summaryrefslogtreecommitdiffstats
path: root/drivers/nvme
AgeCommit message (Collapse)AuthorFilesLines
2019-09-25nvme: allow 64-bit results in passthru commandsMarta Rybczynska1-16/+92
It is not possible to get 64-bit results from the passthru commands, what prevents from getting for the Capabilities (CAP) property value. As a result, it is not possible to implement IOL's NVMe Conformance test 4.3 Case 1 for Fabrics targets [1] (page 123). This issue has been already discussed [2], but without a solution. This patch solves the problem by adding new ioctls with a new passthru structure, including 64-bit results. The older ioctls stay unchanged. [1] https://www.iol.unh.edu/sites/default/files/testsuites/nvme/UNH-IOL_NVMe_Conformance_Test_Suite_v11.0.pdf [2] http://lists.infradead.org/pipermail/linux-nvme/2018-June/018791.html Signed-off-by: Marta Rybczynska <marta.rybczynska@kalray.eu> Reviewed-by: Keith Busch <kbusch@kernel.org> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-25nvme: Add quirk for Kingston NVME SSD running FW E8FK11.TJian-Hong Pan1-0/+10
Kingston NVME SSD with firmware version E8FK11.T has no interrupt after resume with actions related to suspend to idle. This patch applied NVME_QUIRK_SIMPLE_SUSPEND quirk to fix this issue. Fixes: d916b1be94b6 ("nvme-pci: use host managed power state for suspend") Buglink: https://bugzilla.kernel.org/show_bug.cgi?id=204887 Signed-off-by: Jian-Hong Pan <jian-hong@endlessm.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-25nvmet-tcp: remove superflous check on request sglSagi Grimberg1-8/+4
Now that sgl_free is null safe, drop the superflous check. Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-25Added QUIRKs for ADATA XPG SX8200 Pro 512GBGabriel Craciunescu1-0/+3
Booting with default_ps_max_latency_us >6000 makes the device fail. Also SUBNQN is NULL and gives a warning on each boot/resume. $ nvme id-ctrl /dev/nvme0 | grep ^subnqn subnqn : (null) I use this device with an Acer Nitro 5 (AN515-43-R8BF) Laptop. To be sure is not a Laptop issue only, I tested the device on my server board with the same results. ( with 2x,4x link on the board and 4x link on a PCI-E card ). Signed-off-by: Gabriel Craciunescu <nix.or.die@gmail.com> Reviewed-by: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-25nvme-rdma: Fix max_hw_sectors calculationMax Gurtovoy1-5/+11
By default, the NVMe/RDMA driver should support max io_size of 1MiB (or upto the maximum supported size by the HCA). Currently, one will see that /sys/class/block/<bdev>/queue/max_hw_sectors_kb is 1020 instead of 1024. A non power of 2 value can cause performance degradation due to unnecessary splitting of IO requests and unoptimized allocation units. The number of pages per MR has been fixed here, so there is no longer any need to reduce max_sectors by 1. Reviewed-by: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Max Gurtovoy <maxg@mellanox.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-25nvme: fix an error code in nvme_init_subsystem()Dan Carpenter1-2/+3
"ret" should be a negative error code here, but it's either success or possibly uninitialized. Fixes: 32fd90c40768 ("nvme: change locking for the per-subsystem controller list") Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com> Reviewed-by: Keith Busch <kbusch@kernel.org> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-25nvme-pci: Save PCI state before putting drive into deepest stateMario Limonciello1-7/+10
The action of saving the PCI state will cause numerous PCI configuration space reads which depending upon the vendor implementation may cause the drive to exit the deepest NVMe state. In these cases ASPM will typically resolve the PCIe link state and APST may resolve the NVMe power state. However it has also been observed that this register access after quiesced will cause PC10 failure on some device combinations. To resolve this, move the PCI state saving to before SetFeatures has been called. This has been proven to resolve the issue across a 5000 sample test on previously failing disk/system combinations. Signed-off-by: Mario Limonciello <mario.limonciello@dell.com> Reviewed-by: Keith Busch <kbusch@kernel.org> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-25nvme-tcp: fix wrong stop condition in io_workWunderlich, Mark1-2/+2
Allow the do/while statement to continue if current time is not after the proposed time 'deadline'. Intent is to allow loop to proceed for a specific time period. Currently the loop, as coded, will exit after first pass. Signed-off-by: Mark Wunderlich <mark.wunderlich@intel.com> Reviewed-by: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-23nvme-pci: Fix a race in controller removalBalbir Singh1-1/+4
User space programs like udevd may try to read to partitions at the same time the driver detects a namespace is unusable, and may deadlock if revalidate_disk() is called while such a process is waiting to enter the frozen queue. On detecting a dead namespace, move the disk revalidate after unblocking dispatchers that may be holding bd_butex. changelog Suggested-by: Keith Busch <kbusch@kernel.org> Signed-off-by: Balbir Singh <sblbir@amzn.com> Reviewed-by: Keith Busch <kbusch@kernel.org> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-23nvmet: change ppl to lppJohn Pittman1-8/+8
In nvmet_bdev_set_limits() the number of logical blocks per physical block is calculated, but the opposite is mentioned in the associated comment and reflected in the variable name. Correct the comment and adjust the variable name to reflect the calculation done. Signed-off-by: John Pittman <jpittman@redhat.com> Reviewed-by: Bart Van Assche <bvanassche@acm.org> Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-17block: centralize PI remapping logic to the block layerMax Gurtovoy1-9/+0
Currently t10_pi_prepare/t10_pi_complete functions are called during the NVMe and SCSi layers command preparetion/completion, but their actual place should be the block layer since T10-PI is a general data integrity feature that is used by block storage protocols. Introduce .prepare_fn and .complete_fn callbacks within the integrity profile that each type can implement according to its needs. Suggested-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Christoph Hellwig <hch@lst.de> Suggested-by: Martin K. Petersen <martin.petersen@oracle.com> Reviewed-by: Martin K. Petersen <martin.petersen@oracle.com> Signed-off-by: Max Gurtovoy <maxg@mellanox.com> Fixed to not call queue integrity functions if BLK_DEV_INTEGRITY isn't defined in the config. Signed-off-by: Jens Axboe <axboe@kernel.dk>
2019-09-17Merge tag 'for-5.4/block-2019-09-16' of git://git.kernel.dk/linux-blockLinus Torvalds17-262/+566
Pull block updates from Jens Axboe: - Two NVMe pull requests: - ana log parse fix from Anton - nvme quirks support for Apple devices from Ben - fix missing bio completion tracing for multipath stack devices from Hannes and Mikhail - IP TOS settings for nvme rdma and tcp transports from Israel - rq_dma_dir cleanups from Israel - tracing for Get LBA Status command from Minwoo - Some nvme-tcp cleanups from Minwoo, Potnuri and Myself - Some consolidation between the fabrics transports for handling the CAP register - reset race with ns scanning fix for fabrics (move fabrics commands to a dedicated request queue with a different lifetime from the admin request queue)." - controller reset and namespace scan races fixes - nvme discovery log change uevent support - naming improvements from Keith - multiple discovery controllers reject fix from James - some regular cleanups from various people - Series fixing (and re-fixing) null_blk debug printing and nr_devices checks (André) - A few pull requests from Song, with fixes from Andy, Guoqing, Guilherme, Neil, Nigel, and Yufen. - REQ_OP_ZONE_RESET_ALL support (Chaitanya) - Bio merge handling unification (Christoph) - Pick default elevator correctly for devices with special needs (Damien) - Block stats fixes (Hou) - Timeout and support devices nbd fixes (Mike) - Series fixing races around elevator switching and device add/remove (Ming) - sed-opal cleanups (Revanth) - Per device weight support for BFQ (Fam) - Support for blk-iocost, a new model that can properly account cost of IO workloads. (Tejun) - blk-cgroup writeback fixes (Tejun) - paride queue init fixes (zhengbin) - blk_set_runtime_active() cleanup (Stanley) - Block segment mapping optimizations (Bart) - lightnvm fixes (Hans/Minwoo/YueHaibing) - Various little fixes and cleanups * tag 'for-5.4/block-2019-09-16' of git://git.kernel.dk/linux-block: (186 commits) null_blk: format pr_* logs with pr_fmt null_blk: match the type of parameter nr_devices null_blk: do not fail the module load with zero devices block: also check RQF_STATS in blk_mq_need_time_stamp() block: make rq sector size accessible for block stats bfq: Fix bfq linkage error raid5: use bio_end_sector in r5_next_bio raid5: remove STRIPE_OPS_REQ_PENDING md: add feature flag MD_FEATURE_RAID0_LAYOUT md/raid0: avoid RAID0 data corruption due to layout confusion. raid5: don't set STRIPE_HANDLE to stripe which is in batch list raid5: don't increment read_errors on EILSEQ return nvmet: fix a wrong error status returned in error log page nvme: send discovery log page change events to userspace nvme: add uevent variables for controller devices nvme: enable aen regardless of the presence of I/O queues nvme-fabrics: allow discovery subsystems accept a kato nvmet: Use PTR_ERR_OR_ZERO() in nvmet_init_discovery() nvme: Remove redundant assignment of cq vector nvme: Assign subsys instance from first ctrl ...
2019-09-12nvmet: fix a wrong error status returned in error log pageAmit1-5/+3
When the command data_len cannot hold all the controller errors, we should simply return as much errors as we can fit instead of failing the command. Signed-off-by: Amit Engel <amit.engel@dell.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: send discovery log page change events to userspaceSagi Grimberg1-1/+5
If the controller supports discovery log page change events, we want to enable it. When we see a discovery log change event we will send it up to userspace and expect it to handle it. Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com> Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: add uevent variables for controller devicesSagi Grimberg1-0/+28
When we send uevents to userspace, add controller specific environment variables to uniquly identify the controller beyond its device name. This will be useful to address discovery log change events by actually verifying that the discovery controller is indeed the same as the device that generated the event. Reviewed-by: Hannes Reinecke <hare@suse.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: enable aen regardless of the presence of I/O queuesSagi Grimberg1-2/+4
AENs in general are not related to the presence of I/O queues, so enable them regardless. Note that the only exception is that discovery controller will not support any of the requested AENs and nvme_enable_aen will respect that and return, so it is still safe to enable regardless. Note it is safe to enable AENs even before the initial namespace scanning as we have the scan operation in a workqueue context. Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com> Reviewed-by: Hannes Reinecke <hare@suse.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme-fabrics: allow discovery subsystems accept a katoSagi Grimberg1-10/+2
This modifies the behavior of discovery subsystems to accept a kato as a preparation to support discovery log change events. This also means that now every discovery controller will have a default kato value, and for non-persistent connections the host needs to pass in a zero kato value (keep_alive_tmo=0). Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com> Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvmet: Use PTR_ERR_OR_ZERO() in nvmet_init_discovery()Markus Elfring1-3/+1
Simplify this function implementation by using a known function. Generated by: scripts/coccinelle/api/ptr_ret.cocci Signed-off-by: Markus Elfring <elfring@users.sourceforge.net> Reviewed-by: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: Remove redundant assignment of cq vectorIsrael Rukshin1-1/+0
The cq vector is already assigned with the correct value. Signed-off-by: Israel Rukshin <israelr@mellanox.com> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Reviewed-by: Keith Busch <kbusch@kernel.org> Reviewed-off-by: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: Assign subsys instance from first ctrlKeith Busch1-11/+10
The namespace disk names must be unique for the lifetime of the subsystem. This was accomplished by using their parent subsystems' instances which were allocated independently from the controllers connected to that subsystem. This allowed name prefixes assigned to namespaces to match a controller from an unrelated subsystem, and has created confusion among users examining device nodes. Ensure a namespace's subsystem instance never clashes with a controller instance of another subsystem by transferring the instance ownership to the parent subsystem from the first controller discovered in that subsystem. Reviewed-by: Logan Gunthorpe <logang@deltatee.com> Signed-off-by: Keith Busch <kbusch@kernel.org> Reviewed-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Minwoo Im <minwoo.im@samsung.com> Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-off-by: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: tcp: remove redundant assignment to variable retColin Ian King1-1/+1
The variable ret is being initialized with a value that is never read and is being re-assigned immediately afterwards. The assignment is redundant and hence can be removed. Addresses-Coverity: ("Unused value") Signed-off-by: Colin Ian King <colin.king@canonical.com> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: include admin_q sync with nvme_sync_queuesEdmund Nadolski1-0/+3
nvme_sync_queues currently syncs all namespace queues, but should also sync the admin queue, if present. Signed-off-by: Edmund Nadolski <edmund.nadolski@intel.com> Reviewed-by: Keith Busch <kbusch@kernel.org> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: Treat discovery subsystems as unique subsystemsJames Smart1-0/+11
Current code matches subnqn and collapses all controllers to the same subnqn to a single subsystem structure. This is good for recognizing multiple controllers for the same subsystem. But with the well-known discovery subnqn, the subsystems aren't truly the same subsystem. As such, subsystem specific rules, such as no overlap of controller id, do not apply. With today's behavior, the check for overlap of controller id can fail, preventing the new discovery controller from being created. When searching for like subsystem nqn, exclude the discovery nqn from matching. This will result in each discovery controller being attached to a unique subsystem structure. Signed-off-by: James Smart <jsmart2021@gmail.com> Reviewed-by: Sagi Grimberg <sagi@grimberg.me> Reviewed-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: fix ns removal hang when failing to revalidate due to a transient errorSagi Grimberg1-1/+7
If a controller reset is racing with a namespace revalidation, the revalidation (admin) I/O will surely fail, but we should not remove the namespace as we will execute the I/O when the controller is back up. Same for spurious allocation errors (return -ENOMEM). Fix this by checking the specific error code in nvme_revalidate_disk and if it is a transient error (for example non DNR nvme statuses or a negative ENOMEM as allocation failure), do not remove the namespace as it will either recover when the controller is back up and schedule a subsequent scan, or the controller is going away and the namespaces will be removed anyways. This fixes a hang namespace scanning racing with a controller reset and also sporious I/O errors in path failover coditions where the controller reset is racing with the namespace scan work with multipath enabled. Reported-by: Hannes Reinecke <hare@suse.de> Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: make nvme_report_ns_ids propagate error backSagi Grimberg1-6/+22
Make the callers check the return status and propagate back accordingly (casting to errno from a positive nvme status). Also print the return status in nvme_report_ns_ids. Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: make nvme_identify_ns propagate errors backSagi Grimberg1-19/+20
right now callers of nvme_identify_ns only know that it failed, but don't know why. Make nvme_identify_ns propagate the error back. Because nvme_submit_sync_cmd may return a positive status code, we make nvme_identify_ns receive the id by reference and return that status up the call chain, but make sure not to leak positive nvme status codes to the upper layers. Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com> Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: pass status to nvme_error_statusSagi Grimberg1-3/+3
No need for the full blown request structure. Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme-fc: Fail transport errors with NVME_SC_HOST_PATHJames Smart1-7/+30
NVME_SC_INTERNAL should indicate an internal controller errors and not host transport errors. These errors will propagate to upper layers (essentially nvme core) and be interpereted as transport errors which should not be taken into account for namespace state or condition. Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme-tcp: fail command with NVME_SC_HOST_PATH_ERROR send failedSagi Grimberg1-1/+1
This is a more appropriate error status for a transport error detected by us (the host). Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12nvme: fail cancelled commands with NVME_SC_HOST_PATH_ERRORSagi Grimberg1-1/+3
NVME_SC_ABORT_REQ means that the request was aborted due to an abort command received. In our case, this is a transport cancellation, so host pathing error is much more appropriate. Also, convert NVME_SC_HOST_PATH_ERROR to BLK_STS_TRANSPORT for such that callers can understand that the status is a transport related error. This will be used by the ns scanning code to understand if it got an error from the controller or that the controller happens to be unreachable by the transport. Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com> Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-rdma: Use rq_dma_dir macroIsrael Rukshin1-7/+3
Remove code duplication. Signed-off-by: Israel Rukshin <israelr@mellanox.com> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-fc: Use rq_dma_dir macroIsrael Rukshin1-5/+2
Remove code duplication. Signed-off-by: Israel Rukshin <israelr@mellanox.com> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-pci: Tidy up nvme_unmap_dataIsrael Rukshin1-3/+2
Remove pointless local variable and use rq_dma_dir macro. Signed-off-by: Israel Rukshin <israelr@mellanox.com> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Reviewed-by: Keith Busch <kbusch@kernel.org> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme: make fabrics command run on a separate request queueSagi Grimberg6-14/+64
We have a fundamental issue that fabric commands use the admin_q. The reason is, that admin-connect, register reads and writes and admin commands cannot be guaranteed ordering while we are running controller resets. For example, when we reset a controller we perform: 1. disable the controller 2. teardown the admin queue 3. re-establish the admin queue 4. enable the controller In order to perform (3), we need to unquiesce the admin queue, however we may have some admin commands that are already pending on the quiesced admin_q and will immediate execute when we unquiesce it before we execute (4). The host must not send admin commands to the controller before enabling the controller. To fix this, we have the fabric commands (admin connect and property get/set, but not I/O queue connect) use a separate fabrics_q and make sure to quiesce the admin_q before we disable the controller, and unquiesce it only after we enable the controller. This fixes the error prints from nvmet in a controller reset storm test: kernel: nvmet: got cmd 6 while CC.EN == 0 on qid = 0 Which indicate that the host is sending an admin command when the controller is not enabled. Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-pci: Support shared tags across queues for Apple 2018 controllersBenjamin Herrenschmidt2-1/+35
Another issue with the Apple T2 based 2018 controllers seem to be that they blow up (and shut the machine down) if there's a tag collision between the IO queue and the Admin queue. My suspicion is that they use our tags for their internal tracking and don't mix them with the queue id. They also seem to not like when tags go beyond the IO queue depth, ie 128 tags. This adds a quirk that marks tags 0..31 of the IO queue reserved Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org> Reviewed-by: Ming Lei <ming.lei@redhat.com> Acked-by: Keith Busch <keith.busch@intel.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-pci: Add support for Apple 2018+ modelsBenjamin Herrenschmidt2-1/+30
Based on reverse engineering and original patch by Paul Pawlowski <paul@mrarm.io> This adds support for Apple weird implementation of NVME in their 2018 or later machines. It accounts for the twice-as-big SQ entries for the IO queues, and the fact that only interrupt vector 0 appears to function properly. Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org> Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-pci: Add support for variable IO SQ element sizeBenjamin Herrenschmidt1-3/+8
The size of a submission queue element should always be 6 (64 bytes) by spec. However some controllers such as Apple's are not properly implementing the standard and require a different size. This provides the ground work for the subsequent quirks for these controllers. Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org> Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-pci: Pass the queue to SQ_SIZE/CQ_SIZE macrosBenjamin Herrenschmidt1-15/+15
This will make it easier to handle variable queue entry sizes later. No functional change. Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org> Reviewed-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme: trace bio completionHannes Reinecke2-3/+21
When native multipathing is enabled we cannot enable blktrace for the underlying paths, so any completion is never traced. Signed-off-by: Hannes Reinecke <hare@suse.com> [fixed-up by Mikhail for non-multipath-build] Signed-off-by: Mikhail Skorzhinskii <mskorzhinskiy@solarflare.com> Reviewed-by: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-multipath: fix ana log nsid lookup when nsid is not foundAnton Eidelman1-3/+5
ANA log parsing invokes nvme_update_ana_state() per ANA group desc. This updates the state of namespaces with nsids in desc->nsids[]. Both ctrl->namespaces list and desc->nsids[] array are sorted by nsid. Hence nvme_update_ana_state() performs a single walk over ctrl->namespaces: - if current namespace matches the current desc->nsids[n], this namespace is updated, and n is incremented. - the process stops when it encounters the end of either ctrl->namespaces end or desc->nsids[] In case desc->nsids[n] does not match any of ctrl->namespaces, the remaining nsids following desc->nsids[n] will not be updated. Such situation was considered abnormal and generated WARN_ON_ONCE. However ANA log MAY contain nsids not (yet) found in ctrl->namespaces. For example, lets consider the following scenario: - nvme0 exposes namespaces with nsids = [2, 3] to the host - a new namespace nsid = 1 is added dynamically - also, a ANA topology change is triggered - NS_CHANGED aen is generated and triggers scan_work - before scan_work discovers nsid=1 and creates a namespace, a NOTICE_ANA aen was issues and ana_work receives ANA log with nsids=[1, 2, 3] Result: ana_work fails to update ANA state on existing namespaces [2, 3] Solution: Change the way nvme_update_ana_state() namespace list walk checks the current namespace against desc->nsids[n] as follows: a) ns->head->ns_id < desc->nsids[n]: keep walking ctrl->namespaces. b) ns->head->ns_id == desc->nsids[n]: match, update the namespace c) ns->head->ns_id >= desc->nsids[n]: skip to desc->nsids[n+1] This enables correct operation in the scenario described above. This also allows ANA log to contain nsids currently invisible to the host, i.e. inactive nsids. Signed-off-by: Anton Eidelman <anton@lightbitslabs.com> Reviewed-by: James Smart <james.smart@broadcom.com> Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvmet-tcp: Add TOS for tcp transportIsrael Rukshin1-0/+11
Set the outgoing packets type of service (TOS) according to the receiving TOS. Signed-off-by: Israel Rukshin <israelr@mellanox.com> Suggested-by: Sagi Grimberg <sagi@grimberg.me> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Reviewed-by: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-tcp: Add TOS for tcp transportIsrael Rukshin1-1/+14
TOS provide clients the ability to segregate traffic flows for different type of data. One of the TOS usage is bandwidth management which allows setting bandwidth limits for QoS classes, e.g. 80% bandwidth to controllers at QoS class A and 20% to controllers at QoS class B. usage examples: nvme connect --tos=0 --transport=tcp --traddr=10.0.1.1 --nqn=test-nvme Signed-off-by: Israel Rukshin <israelr@mellanox.com> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-tcp: Use struct nvme_ctrl directlyIsrael Rukshin1-10/+10
This patch doesn't change any functionality. Signed-off-by: Israel Rukshin <israelr@mellanox.com> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Reviewed-by: Sagi Grimberg <sagi@grimberg.me> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-rdma: Add TOS for rdma transportIsrael Rukshin1-3/+6
For RDMA transports, TOS is an extension of IB QoS to provide clients the ability to segregate traffic flows for different type of data. RDMA CM abstract it for ULPs using rdma_set_service_type(). Internally, each traffic flow is represented by a connection with all of its independent resources like that of a normal connection, and is differentiated by service type. In other words, there can be multiple qp connections between an IP pair and each supports a unique service type. One of the TOS usage is bandwidth management which allows setting bandwidth limits for QoS classes, e.g. 80% bandwidth to controllers at QoS class A and 20% to controllers at QoS class B. Note: In addition to the TOS configuration, QOS must be configured on the relevant HCA on the target (send RDMA commands) and initiator to effect the traffic. usage examples: nvme connect --tos=0 --transport=rdma --traddr=10.0.1.1 --nqn=test-nvme Signed-off-by: Israel Rukshin <israelr@mellanox.com> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme-fabrics: Add type of service (TOS) configurationIsrael Rukshin2-0/+21
TOS is user-defined and needs to be configured via nvme-cli. It must be set before initiating any traffic and once set the TOS cannot be changed. Signed-off-by: Israel Rukshin <israelr@mellanox.com> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvmet-tcp: fix possible memory leakSagi Grimberg1-0/+1
when we uninit a command in error flow we also need to free an iovec if it was allocated. Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvmet-tcp: fix possible NULL derefSagi Grimberg1-4/+8
We must only call sgl_free for sgl that we actually allocated. Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvmet: trace: parse Get LBA Status command in detailMinwoo Im1-0/+18
Four different fields are in CDWs of Get LBA Status command which means it would be great if we can see in detail when tracing in target side also. Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvme: trace: parse Get LBA Status command in detailMinwoo Im1-0/+18
Four different fields are in CDWs of Get LBA Status command which means it would be great if we can see in detail when tracing. Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29nvmet: fix data units read and written counters in SMART logTom Wu1-6/+8
In nvme spec 1.3 there is a definition for data write/read counters from SMART log, (See section 5.14.1.2): This value is reported in thousands (i.e., a value of 1 corresponds to 1000 units of 512 bytes read) and is rounded up. However, in nvme target where value is reported with actual units, but not thousands of units as the spec requires. Signed-off-by: Tom Wu <tomwu@mellanox.com> Reviewed-by: Israel Rukshin <israelr@mellanox.com> Reviewed-by: Max Gurtovoy <maxg@mellanox.com> Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Sagi Grimberg <sagi@grimberg.me>