diff options
Diffstat (limited to 'include')
-rw-r--r-- | include/linux/mfd/abx500.h | 6 | ||||
-rw-r--r-- | include/linux/mfd/abx500/ab8500-bm.h | 2 |
2 files changed, 6 insertions, 2 deletions
diff --git a/include/linux/mfd/abx500.h b/include/linux/mfd/abx500.h index 4906b1842d2f..0e6e90badfca 100644 --- a/include/linux/mfd/abx500.h +++ b/include/linux/mfd/abx500.h @@ -131,7 +131,7 @@ struct abx500_maxim_parameters { * @nominal_voltage: Nominal voltage of the battery in mV * @termination_vol: max voltage upto which battery can be charged * @termination_curr battery charging termination current in mA - * @recharge_vol battery voltage limit that will trigger a new + * @recharge_cap battery capacity limit that will trigger a new * full charging cycle in the case where maintenan- * -ce charging has been disabled * @normal_cur_lvl: charger current in normal state in mA @@ -160,7 +160,7 @@ struct abx500_battery_type { int nominal_voltage; int termination_vol; int termination_curr; - int recharge_vol; + int recharge_cap; int normal_cur_lvl; int normal_vol_lvl; int maint_a_cur_lvl; @@ -224,6 +224,7 @@ struct abx500_bm_charger_parameters { * @bkup_bat_v voltage which we charge the backup battery with * @bkup_bat_i current which we charge the backup battery with * @no_maintenance indicates that maintenance charging is disabled + * @capacity_scaling indicates whether capacity scaling is to be used * @abx500_adc_therm placement of thermistor, batctrl or battemp adc * @chg_unknown_bat flag to enable charging of unknown batteries * @enable_overshoot flag to enable VBAT overshoot control @@ -254,6 +255,7 @@ struct abx500_bm_data { int bkup_bat_v; int bkup_bat_i; bool no_maintenance; + bool capacity_scaling; bool chg_unknown_bat; bool enable_overshoot; bool auto_trig; diff --git a/include/linux/mfd/abx500/ab8500-bm.h b/include/linux/mfd/abx500/ab8500-bm.h index 6c6a02e53cd9..fac684a6f346 100644 --- a/include/linux/mfd/abx500/ab8500-bm.h +++ b/include/linux/mfd/abx500/ab8500-bm.h @@ -355,6 +355,7 @@ struct ab8500_bm_charger_parameters { * @bkup_bat_v voltage which we charge the backup battery with * @bkup_bat_i current which we charge the backup battery with * @no_maintenance indicates that maintenance charging is disabled + * @capacity_scaling indicates whether capacity scaling is to be used * @adc_therm placement of thermistor, batctrl or battemp adc * @chg_unknown_bat flag to enable charging of unknown batteries * @enable_overshoot flag to enable VBAT overshoot control @@ -383,6 +384,7 @@ struct ab8500_bm_data { int bkup_bat_v; int bkup_bat_i; bool no_maintenance; + bool capacity_scaling; bool chg_unknown_bat; bool enable_overshoot; enum abx500_adc_therm adc_therm; |