Age | Commit message (Collapse) | Author | Files | Lines | |
---|---|---|---|---|---|
2014-05-15 | Thermal/int3403: Fix thermal hysteresis unit conversion | lan,Tianyu | 1 | -1/+7 | |
Thermal hysteresis represents a temperature difference. But the original code treats it as a temperature value, Convert it from tenths of degree Kelvin to Milli-Celsius by deducing 273200. This is not right. Kelvin and Celsius have same degree size. From temperature difference view, the conversion between tenths of degree Kelvin unit and Milli-Celsius unit is just to multiply 100. Signed-off-by: Lan Tianyu <tianyu.lan@intel.com> Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com> | |||||
2014-01-02 | Thermal: ACPI INT3403 thermal driver | Srinivas Pandruvada | 1 | -0/+237 | |
The ACPI INT3403 device objects present on some systems can be used to retrieve temperature data from thermal sensors. Add a driver registering each INT3403 device object as a thermal zone device and exposing its _TMP, PATx and GTSH method via the standard thermal control interface under /sys/class/thermal/. Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com> |