summaryrefslogtreecommitdiffstats
path: root/arch/powerpc/kernel/systbl.S
AgeCommit message (Collapse)AuthorFilesLines
2015-03-28powerpc: Add a proper syscall for switching endiannessMichael Ellerman1-0/+2
We currently have a "special" syscall for switching endianness. This is syscall number 0x1ebe, which is handled explicitly in the 64-bit syscall exception entry. That has a few problems, firstly the syscall number is outside of the usual range, which confuses various tools. For example strace doesn't recognise the syscall at all. Secondly it's handled explicitly as a special case in the syscall exception entry, which is complicated enough without it. As a first step toward removing the special syscall, we need to add a regular syscall that implements the same functionality. The logic is simple, it simply toggles the MSR_LE bit in the userspace MSR. This is the same as the special syscall, with the caveat that the special syscall clobbers fewer registers. This version clobbers r9-r12, XER, CTR, and CR0-1,5-7. Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
2014-07-28powerpc: Use standard macros for sys_sigpending() & sys_old_getrlimit()Michael Ellerman1-3/+0
Currently we have sys_sigpending and sys_old_getrlimit defined to use COMPAT_SYS() in systbl.h, but then both are #defined to sys_ni_syscall in systbl.S. This seems to have been done when ppc and ppc64 were merged, in commit 9994a33 "Introduce entry_{32,64}.S, misc_{32,64}.S, systbl.S". AFAICS there's no longer (or never was) any need for this, we can just use SYSX() for both and remove the #defines to sys_ni_syscall. The expansion before was: #define COMPAT_SYS(func) .llong .sys_##func,.compat_sys_##func #define sys_old_getrlimit sys_ni_syscall COMPAT_SYS(old_getrlimit) => .llong .sys_old_getrlimit,.compat_sys_old_getrlimit => .llong .sys_ni_syscall,.compat_sys_old_getrlimit After is: #define SYSX(f, f3264, f32) .llong .f,.f3264 SYSX(sys_ni_syscall, compat_sys_old_getrlimit, sys_old_getrlimit) => .llong .sys_ni_syscall,.compat_sys_old_getrlimit ie. they are equivalent. Finally both COMPAT_SYS() and SYSX() evaluate to sys_ni_syscall in the Cell SPU code. Signed-off-by: Michael Ellerman <mpe@ellerman.id.au> Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
2014-04-23powerpc: Create DOTSYM to wrap dot symbol usageAnton Blanchard1-6/+6
There are a few places we have to use dot symbols with the current ABI - the syscall table and the kvm hcall table. Wrap both of these with a new macro called DOTSYM so it will be easy to transition away from dot symbols in a future ABI. Signed-off-by: Anton Blanchard <anton@samba.org>
2014-04-23powerpc: Don't use a function descriptor for system call tableAnton Blanchard1-1/+5
There is no need to create a function descriptor for the system call table. By using one we force the system call table into the text section and it really belongs in the rodata section. This also removes another use of dot symbols. Signed-off-by: Anton Blanchard <anton@samba.org>
2007-10-11[POWERPC] Align the sys_call_tableStephen Rothwell1-0/+2
Our _GLOBAL macro does a ".align 2" so the alignment is fine for 32 bit, but on 64 bit it is possible for it to end up only 4 byte aligned. I don't know if it matters, but it can't hurt to 8 byte align it. It also means that when we build with --emit_relocs, none of our 64 bit relocations are to misaligned places. Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au> Signed-off-by: Paul Mackerras <paulus@samba.org>
2006-06-30Remove obsolete #include <linux/config.h>Jörn Engel1-1/+0
Signed-off-by: Jörn Engel <joern@wohnheim.fh-wedel.de> Signed-off-by: Adrian Bunk <bunk@stusta.de>
2006-06-21[POWERPC] Unify ppc syscall tablesAndreas Schwab1-306/+5
Avoid duplication of the syscall table for the cell platform. Based on an idea from David Woodhouse. Signed-off-by: Andreas Schwab <schwab@suse.de> Acked-by: Arnd Bergmann <arnd.bergmann@de.ibm.com> Signed-off-by: Paul Mackerras <paulus@samba.org>
2006-05-23[PATCH] powerpc: wire up sys_[gs]et_robust_listDavid Woodhouse1-0/+2
Signed-off-by: David Woodhouse <dwmw2@infradead.org> Cc: Benjamin Herrenschmidt <benh@kernel.crashing.org> Acked-by: Paul Mackerras <paulus@samba.org> Cc: Arnd Bergmann <arnd@arndb.de> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2006-04-28[PATCH] powerpc: Wire up *at syscallsAndreas Schwab1-0/+13
Wire up *at syscalls. This patch has been tested on ppc64 (using glibc's testsuite, both 32bit and 64bit), and compile-tested for ppc32 (I have currently no ppc32 system available, but I expect no problems). Signed-off-by: Andreas Schwab <schwab@suse.de> Signed-off-by: Paul Mackerras <paulus@samba.org>
2006-04-26[PATCH] Add support for the sys_vmsplice syscallJens Axboe1-0/+1
sys_splice() moves data to/from pipes with a file input/output. sys_vmsplice() moves data to a pipe, with the input being a user address range instead. This uses an approach suggested by Linus, where we can hold partial ranges inside the pages[] map. Hopefully this will be useful for network receive support as well. Signed-off-by: Jens Axboe <axboe@suse.de>
2006-04-21[PATCH] powerpc/cell: remove BUILD_BUG_ON and add sys_tee to spu_syscall_tableArnd Bergmann1-0/+5
Every time a new syscall gets added, a BUILD_BUG_ON in arch/powerpc/platforms/cell/spu_callbacks.c gets triggered. Since the addition of a new syscall is rather harmless, the error should just be removed. While we're here, add sys_tee to the list and add a comment to systbl.S to remind people that there is another list on powerpc. Signed-off-by: Arnd Bergmann <arnd.bergmann@de.ibm.com> Signed-off-by: Paul Mackerras <paulus@samba.org>
2006-04-11[PATCH] splice: add support for sys_tee()Jens Axboe1-0/+1
Basically an in-kernel implementation of tee, which uses splice and the pipe buffers as an intelligent way to pass data around by reference. Where the user space tee consumes the input and produces a stdout and file output, this syscall merely duplicates the data inside a pipe to another pipe. No data is copied, the output just grabs a reference to the input pipe data. Signed-off-by: Jens Axboe <axboe@suse.de>
2006-04-02ppc64: actually add sys_splice() to the system call tableLinus Torvalds1-0/+1
(We'd only added the number, which meant that actually trying to use splice just went off into la-la-land) Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2006-03-08powerpc: Fix various syscall/signal/swapcontext bugsPaul Mackerras1-1/+1
A careful reading of the recent changes to the system call entry/exit paths revealed several problems, plus some things that could be simplified and improved: * 32-bit wasn't testing the _TIF_NOERROR bit in the syscall fast exit path, so it was only doing anything with it once it saw some other bit being set. In other words, the noerror behaviour would apply to the next system call where we had to reschedule or deliver a signal, which is not necessarily the current system call. * 32-bit wasn't doing the call to ptrace_notify in the syscall exit path when the _TIF_SINGLESTEP bit was set. * _TIF_RESTOREALL was in both _TIF_USER_WORK_MASK and _TIF_PERSYSCALL_MASK, which is odd since _TIF_RESTOREALL is only set by system calls. I took it out of _TIF_USER_WORK_MASK. * On 64-bit, _TIF_RESTOREALL wasn't causing the non-volatile registers to be restored (unless perhaps a signal was delivered or the syscall was traced or single-stepped). Thus the non-volatile registers weren't restored on exit from a signal handler. We probably got away with it mostly because signal handlers written in C wouldn't alter the non-volatile registers. * On 32-bit I simplified the code and made it more like 64-bit by making the syscall exit path jump to ret_from_except to handle preemption and signal delivery. * 32-bit was calling do_signal unnecessarily when _TIF_RESTOREALL was set - but I think because of that 32-bit was actually restoring the non-volatile registers on exit from a signal handler. * I changed the order of enabling interrupts and saving the non-volatile registers before calling do_syscall_trace_leave; now we enable interrupts first. Signed-off-by: Paul Mackerras <paulus@samba.org>
2006-02-10[PATCH] powerpc: unshare system call registrationJANAK DESAI1-0/+1
Registers system call for the powerpc architecture. Signed-off-by: Janak Desai <janak@us.ibm.com> Cc: Al Viro <viro@ftp.linux.org.uk> Cc: Christoph Hellwig <hch@lst.de> Cc: Michael Kerrisk <mtk-manpages@gmx.net> Cc: Benjamin Herrenschmidt <benh@kernel.crashing.org> Cc: Andi Kleen <ak@muc.de> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Paul Mackerras <paulus@samba.org>
2006-02-10ppc: Use the system call table from arch/powerpc/kernel/systbl.SPaul Mackerras1-2/+0
With this, new system calls only have to be wired up in one place for ARCH=ppc and ARCH=powerpc, rather than 2. Signed-off-by: Paul Mackerras <paulus@samba.org>
2006-01-18[PATCH] TIF_RESTORE_SIGMASK support for arch/powerpcDavid Woodhouse1-0/+2
Implement the TIF_RESTORE_SIGMASK flag in the new arch/powerpc kernel, for both 32-bit and 64-bit system call paths. Signed-off-by: David Woodhouse <dwmw2@infradead.org> Cc: Benjamin Herrenschmidt <benh@kernel.crashing.org> Cc: Paul Mackerras <paulus@samba.org> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2006-01-10Merge git://git.kernel.org/pub/scm/linux/kernel/git/paulus/powerpc-mergeLinus Torvalds1-3/+3
2006-01-10[PATCH] common compat_sys_timer_createChristoph Hellwig1-1/+1
The comment in compat.c is wrong, every architecture provides a get_compat_sigevent() for the IPC compat code already. This basically moves the x86_64 version to common code and removes all the others. Signed-off-by: Christoph Hellwig <hch@lst.de> Acked-by: Paul Mackerras <paulus@samba.org> Cc: Arnd Bergmann <arnd@arndb.de> Cc: Benjamin Herrenschmidt <benh@kernel.crashing.org> Cc: Martin Schwidefsky <schwidefsky@de.ibm.com> Cc: "David S. Miller" <davem@davemloft.net> Acked-by: Andi Kleen <ak@muc.de> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2006-01-10[PATCH] powerpc: remove compat_sys_pciconfig_*Stephen Rothwell1-3/+3
Matthew Wilcox wondered why we need these functions. We don't. Remove them and just use the "normal" versions. Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au> Signed-off-by: Paul Mackerras <paulus@samba.org>
2006-01-09[PATCH] ppc64: fix time syscallAnton Blanchard1-1/+1
ppc64 has its own version of sys_time. It looks pretty scary, touching a whole bunch of variables without any locking or memory ordering. In fact, a recent bugreport has shown it can actually go backwards. Time to remove it and just use the generic sys_time, which is implemented on top of do_gettimeofday. Signed-off-by: Anton Blanchard <anton@samba.org> Signed-off-by: Paul Mackerras <paulus@samba.org>
2006-01-09[PATCH] spufs: The SPU file system, baseArnd Bergmann1-0/+2
This is the current version of the spu file system, used for driving SPEs on the Cell Broadband Engine. This release is almost identical to the version for the 2.6.14 kernel posted earlier, which is available as part of the Cell BE Linux distribution from http://www.bsc.es/projects/deepcomputing/linuxoncell/. The first patch provides all the interfaces for running spu application, but does not have any support for debugging SPU tasks or for scheduling. Both these functionalities are added in the subsequent patches. See Documentation/filesystems/spufs.txt on how to use spufs. Signed-off-by: Arnd Bergmann <arndb@de.ibm.com> Signed-off-by: Paul Mackerras <paulus@samba.org>
2006-01-09[PATCH] syscall entry/exit revampDavid Woodhouse1-5/+5
This cleanup patch speeds up the null syscall path on ppc64 by about 3%, and brings the ppc32 and ppc64 code slightly closer together. The ppc64 code was checking current_thread_info()->flags twice in the syscall exit path; once for TIF_SYSCALL_T_OR_A before disabling interrupts, and then again for TIF_SIGPENDING|TIF_NEED_RESCHED etc after disabling interrupts. Now we do the same as ppc32 -- check the flags only once in the fast path, and re-enable interrupts if necessary in the ptrace case. The patch abolishes the 'syscall_noerror' member of struct thread_info and replaces it with a TIF_NOERROR bit in the flags, which is handled in the slow path. This shortens the syscall entry code, which no longer needs to clear syscall_noerror. The patch adds a TIF_SAVE_NVGPRS flag which causes the syscall exit slow path to save the non-volatile GPRs into a signal frame. This removes the need for the assembly wrappers around sys_sigsuspend(), sys_rt_sigsuspend(), et al which existed solely to save those registers in advance. It also means I don't have to add new wrappers for ppoll() and pselect(), which is what I was supposed to be doing when I got distracted into this... Finally, it unifies the ppc64 and ppc32 methods of handling syscall exit directly into a signal handler (as required by sigsuspend et al) by introducing a TIF_RESTOREALL flag which causes _all_ the registers to be reloaded from the pt_regs by taking the ret_from_exception path, instead of the normal syscall exit path which stomps on the callee-saved GPRs. It appears to pass an LTP test run on ppc64, and passes basic testing on ppc32 too. Brief tests of ptrace functionality with strace and gdb also appear OK. I wouldn't send it to Linus for 2.6.15 just yet though :) Signed-off-by: David Woodhouse <dwmw2@infradead.org> Signed-off-by: Paul Mackerras <paulus@samba.org>
2005-10-18Merge rsync://oak/kernels/iseries/work/Paul Mackerras1-59/+57
2005-10-18powerpc: change sys32_ to compat_sys_Stephen Rothwell1-59/+57
This allows us to get rid of one type of entry in systbl.S. In passing we remove the duplicate compat_sys_getdents and compat_sys_utimes for which there are generic versions. Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
2005-10-18powerpc: Fix various compile errors with ARCH=ppc, ppc64 and powerpcPaul Mackerras1-1/+1
This makes ppc use the syscalls.c from arch/powerpc/kernel, exports copy_and_flush from head_32.S for use by prom_init.c (ARCH=powerpc), and consolidates the sys_fadvise64_64 implementations for 32-bit. Signed-off-by: Paul Mackerras <paulus@samba.org>
2005-10-17powerpc: Merge syscalls.c and sys_ppc32.c.Paul Mackerras1-3/+3
Signed-off-by: Paul Mackerras <paulus@samba.org>
2005-10-10powerpc: Introduce entry_{32,64}.S, misc_{32,64}.S, systbl.SPaul Mackerras1-0/+323
The system call table has been consolidated into systbl.S. We have separate 32-bit and 64-bit versions of entry.S and misc.S since the code is mostly sufficiently different to be not worth merging. There are some common bits that will be extracted in future. Signed-off-by: Paul Mackerras <paulus@samba.org>