duration_ms = 0;
}
@@ -1598,7 +1576,6 @@ static int charger_manager_probe(struct platform_device *pdev)
NUM_CHARGER_PSY_OPTIONAL),
GFP_KERNEL);
if (!cm->charger_psy.properties) {
- dev_err(&pdev->dev, "Cannot allocate for psy properties.\n");
ret = -ENOMEM;
goto err_chg_stat;
}
@@ -1636,8 +1613,8 @@ static int charger_manager_probe(struct platform_device *pdev)
ret = power_supply_register(NULL, &cm->charger_psy);
if (ret) {
- dev_err(&pdev->dev, "Cannot register charger-manager with"
- " name \"%s\".\n", cm->charger_psy.name);
+ dev_err(&pdev->dev, "Cannot register charger-manager with name \"%s\"\n",
+ cm->charger_psy.name);
goto err_register;
}
@@ -1948,7 +1925,7 @@ void cm_notify_event(struct power_supply *psy, enum cm_event_types type,
uevent_notify(cm, msg ? msg : default_event_names[type]);
break;
default:
- dev_err(cm->dev, "%s type not specified.\n", __func__);
+ dev_err(cm->dev, "%s: type not specified\n", __func__);
break;
}
}