diff options
author | Viresh Kumar <viresh.kumar@linaro.org> | 2017-04-25 15:57:18 +0530 |
---|---|---|
committer | Eduardo Valentin <edubezval@gmail.com> | 2017-05-27 17:32:41 -0700 |
commit | ba76dd9ddd4046ece873444c2256e09afbd5d32e (patch) | |
tree | b4aabae630842b4b3eacd24375b10b079b80081e | |
parent | 02bacb21c6575ce408645ddb22fef44940d10257 (diff) | |
download | linux-ba76dd9ddd4046ece873444c2256e09afbd5d32e.tar.bz2 |
thermal: cpu_cooling: get rid of 'allowed_cpus'
'allowed_cpus' is a copy of policy->related_cpus and can be replaced by
it directly. At some places we are only concerned about online CPUs and
policy->cpus can be used there.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
-rw-r--r-- | drivers/thermal/cpu_cooling.c | 81 |
1 files changed, 25 insertions, 56 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index ce387f62c93e..94e7121817bf 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -74,7 +74,6 @@ struct power_table { * frequency. * @max_level: maximum cooling level. One less than total number of valid * cpufreq frequencies. - * @allowed_cpus: all the cpus involved for this cpufreq_cooling_device. * @node: list_head to link all cpufreq_cooling_device together. * @last_load: load measured by the latest call to cpufreq_get_requested_power() * @time_in_idle: previous reading of the absolute time that this cpu was idle @@ -97,7 +96,6 @@ struct cpufreq_cooling_device { unsigned int clipped_freq; unsigned int max_level; unsigned int *freq_table; /* In descending order */ - struct cpumask allowed_cpus; struct list_head node; u32 last_load; u64 *time_in_idle; @@ -161,7 +159,11 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, mutex_lock(&cooling_list_lock); list_for_each_entry(cpufreq_cdev, &cpufreq_cdev_list, node) { - if (!cpumask_test_cpu(policy->cpu, &cpufreq_cdev->allowed_cpus)) + /* + * A new copy of the policy is sent to the notifier and can't + * compare that directly. + */ + if (policy->cpu != cpufreq_cdev->policy->cpu) continue; /* @@ -304,7 +306,7 @@ static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev, * get_load() - get load for a cpu since last updated * @cpufreq_cdev: &struct cpufreq_cooling_device for this cpu * @cpu: cpu number - * @cpu_idx: index of the cpu in cpufreq_cdev->allowed_cpus + * @cpu_idx: index of the cpu in time_in_idle* * * Return: The average load of cpu @cpu in percentage since this * function was last called. @@ -351,7 +353,7 @@ static int get_static_power(struct cpufreq_cooling_device *cpufreq_cdev, { struct dev_pm_opp *opp; unsigned long voltage; - struct cpumask *cpumask = &cpufreq_cdev->allowed_cpus; + struct cpumask *cpumask = cpufreq_cdev->policy->related_cpus; unsigned long freq_hz = freq * 1000; if (!cpufreq_cdev->plat_get_static_power || !cpufreq_cdev->cpu_dev) { @@ -468,7 +470,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, cpufreq_cdev->cpufreq_state = state; cpufreq_cdev->clipped_freq = clip_freq; - cpufreq_update_policy(cpumask_any(&cpufreq_cdev->allowed_cpus)); + cpufreq_update_policy(cpufreq_cdev->policy->cpu); return 0; } @@ -504,28 +506,18 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev, int i = 0, cpu, ret; u32 static_power, dynamic_power, total_load = 0; struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; + struct cpufreq_policy *policy = cpufreq_cdev->policy; u32 *load_cpu = NULL; - cpu = cpumask_any_and(&cpufreq_cdev->allowed_cpus, cpu_online_mask); - - /* - * All the CPUs are offline, thus the requested power by - * the cdev is 0 - */ - if (cpu >= nr_cpu_ids) { - *power = 0; - return 0; - } - - freq = cpufreq_quick_get(cpu); + freq = cpufreq_quick_get(policy->cpu); if (trace_thermal_power_cpu_get_power_enabled()) { - u32 ncpus = cpumask_weight(&cpufreq_cdev->allowed_cpus); + u32 ncpus = cpumask_weight(policy->related_cpus); load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL); } - for_each_cpu(cpu, &cpufreq_cdev->allowed_cpus) { + for_each_cpu(cpu, policy->related_cpus) { u32 load; if (cpu_online(cpu)) @@ -550,9 +542,9 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev, } if (load_cpu) { - trace_thermal_power_cpu_get_power( - &cpufreq_cdev->allowed_cpus, - freq, load_cpu, i, dynamic_power, static_power); + trace_thermal_power_cpu_get_power(policy->related_cpus, freq, + load_cpu, i, dynamic_power, + static_power); kfree(load_cpu); } @@ -581,38 +573,22 @@ static int cpufreq_state2power(struct thermal_cooling_device *cdev, unsigned long state, u32 *power) { unsigned int freq, num_cpus; - cpumask_var_t cpumask; u32 static_power, dynamic_power; int ret; struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; - if (!alloc_cpumask_var(&cpumask, GFP_KERNEL)) - return -ENOMEM; - - cpumask_and(cpumask, &cpufreq_cdev->allowed_cpus, cpu_online_mask); - num_cpus = cpumask_weight(cpumask); - - /* None of our cpus are online, so no power */ - if (num_cpus == 0) { - *power = 0; - ret = 0; - goto out; - } + num_cpus = cpumask_weight(cpufreq_cdev->policy->cpus); freq = cpufreq_cdev->freq_table[state]; - if (!freq) { - ret = -EINVAL; - goto out; - } + if (!freq) + return -EINVAL; dynamic_power = cpu_freq_to_power(cpufreq_cdev, freq) * num_cpus; ret = get_static_power(cpufreq_cdev, tz, freq, &static_power); if (ret) - goto out; + return ret; *power = static_power + dynamic_power; -out: - free_cpumask_var(cpumask); return ret; } @@ -640,19 +616,14 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev, struct thermal_zone_device *tz, u32 power, unsigned long *state) { - unsigned int cpu, cur_freq, target_freq; + unsigned int cur_freq, target_freq; int ret; s32 dyn_power; u32 last_load, normalised_power, static_power; struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; + struct cpufreq_policy *policy = cpufreq_cdev->policy; - cpu = cpumask_any_and(&cpufreq_cdev->allowed_cpus, cpu_online_mask); - - /* None of our cpus are online */ - if (cpu >= nr_cpu_ids) - return -ENODEV; - - cur_freq = cpufreq_quick_get(cpu); + cur_freq = cpufreq_quick_get(policy->cpu); ret = get_static_power(cpufreq_cdev, tz, cur_freq, &static_power); if (ret) return ret; @@ -667,12 +638,12 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev, if (*state == THERMAL_CSTATE_INVALID) { dev_err_ratelimited(&cdev->device, "Failed to convert %dKHz for cpu %d into a cdev state\n", - target_freq, cpu); + target_freq, policy->cpu); return -EINVAL; } - trace_thermal_power_cpu_limit(&cpufreq_cdev->allowed_cpus, - target_freq, *state, power); + trace_thermal_power_cpu_limit(policy->related_cpus, target_freq, *state, + power); return 0; } @@ -786,8 +757,6 @@ __cpufreq_cooling_register(struct device_node *np, goto free_time_in_idle_timestamp; } - cpumask_copy(&cpufreq_cdev->allowed_cpus, policy->related_cpus); - if (capacitance) { cpufreq_cdev->plat_get_static_power = plat_static_func; |