summaryrefslogtreecommitdiffstats
path: root/Documentation/networking/device_drivers/ti/cpsw_switchdev.txt
blob: 12855ab268b881ca2607353dcb6ed15b8f2087b7 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
* Texas Instruments CPSW switchdev based ethernet driver 2.0

- Port renaming
On older udev versions renaming of ethX to swXpY will not be automatically
supported
In order to rename via udev:
ip -d link show dev sw0p1 | grep switchid

SUBSYSTEM=="net", ACTION=="add", ATTR{phys_switch_id}==<switchid>, \
        ATTR{phys_port_name}!="", NAME="sw0$attr{phys_port_name}"


====================
# Dual mac mode
====================
- The new (cpsw_new.c) driver is operating in dual-emac mode by default, thus
working as 2 individual network interfaces. Main differences from legacy CPSW
driver are:
 - optimized promiscuous mode: The P0_UNI_FLOOD (both ports) is enabled in
addition to ALLMULTI (current port) instead of ALE_BYPASS.
So, Ports in promiscuous mode will keep possibility of mcast and vlan filtering,
which is provides significant benefits when ports are joined to the same bridge,
but without enabling "switch" mode, or to different bridges.
 - learning disabled on ports as it make not too much sense for
   segregated ports - no forwarding in HW.
 - enabled basic support for devlink.

	devlink dev show
		platform/48484000.switch

	devlink dev param show
	platform/48484000.switch:
	name switch_mode type driver-specific
	values:
		cmode runtime value false
	name ale_bypass type driver-specific
	values:
		cmode runtime value false

Devlink configuration parameters
====================
See Documentation/networking/devlink/ti-cpsw-switch.rst

====================
# Bridging in dual mac mode
====================
The dual_mac mode requires two vids to be reserved for internal purposes,
which, by default, equal CPSW Port numbers. As result, bridge has to be
configured in vlan unaware mode or default_pvid has to be adjusted.

	ip link add name br0 type bridge
	ip link set dev br0 type bridge vlan_filtering 0
	echo 0 > /sys/class/net/br0/bridge/default_pvid
	ip link set dev sw0p1 master br0
	ip link set dev sw0p2 master br0
 - or -
	ip link add name br0 type bridge
	ip link set dev br0 type bridge vlan_filtering 0
	echo 100 > /sys/class/net/br0/bridge/default_pvid
	ip link set dev br0 type bridge vlan_filtering 1
	ip link set dev sw0p1 master br0
	ip link set dev sw0p2 master br0

====================
# Enabling "switch"
====================
The Switch mode can be enabled by configuring devlink driver parameter
"switch_mode" to 1/true:
	devlink dev param set platform/48484000.switch \
	name switch_mode value 1 cmode runtime

This can be done regardless of the state of Port's netdev devices - UP/DOWN, but
Port's netdev devices have to be in UP before joining to the bridge to avoid
overwriting of bridge configuration as CPSW switch driver copletly reloads its
configuration when first Port changes its state to UP.

When the both interfaces joined the bridge - CPSW switch driver will enable
marking packets with offload_fwd_mark flag unless "ale_bypass=0"

All configuration is implemented via switchdev API.

====================
# Bridge setup
====================
	devlink dev param set platform/48484000.switch \
	name switch_mode value 1 cmode runtime

	ip link add name br0 type bridge
	ip link set dev br0 type bridge ageing_time 1000
	ip link set dev sw0p1 up
	ip link set dev sw0p2 up
	ip link set dev sw0p1 master br0
	ip link set dev sw0p2 master br0
	[*] bridge vlan add dev br0 vid 1 pvid untagged self

[*] if vlan_filtering=1. where default_pvid=1

=================
# On/off STP
=================
ip link set dev BRDEV type bridge stp_state 1/0

Note. Steps [*] are mandatory.

====================
# VLAN configuration
====================
bridge vlan add dev br0 vid 1 pvid untagged self <---- add cpu port to VLAN 1

Note. This step is mandatory for bridge/default_pvid.

=================
# Add extra VLANs
=================
 1. untagged:
    bridge vlan add dev sw0p1 vid 100 pvid untagged master
    bridge vlan add dev sw0p2 vid 100 pvid untagged master
    bridge vlan add dev br0 vid 100 pvid untagged self <---- Add cpu port to VLAN100

 2. tagged:
    bridge vlan add dev sw0p1 vid 100 master
    bridge vlan add dev sw0p2 vid 100 master
    bridge vlan add dev br0 vid 100 pvid tagged self <---- Add cpu port to VLAN100

====
FDBs
====
FDBs are automatically added on the appropriate switch port upon detection

Manually adding FDBs:
bridge fdb add aa:bb:cc:dd:ee:ff dev sw0p1 master vlan 100
bridge fdb add aa:bb:cc:dd:ee:fe dev sw0p2 master <---- Add on all VLANs

====
MDBs
====
MDBs are automatically added on the appropriate switch port upon detection

Manually adding MDBs:
bridge mdb add dev br0 port sw0p1 grp 239.1.1.1 permanent vid 100
bridge mdb add dev br0 port sw0p1 grp 239.1.1.1 permanent <---- Add on all VLANs

==================
Multicast flooding
==================
CPU port mcast_flooding is always on

Turning flooding on/off on swithch ports:
bridge link set dev sw0p1 mcast_flood on/off

==================
Access and Trunk port
==================
 bridge vlan add dev sw0p1 vid 100 pvid untagged master
 bridge vlan add dev sw0p2 vid 100 master


 bridge vlan add dev br0 vid 100 self
 ip link add link br0 name br0.100 type vlan id 100

 Note. Setting PVID on Bridge device itself working only for
 default VLAN (default_pvid).

=====================
 NFS
=====================
The only way for NFS to work is by chrooting to a minimal environment when
switch configuration that will affect connectivity is needed.
Assuming you are booting NFS with eth1 interface(the script is hacky and
it's just there to prove NFS is doable).

setup.sh:
#!/bin/sh
mkdir proc
mount -t proc none /proc
ifconfig br0  > /dev/null
if [ $? -ne 0 ]; then
        echo "Setting up bridge"
        ip link add name br0 type bridge
        ip link set dev br0 type bridge ageing_time 1000
        ip link set dev br0 type bridge vlan_filtering 1

        ip link set eth1 down
        ip link set eth1 name sw0p1
        ip link set dev sw0p1 up
        ip link set dev sw0p2 up
        ip link set dev sw0p2 master br0
        ip link set dev sw0p1 master br0
        bridge vlan add dev br0 vid 1 pvid untagged self
        ifconfig sw0p1 0.0.0.0
        udhchc -i br0
fi
umount /proc

run_nfs.sh:
#!/bin/sh
mkdir /tmp/root/bin -p
mkdir /tmp/root/lib -p

cp -r /lib/ /tmp/root/
cp -r /bin/ /tmp/root/
cp /sbin/ip /tmp/root/bin
cp /sbin/bridge /tmp/root/bin
cp /sbin/ifconfig /tmp/root/bin
cp /sbin/udhcpc /tmp/root/bin
cp /path/to/setup.sh /tmp/root/bin
chroot /tmp/root/ busybox sh /bin/setup.sh

run ./run_nfs.sh