diff options
author | David S. Miller <davem@davemloft.net> | 2018-05-18 13:00:08 -0400 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2018-05-18 13:00:08 -0400 |
commit | 3888ea4e2f1fb2f61e5418adf4b8332107ac0c8f (patch) | |
tree | 93c4bd644e25a6e3c531ecba1f9c4138525afeb4 /drivers/net/ethernet/mellanox/mlx5/core/fs_core.c | |
parent | 2c47a65b7009eb21f16f1d258b682ee38cff5186 (diff) | |
parent | 10ff5359f883412728ba816046ee3a696625ca02 (diff) | |
download | linux-3888ea4e2f1fb2f61e5418adf4b8332107ac0c8f.tar.bz2 |
Merge tag 'mlx5-updates-2018-05-17' of git://git.kernel.org/pub/scm/linux/kernel/git/mellanox/linux
Saeed Mahameed says:
====================
mlx5-updates-2018-05-17
mlx5 core dirver updates for both net-next and rdma-next branches.
From Christophe JAILLET, first three patche to use kvfree where needed.
From: Or Gerlitz <ogerlitz@mellanox.com>
Next six patches from Roi and Co adds support for merged
sriov e-switch which comes to serve cases where both PFs, VFs set
on them and both uplinks are to be used in single v-switch SW model.
When merged e-switch is supported, the per-port e-switch is logically
merged into one e-switch that spans both physical ports and all the VFs.
This model allows to offload TC eswitch rules between VFs belonging
to different PFs (and hence have different eswitch affinity), it also
sets the some of the foundations needed for uplink LAG support.
====================
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/ethernet/mellanox/mlx5/core/fs_core.c')
-rw-r--r-- | drivers/net/ethernet/mellanox/mlx5/core/fs_core.c | 12 |
1 files changed, 11 insertions, 1 deletions
diff --git a/drivers/net/ethernet/mellanox/mlx5/core/fs_core.c b/drivers/net/ethernet/mellanox/mlx5/core/fs_core.c index c39c1692e674..806e95523f9e 100644 --- a/drivers/net/ethernet/mellanox/mlx5/core/fs_core.c +++ b/drivers/net/ethernet/mellanox/mlx5/core/fs_core.c @@ -1374,6 +1374,8 @@ static int create_auto_flow_group(struct mlx5_flow_table *ft, struct mlx5_core_dev *dev = get_dev(&ft->node); int inlen = MLX5_ST_SZ_BYTES(create_flow_group_in); void *match_criteria_addr; + u8 src_esw_owner_mask_on; + void *misc; int err; u32 *in; @@ -1386,6 +1388,14 @@ static int create_auto_flow_group(struct mlx5_flow_table *ft, MLX5_SET(create_flow_group_in, in, start_flow_index, fg->start_index); MLX5_SET(create_flow_group_in, in, end_flow_index, fg->start_index + fg->max_ftes - 1); + + misc = MLX5_ADDR_OF(fte_match_param, fg->mask.match_criteria, + misc_parameters); + src_esw_owner_mask_on = !!MLX5_GET(fte_match_set_misc, misc, + source_eswitch_owner_vhca_id); + MLX5_SET(create_flow_group_in, in, + source_eswitch_owner_vhca_id_valid, src_esw_owner_mask_on); + match_criteria_addr = MLX5_ADDR_OF(create_flow_group_in, in, match_criteria); memcpy(match_criteria_addr, fg->mask.match_criteria, @@ -1406,7 +1416,7 @@ static bool mlx5_flow_dests_cmp(struct mlx5_flow_destination *d1, { if (d1->type == d2->type) { if ((d1->type == MLX5_FLOW_DESTINATION_TYPE_VPORT && - d1->vport_num == d2->vport_num) || + d1->vport.num == d2->vport.num) || (d1->type == MLX5_FLOW_DESTINATION_TYPE_FLOW_TABLE && d1->ft == d2->ft) || (d1->type == MLX5_FLOW_DESTINATION_TYPE_TIR && |