summaryrefslogtreecommitdiffstats
path: root/drivers/iio/adc/ad7124.c
AgeCommit message (Collapse)AuthorFilesLines
2020-06-14iio: remove explicit IIO device parent assignmentAlexandru Ardelean1-1/+0
This patch applies the semantic patch: @@ expression I, P, SP; @@ I = devm_iio_device_alloc(P, SP); ... - I->dev.parent = P; It updates 302 files and does 307 deletions. This semantic patch also removes some comments like '/* Establish that the iio_dev is a child of the i2c device */' But this is is only done in case where the block is left empty. The patch does not seem to cover all cases. It looks like in some cases a different variable is used in some cases to assign the parent, but it points to the same reference. In other cases, the block covered by ... may be just too big to be covered by the semantic patch. However, this looks pretty good as well, as it does cover a big bulk of the drivers that should remove the parent assignment. Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-03-08iio: adc: ad7124: Add direct reg accessMircea Caprioru1-0/+30
This patch adds the posibility do read and write registers from userspace using the kernel debug direct register access option. Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-02-14iio: adc: ad7124: add 3db filterAlexandru Tachici1-1/+68
This patch adds the LOW_PASS_FILTER_3DB_FREQUENCY attribute in iio_chan_spec for each channel. The used filters are sinc3 or sinc4. The filter type with the highest output data rate is used when setting a low pass frequency in the channel's sysfs. Signed-off-by: Alexandru Tachici <alexandru.tachici@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-01-22Merge 5.5-rc7 into staging-nextGreg Kroah-Hartman1-7/+5
We want the staging fixes in here as well Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2020-01-18iio: adc: ad7124: Set IRQ type to fallingAlexandru Tachici1-1/+1
Ad7124 data-sheet specifies that the falling edge of the DOUT line should be used for an interrupt. The current irq flag (IRQF_TRIGGER_LOW) used will cause unwanted behaviour. When enabling the interrupt it will fire once because the DOUT line is already low. This will make the driver to read an unfinished conversion from the chip. This patch sets the irq type to the one specified in the data-sheet. Signed-off-by: Alexandru Tachici <alexandru.tachici@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-01-18iio: adc: ad-sigma-delta: Allow custom IRQ flagsAlexandru Tachici1-0/+2
Before this patch the ad_sigma_delta implementation hardcoded the irq trigger type to low, assuming that all Sigma-Delta ADCs have the same interrupt-type. This patch allows all drivers using the ad_sigma_delta layer to set the irq trigger type to the one specified in the datasheet. Signed-off-by: Alexandru Tachici <alexandru.tachici@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-01-13iio: adc: ad7124: Fix DT channel configurationAlexandru Tachici1-7/+5
This patch fixes device tree channel configuration. ad7124 driver reads channels configuration from the device tree. It expects to find channel specifications as child nodes. Before this patch ad7124 driver assumed that the child nodes are parsed by for_each_available_child_of_node in the order 0,1,2,3... This is wrong and the real order of the children can be seen by running: dtc -I fs /sys/firmware/devicetree/base on the machine. For example, running this on an rpi 3B+ yields the real children order: 4,2,0,7,5,3,1,6 Before this patch the driver assigned the channel configuration like this: - 0 <- 4 - 1 <- 2 - 2 <- 0 ........ For example, the symptoms can be observed by connecting the 4th channel to a 1V tension and then reading the in_voltage0-voltage19_raw sysfs (multiplied of course by the scale) one would see that channel 0 measures 1V and channel 4 measures only noise. Now the driver uses the reg property of each child in order to correctly identify to which channel the parsed configuration belongs to. Fixes b3af341bbd966: ("iio: adc: Add ad7124 support") Signed-off-by: Alexandru Tachici <alexandru.tachici@analog.com> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2019-12-08iio: adc: ad7124: Enable internal referenceMircea Caprioru1-1/+6
When the internal reference was selected by a channel it was not enabled. This patch fixes that and enables it. Fixes: b3af341bbd96 ("iio: adc: Add ad7124 support") Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-06-26iio: adc: ad7124: Shift to dynamic allocation for channel configurationMircea Caprioru1-1/+8
This patch changes the channel configuration member of the device structure from a fixed size array to a dynamic allocated one with a size equal to the number of channels specified in the device tree. This will ensure a more flexibility for compatible devices. Ex. ad7124-4 - can have 4 differential or 8 pseudo-differential channels ad7124-8 - can have 8 differential or 16 pseudo-differential channels Also the device can suspport any other combination of differential and pseudo-differential channels base on the physical number of inputs available. Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-06-26iio: adc: ad7124: Add buffered input supportMircea Caprioru1-2/+15
This patch adds the option to enable the buffered mode for positive and negative inputs. Each option can be enabled independently. In buffered mode, the input channel feeds into a high impedance input stage of the buffer amplifier. Therefore, the input can tolerate significant source impedances and is tailored for direct connection to external resistive type sensors such as strain gages or RTDs. Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-06-26iio: adc: ad7124: Remove input number limitationMircea Caprioru1-7/+0
The driver limits the user to use only 4/8 differential inputs, but this device has the option to use pseudo-differential channels. This will increase the number of channels to be equal with the number of inputs so 8 channels for ad7124-4 and 16 for ad7124-8. This patch removes the check between channel nodes and num_inputs value. Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-04-04iio: adc: ad7124 fix indentation issue, remove extra tabColin Ian King1-1/+1
A return statement is indented one level too deeply; clean this up by removing a tab. Signed-off-by: Colin Ian King <colin.king@canonical.com> Acked-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-11-17iio: adc: Add ad7124 supportStefan Popa1-0/+684
The ad7124-4 and ad7124-8 are a family of 4 and 8 channel sigma-delta ADCs with 24-bit precision and reference. Three power modes are available which in turn affect the output data rate: * Full power: 9.38 SPS to 19,200 SPS * Mid power: 2.34 SPS to 4800 SPS * Low power: 1.17 SPS to 2400 SPS The ad7124-4 can be configured to have four differential inputs, while ad7124-8 can have 8. Moreover, ad7124 also supports per channel configuration. Each configuration consists of gain, reference source, output data rate and bipolar/unipolar configuration. Datasheets: Link: http://www.analog.com/media/en/technical-documentation/data-sheets/AD7124-4.pdf Link: http://www.analog.com/media/en/technical-documentation/data-sheets/ad7124-8.pdf Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>