Age | Commit message (Collapse) | Author | Files | Lines |
|
Add TIPC_NL_PEER_REMOVE netlink command. This command can remove
an offline peer node from the internal data structures.
This will be supported by the tipc user space tool in iproute2.
Signed-off-by: Richard Alpe <richard.alpe@ericsson.com>
Reviewed-by: Jon Maloy <jon.maloy@ericsson.com>
Acked-by: Ying Xue <ying.xue@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Global variables associated with node table are below:
- node table list (node_htable)
- node hash table list (tipc_node_list)
- node table lock (node_list_lock)
- node number counter (tipc_num_nodes)
- node link number counter (tipc_num_links)
To make node table support namespace, above global variables must be
moved to tipc_net structure in order to keep secret for different
namespaces. As a consequence, these variables are allocated and
initialized when namespace is created, and deallocated when namespace
is destroyed. After the change, functions associated with these
variables have to utilize a namespace pointer to access them. So
adding namespace pointer as a parameter of these functions is the
major change made in the commit.
Signed-off-by: Ying Xue <ying.xue@windriver.com>
Tested-by: Tero Aho <Tero.Aho@coriant.com>
Reviewed-by: Jon Maloy <jon.maloy@ericsson.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Involve namespace infrastructure, make the "tipc_net_id" global
variable aware of per namespace, and rename it to "net_id". In
order that the conversion can be successfully done, an instance
of networking namespace must be passed to relevant functions,
allowing them to access the "net_id" variable of per namespace.
Signed-off-by: Ying Xue <ying.xue@windriver.com>
Tested-by: Tero Aho <Tero.Aho@coriant.com>
Reviewed-by: Jon Maloy <jon.maloy@ericsson.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Add TIPC_NL_NET_SET command to the new tipc netlink API.
This command can set the network id and network (tipc) address.
Netlink logical layout of network set message:
-> net
[ -> id ]
[ -> address ]
Signed-off-by: Richard Alpe <richard.alpe@ericsson.com>
Reviewed-by: Erik Hugne <erik.hugne@ericsson.com>
Reviewed-by: Jon Maloy <jon.maloy@ericsson.com>
Acked-by: Ying Xue <ying.xue@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Add TIPC_NL_NET_GET command to the new tipc netlink API.
This command dumps the network id of the node.
Netlink logical layout of returned network data:
-> net
-> id
Signed-off-by: Richard Alpe <richard.alpe@ericsson.com>
Reviewed-by: Erik Hugne <erik.hugne@ericsson.com>
Reviewed-by: Jon Maloy <jon.maloy@ericsson.com>
Acked-by: Ying Xue <ying.xue@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
As a preparation to eliminate port_lock we need to bring reception
of connection protocol messages under proper protection of bh_lock_sock
or socket owner.
We fix this by letting those messages follow the same code path as
incoming data messages.
As a side effect of this change, the last reference to the function
net_route_msg() disappears, and we can eliminate that function.
Signed-off-by: Jon Maloy <jon.maloy@ericsson.com>
Reviewed-by: Erik Hugne <erik.hugne@ericsson.com>
Reviewed-by: Ying Xue <ying.xue@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Convert allocations of global variables associated with bclink from
static way to dynamical way for the convenience of bclink instance
initialisation. Meanwhile, this also helps TIPC support name space
in the future easily.
Signed-off-by: Ying Xue <ying.xue@windriver.com>
Reviewed-by: Erik Hugne <erik.hugne@ericsson.com>
Reviewed-by: Jon Maloy <jon.maloy@ericsson.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Now tipc routing hierarchy comprises the structures 'node', 'link'and
'bearer'. The whole hierarchy is protected by a big read/write lock,
tipc_net_lock, to ensure that nothing is added or removed while code
is accessing any of these structures. Obviously the locking policy
makes node, link and bearer components closely bound together so that
their relationship becomes unnecessarily complex. In the worst case,
such locking policy not only has a negative influence on performance,
but also it's prone to lead to deadlock occasionally.
In order o decouple the complex relationship between bearer and node
as well as link, the locking policy is adjusted as follows:
- Bearer level
RTNL lock is used on update side, and RCU is used on read side.
Meanwhile, all bearer instances including broadcast bearer are
saved into bearer_list array.
- Node and link level
All node instances are saved into two tipc_node_list and node_htable
lists. The two lists are protected by node_list_lock on write side,
and they are guarded with RCU lock on read side. All members in node
structure including link instances are protected by node spin lock.
- The relationship between bearer and node
When link accesses bearer, it first needs to find the bearer with
its bearer identity from the bearer_list array. When bearer accesses
node, it can iterate the node_htable hash list with the node
address to find the corresponding node.
In the new locking policy, every component has its private locking
solution and the relationship between bearer and node is very simple,
that is, they can find each other with node address or bearer identity
from node_htable hash list or bearer_list array.
Until now above all changes have been done, so tipc_net_lock can be
removed safely.
Signed-off-by: Ying Xue <ying.xue@windriver.com>
Reviewed-by: Jon Maloy <jon.maloy@ericsson.com>
Reviewed-by: Erik Hugne <erik.hugne@ericsson.com>
Tested-by: Erik Hugne <erik.hugne@ericsson.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Since now tipc_net_start() always returns a success code - 0, its
return value type should be changed from integer to void, which can
avoid unnecessary check for its return value.
Signed-off-by: Ying Xue <ying.xue@windriver.com>
Signed-off-by: Jon Maloy <jon.maloy@ericsson.com>
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Relocates network-related variables into the subsystem files where
they are now primarily used (following the recent rework of TIPC's
node table), and converts globals into locals where possible. Changes
the initialization of tipc_num_links from run-time to compile-time,
and eliminates the net_start routine that becomes empty as a result.
Also eliminates the corresponding net_stop routine by moving its
(trivial) content into the one location that called the routine.
Signed-off-by: Allan Stephens <allan.stephens@windriver.com>
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
|
|
Replaces the dynamically allocated array of pointers to the cluster's
node objects with a static hash table. Hash collisions are resolved
using chaining, with a typical hash chain having only a single node,
to avoid degrading performance during processing of incoming packets.
The conversion to a hash table reduces the memory requirements for
TIPC's node table to approximately the same size it had prior to
the previous commit.
In addition to the hash table itself, TIPC now also maintains a
linked list for the node objects, sorted by ascending network address.
This list allows TIPC to continue sending responses to user space
applications that request node and link information in sorted order.
The list also improves performance when name table update messages are
sent by making it easier to identify the nodes that must be notified.
Signed-off-by: Allan Stephens <allan.stephens@windriver.com>
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
|
|
Converts the fields of the global "tipc_net" structure into individual
variables. Since the struct was never referenced as a complete unit,
its existence was pointless. This will facilitate upcoming changes to
TIPC's node table and simpify upcoming relocation of the variables so
they are only visible to the files that actually use them.
This change is essentially cosmetic in nature, and doesn't affect the
operation of TIPC.
Signed-off-by: Allan Stephens <allan.stephens@windriver.com>
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
|
|
Removes a race condition that could cause TIPC's internal counter
of the number of links it has to neighboring nodes to have the
incorrect value if two independent threads of control simultaneously
create new link endpoints connecting to two different nodes using two
different bearers. Such under counting would result in TIPC failing to
list the final link(s) in its response to a configuration request to
list all of the node's links. The counter is now updated atomically
to ensure that simultaneous increments do not interfere with each
other.
Thanks go to Peter Butler <pbutler@pt.com> for his assistance in
diagnosing and fixing this problem.
Signed-off-by: Allan Stephens <Allan.Stephens@windriver.com>
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
|
|
Eliminates routines, data structures, and files that were intended
to allow TIPC to support a network containing multiple clusters.
Currently, TIPC supports only networks consisting of a single cluster
within a single zone, so this code is unnecessary.
Signed-off-by: Allan Stephens <Allan.Stephens@windriver.com>
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Eliminates routines and data structures that were intended to allow
TIPC to route messages to other clusters. Currently, TIPC supports only
networks consisting of a single cluster within a single zone, so this
code is unnecessary.
Signed-off-by: Allan Stephens <Allan.Stephens@windriver.com>
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Eliminates routines, data structures, and files that were intended
to allows TIPC to support a network containing multiple zones.
Currently, TIPC supports only networks consisting of a single cluster
within a single zone, so this code is unnecessary.
Signed-off-by: Allan Stephens <Allan.Stephens@windriver.com>
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Andrew Morton reported a build failure on sparc32, because TIPC
uses names like "struct node" and there is a like named data
structure defined in linux/node.h
This just regexp replaces "struct node*" to "struct tipc_node*"
to avoid this and any future similar problems.
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch ensures that TIPC's topology service and configuration
service are shut down before switching into "network mode". This
ensures that TIPC does not mistakenly try to send unnecessary
"publication withdraw" messages to other nodes before it is fully
initialized for sending off-node messages. Note that the node's
current network address is now updated only after the two services
are shut down; this ensures that any existing connections to the
topology server are terminated correctly using the old address.
Signed-off-by: Allan Stephens <allan.stephens@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Signed-off-by: YOSHIFUJI Hideaki <yoshfuji@linux-ipv6.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
This patch adds a tipc_ prefix to all externally visible symbols.
Signed-off-by: Per Liden <per.liden@ericsson.com>
|
|
Updated copyright notice to include the year the file was
actually created. Information about file creation dates
was extracted from the files in the old CVS repository
at tipc.sourceforge.net.
Signed-off-by: Per Liden <per.liden@nospam.ericsson.com>
|
|
The copyright statements from different parts of Ericsson
have been merged into one.
Signed-off-by: Per Liden <per.liden@nospam.ericsson.com>
|
|
The license header in each file now more clearly state that this
code is licensed under a dual BSD/GPL. Before this was only
evident if you looked at the MODULE_LICENSE line in core.c.
Signed-off-by: Per Liden <per.liden@nospam.ericsson.com>
|
|
TIPC (Transparent Inter Process Communication) is a protocol designed for
intra cluster communication. For more information see
http://tipc.sourceforge.net
Signed-off-by: Per Liden <per.liden@nospam.ericsson.com>
|