summaryrefslogtreecommitdiffstats
path: root/Documentation/w1/slaves/w1_therm.rst
blob: f1148181f53e3173f85c925dec5cf237b5a6d026 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
======================
Kernel driver w1_therm
======================

Supported chips:

  * Maxim ds18*20 based temperature sensors.
  * Maxim ds1825 based temperature sensors.

Author: Evgeniy Polyakov <johnpol@2ka.mipt.ru>


Description
-----------

w1_therm provides basic temperature conversion for ds18*20 devices, and the
ds28ea00 device.

Supported family codes:

====================	====
W1_THERM_DS18S20	0x10
W1_THERM_DS1822		0x22
W1_THERM_DS18B20	0x28
W1_THERM_DS1825		0x3B
W1_THERM_DS28EA00	0x42
====================	====

Support is provided through the sysfs w1_slave file. Each open and
read sequence will initiate a temperature conversion then provide two
lines of ASCII output. The first line contains the nine hex bytes
read along with a calculated crc value and YES or NO if it matched.
If the crc matched the returned values are retained. The second line
displays the retained values along with a temperature in millidegrees
Centigrade after t=.

Alternatively, temperature can be read using temperature sysfs, it
return only temperature in millidegrees Centigrade.

A bulk read of all devices on the bus could be done writing 'trigger'
in the therm_bulk_read sysfs entry at w1_bus_master level. This will
sent the convert command on all devices on the bus, and if parasite
powered devices are detected on the bus (and strong pullup is enable
in the module), it will drive the line high during the longer conversion
time required by parasited powered device on the line. Reading
therm_bulk_read will return 0 if no bulk conversion pending,
-1 if at least one sensor still in conversion, 1 if conversion is complete
but at least one sensor value has not been read yet. Result temperature is
then accessed by reading the temperature sysfs entry of each device, which
may return empty if conversion is still in progress. Note that if a bulk
read is sent but one sensor is not read immediately, the next access to
temperature on this device will return the temperature measured at the
time of issue of the bulk read command (not the current temperature).

A strong pullup will be applied during the conversion if required.

``conv_time`` sysfs entry is used to get current conversion time (read), and
adjust it (write). A temperature conversion time depends on the device type and
it's current resolution. Default conversion time is set by the driver according
to the device datasheet. A conversion time for many original device clones
deviate from datasheet specs. There are three options: 1) manually set the
correct conversion time by writing a value in milliseconds to ``conv_time``; 2)
auto measure and set a conversion time by writing ``1`` to
``conv_time``; 3) use ``features`` entry to enable poll for conversion
completion. Options 2, 3 can't be used in parasite power mode. To get back to
the default conversion time write ``0`` to ``conv_time``.

Writing a value between 9 and 12 to the sysfs w1_slave file will change the
precision of the sensor for the next readings. This value is in (volatile)
SRAM, so it is reset when the sensor gets power-cycled.

To store the current precision configuration into EEPROM, the value 0
has to be written to the sysfs w1_slave file. Since the EEPROM has a limited
amount of writes (>50k), this command should be used wisely.

Alternatively, resolution can be set or read (value from 9 to 12) using the
dedicated resolution sysfs entry on each device. This sysfs entry is not present
for devices not supporting this feature.

Some non-genuine DS18B20 chips are
fixed in 12-bit mode only, so the actual resolution is read back from the chip
and verified by the driver.

Note: Changing the resolution reverts the conversion time to default.

The write-only sysfs entry eeprom is an alternative for EEPROM operations:
  * 'save': will save device RAM to EEPROM
  * 'restore': will restore EEPROM data in device RAM.

ext_power syfs entry allow tho check the power status of each device.
  * '0': device parasite powered
  * '1': device externally powered

sysfs alarms allow read or write TH and TL (Temperature High an Low) alarms.
Values shall be space separated and in the device range (typical -55 degC
to 125 degC). Values are integer as they are store in a 8bit register in
the device. Lowest value is automatically put to TL.Once set, alarms could
be search at master level.

The module parameter strong_pullup can be set to 0 to disable the
strong pullup, 1 to enable autodetection or 2 to force strong pullup.
In case of autodetection, the driver will use the "READ POWER SUPPLY"
command to check if there are pariste powered devices on the bus.
If so, it will activate the master's strong pullup.
In case the detection of parasite devices using this command fails
(seems to be the case with some DS18S20) the strong pullup can
be force-enabled.

If the strong pullup is enabled, the master's strong pullup will be
driven when the conversion is taking place, provided the master driver
does support the strong pullup (or it falls back to a pullup
resistor).  The DS18b20 temperature sensor specification lists a
maximum current draw of 1.5mA and that a 5k pullup resistor is not
sufficient.  The strong pullup is designed to provide the additional
current required.

The DS28EA00 provides an additional two pins for implementing a sequence
detection algorithm.  This feature allows you to determine the physical
location of the chip in the 1-wire bus without needing pre-existing
knowledge of the bus ordering.  Support is provided through the sysfs
w1_seq file.  The file will contain a single line with an integer value
representing the device index in the bus starting at 0.

``features`` sysfs entry controls optional driver settings per device.
Insufficient power in parasite mode, line noise and insufficient conversion time
may lead to conversion failure. Original DS18B20 and some clones allow for
detection of invalid conversion. Write bit mask ``1`` to ``features`` to enable
checking the conversion success. If byte 6 of scratchpad memory is 0xC after
conversion and temperature reads 85.00 (powerup value) or 127.94 (insufficient
power), the driver returns a conversion error. Bit mask ``2`` enables poll for
conversion completion (normal power only) by generating read cycles on the bus
after conversion starts. In parasite power mode this feature is not available.
Feature bit masks may be combined (OR).