We need the IIO changes in here for future patches to build on. Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/arm/CCN.txt16
-rw-r--r--Documentation/cpu-freq/cpufreq-stats.txt2
-rw-r--r--Documentation/i2c/slave-interface5
3 files changed, 16 insertions, 7 deletions
diff --git a/Documentation/arm/CCN.txt b/Documentation/arm/CCN.txt
index ffca443a19b4..15cdb7bc57c3 100644
--- a/Documentation/arm/CCN.txt
+++ b/Documentation/arm/CCN.txt
@@ -18,13 +18,17 @@ and config2 fields of the perf_event_attr structure. The "events"
directory provides configuration templates for all documented
events, that can be used with perf tool. For example "xp_valid_flit"
is an equivalent of "type=0x8,event=0x4". Other parameters must be
-explicitly specified. For events originating from device, "node"
-defines its index. All crosspoint events require "xp" (index),
-"port" (device port number) and "vc" (virtual channel ID) and
-"dir" (direction). Watchpoints (special "event" value 0xfe) also
-require comparator values ("cmp_l" and "cmp_h") and "mask", being
-index of the comparator mask.
+explicitly specified.
+For events originating from device, "node" defines its index.
+
+Crosspoint PMU events require "xp" (index), "bus" (bus number)
+and "vc" (virtual channel ID).
+
+Crosspoint watchpoint-based events (special "event" value 0xfe)
+require "xp" and "vc" as as above plus "port" (device port index),
+"dir" (transmit/receive direction), comparator values ("cmp_l"
+and "cmp_h") and "mask", being index of the comparator mask.
Masks are defined separately from the event description
(due to limited number of the config values) in the "cmp_mask"
directory, with first 8 configurable by user and additional
diff --git a/Documentation/cpu-freq/cpufreq-stats.txt b/Documentation/cpu-freq/cpufreq-stats.txt
index fc647492e940..8d9773f23550 100644
--- a/Documentation/cpu-freq/cpufreq-stats.txt
+++ b/Documentation/cpu-freq/cpufreq-stats.txt
@@ -103,7 +103,7 @@ Config Main Menu
Power management options (ACPI, APM) --->
CPU Frequency scaling --->
[*] CPU Frequency scaling
- <*> CPU frequency translation statistics
+ [*] CPU frequency translation statistics
[*] CPU frequency translation statistics details
diff --git a/Documentation/i2c/slave-interface b/Documentation/i2c/slave-interface
index 80807adb8ded..7e2a228f21bc 100644
--- a/Documentation/i2c/slave-interface
+++ b/Documentation/i2c/slave-interface
@@ -145,6 +145,11 @@ If you want to add slave support to the bus driver:
* Catch the slave interrupts and send appropriate i2c_slave_events to the backend.
+Note that most hardware supports being master _and_ slave on the same bus. So,
+if you extend a bus driver, please make sure that the driver supports that as
+well. In almost all cases, slave support does not need to disable the master
+functionality.
+
Check the i2c-rcar driver as an example.