diff options
author | Shah Dharati <dharshah@amd.com> | 2022-05-31 09:58:12 -0400 |
---|---|---|
committer | Alex Deucher <alexander.deucher@amd.com> | 2022-06-14 21:38:40 -0400 |
commit | b840b64bc8ed3fc46f6d6aa7f97c43862a33bea5 (patch) | |
tree | 7fecfb58dd593472757c0710751885bb3037df7f /drivers/gpu/drm/amd/display/modules | |
parent | c443514a7d6d648bc497efbe502e2a49738b94de (diff) | |
download | linux-b840b64bc8ed3fc46f6d6aa7f97c43862a33bea5.tar.bz2 |
drm/amd/display: Fix monitor flash issue
[Why & How]
For a some specific monitors, when connected on boot or hot plug,
monitor flash for 1/2 seconds can happen during first HDCP query
operation. Ading some delay in the init sequence for these monitors
fixes the issue, so it is implemented as monitor specific patch.
Co-authored-by: Shah Dharati <dharshah@amd.com>
Reviewed-by: Hansen Dsouza <Hansen.Dsouza@amd.com>
Reviewed-by: Nicholas Kazlauskas <Nicholas.Kazlauskas@amd.com>
Acked-by: Hamza Mahfooz <hamza.mahfooz@amd.com>
Signed-off-by: Shah Dharati <dharshah@amd.com>
Tested-by: Daniel Wheeler <daniel.wheeler@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
Diffstat (limited to 'drivers/gpu/drm/amd/display/modules')
-rw-r--r-- | drivers/gpu/drm/amd/display/modules/hdcp/hdcp2_transition.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/gpu/drm/amd/display/modules/hdcp/hdcp2_transition.c b/drivers/gpu/drm/amd/display/modules/hdcp/hdcp2_transition.c index 1f4095b26409..c5f6c11de7e5 100644 --- a/drivers/gpu/drm/amd/display/modules/hdcp/hdcp2_transition.c +++ b/drivers/gpu/drm/amd/display/modules/hdcp/hdcp2_transition.c @@ -524,7 +524,7 @@ enum mod_hdcp_status mod_hdcp_hdcp2_dp_transition(struct mod_hdcp *hdcp, set_watchdog_in_ms(hdcp, 3000, output); set_state_id(hdcp, output, D2_A6_WAIT_FOR_RX_ID_LIST); } else { - callback_in_ms(0, output); + callback_in_ms(1, output); set_state_id(hdcp, output, D2_SEND_CONTENT_STREAM_TYPE); } break; |