What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/actual_cpi
Date:		January 2011
Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
Description:	The integer value of this attribute ranges from 1-4.
		When read, this attribute returns the number of the active
		cpi level.
		This file is readonly.
		Has never been used. If bookkeeping is done, it's done in userland tools.
Users:		http://roccat.sourceforge.net

What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/actual_sensitivity_x
Date:		January 2011
Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
Description:	The integer value of this attribute ranges from 1-10.
		When read, this attribute returns the number of the actual
		sensitivity in x direction.
		This file is readonly.
		Has never been used. If bookkeeping is done, it's done in userland tools.
Users:		http://roccat.sourceforge.net

What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/actual_sensitivity_y
Date:		January 2011
Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
Description:	The integer value of this attribute ranges from 1-10.
		When read, this attribute returns the number of the actual
		sensitivity in y direction.
		This file is readonly.
		Has never been used. If bookkeeping is done, it's done in userland tools.
Users:		http://roccat.sourceforge.net

What:		/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/firmware_version
Date:		January 2011
Contact:	Stefan Achatz <erazor_de@users.sourceforge.net>
Description:	When read, this file returns the raw integer version number of the
		firmware reported by the mouse. Using the integer value eases
		further usage in other programs. To receive the real version
		number the decimal point has to be shifted 2 positions to the
		left. E.g. a returned value of 121 means 1.21
		This file is readonly.
		Obsoleted by binary sysfs attribute "info".
Users:		http://roccat.sourceforge.net