1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
|
/*
* Amlogic Meson GXL Internal PHY Driver
*
* Copyright (C) 2015 Amlogic, Inc. All rights reserved.
* Copyright (C) 2016 BayLibre, SAS. All rights reserved.
* Author: Neil Armstrong <narmstrong@baylibre.com>
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; either version 2 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful, but WITHOUT
* ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or
* FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for
* more details.
*
*/
#include <linux/kernel.h>
#include <linux/module.h>
#include <linux/mii.h>
#include <linux/ethtool.h>
#include <linux/phy.h>
#include <linux/netdevice.h>
#include <linux/bitfield.h>
static int meson_gxl_config_init(struct phy_device *phydev)
{
/* Enable Analog and DSP register Bank access by */
phy_write(phydev, 0x14, 0x0000);
phy_write(phydev, 0x14, 0x0400);
phy_write(phydev, 0x14, 0x0000);
phy_write(phydev, 0x14, 0x0400);
/* Write Analog register 23 */
phy_write(phydev, 0x17, 0x8E0D);
phy_write(phydev, 0x14, 0x4417);
/* Enable fractional PLL */
phy_write(phydev, 0x17, 0x0005);
phy_write(phydev, 0x14, 0x5C1B);
/* Program fraction FR_PLL_DIV1 */
phy_write(phydev, 0x17, 0x029A);
phy_write(phydev, 0x14, 0x5C1D);
/* Program fraction FR_PLL_DIV1 */
phy_write(phydev, 0x17, 0xAAAA);
phy_write(phydev, 0x14, 0x5C1C);
return 0;
}
/* This function is provided to cope with the possible failures of this phy
* during aneg process. When aneg fails, the PHY reports that aneg is done
* but the value found in MII_LPA is wrong:
* - Early failures: MII_LPA is just 0x0001. if MII_EXPANSION reports that
* the link partner (LP) supports aneg but the LP never acked our base
* code word, it is likely that we never sent it to begin with.
* - Late failures: MII_LPA is filled with a value which seems to make sense
* but it actually is not what the LP is advertising. It seems that we
* can detect this using a magic bit in the WOL bank (reg 12 - bit 12).
* If this particular bit is not set when aneg is reported being done,
* it means MII_LPA is likely to be wrong.
*
* In both case, forcing a restart of the aneg process solve the problem.
* When this failure happens, the first retry is usually successful but,
* in some cases, it may take up to 6 retries to get a decent result
*/
static int meson_gxl_read_status(struct phy_device *phydev)
{
int ret, wol, lpa, exp;
if (phydev->autoneg == AUTONEG_ENABLE) {
ret = genphy_aneg_done(phydev);
if (ret < 0)
return ret;
else if (!ret)
goto read_status_continue;
/* Need to access WOL bank, make sure the access is open */
ret = phy_write(phydev, 0x14, 0x0000);
if (ret)
return ret;
ret = phy_write(phydev, 0x14, 0x0400);
if (ret)
return ret;
ret = phy_write(phydev, 0x14, 0x0000);
if (ret)
return ret;
ret = phy_write(phydev, 0x14, 0x0400);
if (ret)
return ret;
/* Request LPI_STATUS WOL register */
ret = phy_write(phydev, 0x14, 0x8D80);
if (ret)
return ret;
/* Read LPI_STATUS value */
wol = phy_read(phydev, 0x15);
if (wol < 0)
return wol;
lpa = phy_read(phydev, MII_LPA);
if (lpa < 0)
return lpa;
exp = phy_read(phydev, MII_EXPANSION);
if (exp < 0)
return exp;
if (!(wol & BIT(12)) ||
((exp & EXPANSION_NWAY) && !(lpa & LPA_LPACK))) {
/* Looks like aneg failed after all */
phydev_dbg(phydev, "LPA corruption - aneg restart\n");
return genphy_restart_aneg(phydev);
}
}
read_status_continue:
return genphy_read_status(phydev);
}
static struct phy_driver meson_gxl_phy[] = {
{
.phy_id = 0x01814400,
.phy_id_mask = 0xfffffff0,
.name = "Meson GXL Internal PHY",
.features = PHY_BASIC_FEATURES,
.flags = PHY_IS_INTERNAL,
.config_init = meson_gxl_config_init,
.aneg_done = genphy_aneg_done,
.read_status = meson_gxl_read_status,
.suspend = genphy_suspend,
.resume = genphy_resume,
},
};
static struct mdio_device_id __maybe_unused meson_gxl_tbl[] = {
{ 0x01814400, 0xfffffff0 },
{ }
};
module_phy_driver(meson_gxl_phy);
MODULE_DEVICE_TABLE(mdio, meson_gxl_tbl);
MODULE_DESCRIPTION("Amlogic Meson GXL Internal PHY driver");
MODULE_AUTHOR("Baoqi wang");
MODULE_AUTHOR("Neil Armstrong <narmstrong@baylibre.com>");
MODULE_LICENSE("GPL");
|