summaryrefslogtreecommitdiffstats
path: root/drivers/net/dsa
diff options
context:
space:
mode:
authorVladimir Oltean <vladimir.oltean@nxp.com>2020-10-31 12:29:16 +0200
committerJakub Kicinski <kuba@kernel.org>2020-11-02 17:09:07 -0800
commit9a72068080f14a9f249507eb171df26c912757dc (patch)
tree6d2af69b39fc42949b8099688599c57556b546d8 /drivers/net/dsa
parent2f0402fedf20cc97b90837f6a9e2f5dc670afd4d (diff)
downloadlinux-9a72068080f14a9f249507eb171df26c912757dc.tar.bz2
net: dsa: felix: improve the workaround for multiple native VLANs on NPI port
After the good discussion with Florian from here: https://lore.kernel.org/netdev/20200911000337.htwr366ng3nc3a7d@skbuf/ I realized that the VLAN settings on the NPI port (the hardware "CPU port", in DSA parlance) don't actually make any difference, because that port is hardcoded in hardware to use what mv88e6xxx would call "unmodified" egress policy for VLANs. So earlier patch 183be6f967fe ("net: dsa: felix: send VLANs on CPU port as egress-tagged") was incorrect in the sense that it didn't actually make the VLANs be sent on the NPI port as egress-tagged. It only made ocelot_port_set_native_vlan shut up. Now that we have moved the check from ocelot_port_set_native_vlan to ocelot_vlan_prepare, we can simply shunt ocelot_vlan_prepare from DSA, and avoid calling it. This is the correct way to deal with things, because the NPI port configuration is DSA-specific, so the ocelot switch library should not have the check for multiple native VLANs refined in any way, it is correct the way it is. Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Diffstat (limited to 'drivers/net/dsa')
-rw-r--r--drivers/net/dsa/ocelot/felix.c14
1 files changed, 11 insertions, 3 deletions
diff --git a/drivers/net/dsa/ocelot/felix.c b/drivers/net/dsa/ocelot/felix.c
index 3848f6bc922b..ada75fa15861 100644
--- a/drivers/net/dsa/ocelot/felix.c
+++ b/drivers/net/dsa/ocelot/felix.c
@@ -119,6 +119,17 @@ static int felix_vlan_prepare(struct dsa_switch *ds, int port,
u16 vid, flags = vlan->flags;
int err;
+ /* Ocelot switches copy frames as-is to the CPU, so the flags:
+ * egress-untagged or not, pvid or not, make no difference. This
+ * behavior is already better than what DSA just tries to approximate
+ * when it installs the VLAN with the same flags on the CPU port.
+ * Just accept any configuration, and don't let ocelot deny installing
+ * multiple native VLANs on the NPI port, because the switch doesn't
+ * look at the port tag settings towards the NPI interface anyway.
+ */
+ if (port == ocelot->npi)
+ return 0;
+
for (vid = vlan->vid_begin; vid <= vlan->vid_end; vid++) {
err = ocelot_vlan_prepare(ocelot, port, vid,
flags & BRIDGE_VLAN_INFO_PVID,
@@ -146,9 +157,6 @@ static void felix_vlan_add(struct dsa_switch *ds, int port,
u16 vid;
int err;
- if (dsa_is_cpu_port(ds, port))
- flags &= ~BRIDGE_VLAN_INFO_UNTAGGED;
-
for (vid = vlan->vid_begin; vid <= vlan->vid_end; vid++) {
err = ocelot_vlan_add(ocelot, port, vid,
flags & BRIDGE_VLAN_INFO_PVID,