media: smiapp: Don't update sensor configuration during power-on init
The sensor configuration since it was previously powered off was not
changed, so no need to update the PLL configuration etc. What is necessary
though is to re-apply the configuration to the sensor's registers.
Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
-rw-r--r-- | drivers/media/i2c/smiapp/smiapp-core.c | 4 |
1 files changed, 0 insertions, 4 deletions
diff --git a/drivers/media/i2c/smiapp/smiapp-core.c b/drivers/media/i2c/smiapp/smiapp-core.c index 9986215fed89..1fad05583feb 100644 --- a/drivers/media/i2c/smiapp/smiapp-core.c +++ b/drivers/media/i2c/smiapp/smiapp-core.c @@ -1267,10 +1267,6 @@ static int smiapp_power_on(struct device *dev) rval = __v4l2_ctrl_handler_setup(&sensor->src->ctrl_handler); if (rval) goto out_cci_addr_fail; - - rval = smiapp_update_mode(sensor); - if (rval < 0) - goto out_cci_addr_fail; } mutex_unlock(&sensor->mutex); |