diff options
Diffstat (limited to 'fs')
-rw-r--r-- | fs/cifs/inode.c | 324 |
1 files changed, 178 insertions, 146 deletions
diff --git a/fs/cifs/inode.c b/fs/cifs/inode.c index 422d4e219fa4..1cf43e101943 100644 --- a/fs/cifs/inode.c +++ b/fs/cifs/inode.c @@ -161,6 +161,12 @@ static void cifs_unix_info_to_inode(struct inode *inode, spin_unlock(&inode->i_lock); } + +/* + * Needed to setup inode data for the directory which is the + * junction to the new submount (ie to setup the fake directory + * which represents a DFS referral) + */ static void fill_fake_finddataunix(FILE_UNIX_BASIC_INFO *pfnd_dat, struct super_block *sb) { @@ -370,11 +376,42 @@ static int get_sfu_mode(struct inode *inode, #endif } +/* + * Needed to setup inode data for the directory which is the + * junction to the new submount (ie to setup the fake directory + * which represents a DFS referral) + */ +static void fill_fake_finddata(FILE_ALL_INFO *pfnd_dat, + struct super_block *sb) +{ + memset(pfnd_dat, sizeof(FILE_ALL_INFO), 0); + +/* __le64 pfnd_dat->AllocationSize = cpu_to_le64(0); + __le64 pfnd_dat->EndOfFile = cpu_to_le64(0); + __u8 pfnd_dat->DeletePending = 0; + __u8 pfnd_data->Directory = 0; + __le32 pfnd_dat->EASize = 0; + __u64 pfnd_dat->IndexNumber = 0; + __u64 pfnd_dat->IndexNumber1 = 0; */ + pfnd_dat->CreationTime = + cpu_to_le64(cifs_UnixTimeToNT(CURRENT_TIME)); + pfnd_dat->LastAccessTime = + cpu_to_le64(cifs_UnixTimeToNT(CURRENT_TIME)); + pfnd_dat->LastWriteTime = + cpu_to_le64(cifs_UnixTimeToNT(CURRENT_TIME)); + pfnd_dat->ChangeTime = + cpu_to_le64(cifs_UnixTimeToNT(CURRENT_TIME)); + pfnd_dat->Attributes = cpu_to_le32(ATTR_DIRECTORY); + pfnd_dat->NumberOfLinks = cpu_to_le32(2); +} + int cifs_get_inode_info(struct inode **pinode, const unsigned char *full_path, FILE_ALL_INFO *pfindData, struct super_block *sb, int xid, const __u16 *pfid) { int rc = 0; + __u32 attr; + struct cifsInodeInfo *cifsInfo; struct cifsTconInfo *pTcon; struct inode *inode; struct cifs_sb_info *cifs_sb = CIFS_SB(sb); @@ -399,7 +436,6 @@ int cifs_get_inode_info(struct inode **pinode, return -ENOMEM; pfindData = (FILE_ALL_INFO *)buf; -try_again_CIFSSMBQPathInfo: /* could do find first instead but this returns more info */ rc = CIFSSMBQPathInfo(xid, pTcon, full_path, pfindData, 0 /* not legacy */, @@ -417,171 +453,167 @@ try_again_CIFSSMBQPathInfo: } } /* dump_mem("\nQPathInfo return data",&findData, sizeof(findData)); */ - if (rc) { - if (rc == -EREMOTE && !is_dfs_referral) { - is_dfs_referral = true; - goto try_again_CIFSSMBQPathInfo; - } + if (rc == -EREMOTE) { + is_dfs_referral = true; + fill_fake_finddata(pfindData, sb); + rc = 0; + } else if (rc) goto cgii_exit; - } else { - struct cifsInodeInfo *cifsInfo; - __u32 attr = le32_to_cpu(pfindData->Attributes); - /* get new inode */ + attr = le32_to_cpu(pfindData->Attributes); + + /* get new inode */ + if (*pinode == NULL) { + *pinode = new_inode(sb); if (*pinode == NULL) { - *pinode = new_inode(sb); - if (*pinode == NULL) { - rc = -ENOMEM; - goto cgii_exit; - } - /* Is an i_ino of zero legal? Can we use that to check - if the server supports returning inode numbers? Are - there other sanity checks we can use to ensure that - the server is really filling in that field? */ + rc = -ENOMEM; + goto cgii_exit; + } + /* Is an i_ino of zero legal? Can we use that to check + if the server supports returning inode numbers? Are + there other sanity checks we can use to ensure that + the server is really filling in that field? */ - /* We can not use the IndexNumber field by default from - Windows or Samba (in ALL_INFO buf) but we can request - it explicitly. It may not be unique presumably if - the server has multiple devices mounted under one - share */ + /* We can not use the IndexNumber field by default from + Windows or Samba (in ALL_INFO buf) but we can request + it explicitly. It may not be unique presumably if + the server has multiple devices mounted under one share */ - /* There may be higher info levels that work but are - there Windows server or network appliances for which - IndexNumber field is not guaranteed unique? */ + /* There may be higher info levels that work but are + there Windows server or network appliances for which + IndexNumber field is not guaranteed unique? */ - if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM) { - int rc1 = 0; - __u64 inode_num; + if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM) { + int rc1 = 0; + __u64 inode_num; - rc1 = CIFSGetSrvInodeNumber(xid, pTcon, + rc1 = CIFSGetSrvInodeNumber(xid, pTcon, full_path, &inode_num, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); - if (rc1) { - cFYI(1, ("GetSrvInodeNum rc %d", rc1)); - /* BB EOPNOSUPP disable SERVER_INUM? */ - } else /* do we need cast or hash to ino? */ - (*pinode)->i_ino = inode_num; - } /* else ino incremented to unique num in new_inode*/ - if (sb->s_flags & MS_NOATIME) - (*pinode)->i_flags |= S_NOATIME | S_NOCMTIME; - insert_inode_hash(*pinode); - } - inode = *pinode; - cifsInfo = CIFS_I(inode); - cifsInfo->cifsAttrs = attr; - cFYI(1, ("Old time %ld", cifsInfo->time)); - cifsInfo->time = jiffies; - cFYI(1, ("New time %ld", cifsInfo->time)); - - /* blksize needs to be multiple of two. So safer to default to - blksize and blkbits set in superblock so 2**blkbits and blksize - will match rather than setting to: - (pTcon->ses->server->maxBuf - MAX_CIFS_HDR_SIZE) & 0xFFFFFE00;*/ - - /* Linux can not store file creation time so ignore it */ - if (pfindData->LastAccessTime) - inode->i_atime = cifs_NTtimeToUnix - (le64_to_cpu(pfindData->LastAccessTime)); - else /* do not need to use current_fs_time - time not stored */ - inode->i_atime = CURRENT_TIME; - inode->i_mtime = + if (rc1) { + cFYI(1, ("GetSrvInodeNum rc %d", rc1)); + /* BB EOPNOSUPP disable SERVER_INUM? */ + } else /* do we need cast or hash to ino? */ + (*pinode)->i_ino = inode_num; + } /* else ino incremented to unique num in new_inode*/ + if (sb->s_flags & MS_NOATIME) + (*pinode)->i_flags |= S_NOATIME | S_NOCMTIME; + insert_inode_hash(*pinode); + } + inode = *pinode; + cifsInfo = CIFS_I(inode); + cifsInfo->cifsAttrs = attr; + cFYI(1, ("Old time %ld", cifsInfo->time)); + cifsInfo->time = jiffies; + cFYI(1, ("New time %ld", cifsInfo->time)); + + /* blksize needs to be multiple of two. So safer to default to + blksize and blkbits set in superblock so 2**blkbits and blksize + will match rather than setting to: + (pTcon->ses->server->maxBuf - MAX_CIFS_HDR_SIZE) & 0xFFFFFE00;*/ + + /* Linux can not store file creation time so ignore it */ + if (pfindData->LastAccessTime) + inode->i_atime = cifs_NTtimeToUnix + (le64_to_cpu(pfindData->LastAccessTime)); + else /* do not need to use current_fs_time - time not stored */ + inode->i_atime = CURRENT_TIME; + inode->i_mtime = cifs_NTtimeToUnix(le64_to_cpu(pfindData->LastWriteTime)); - inode->i_ctime = - cifs_NTtimeToUnix(le64_to_cpu(pfindData->ChangeTime)); - cFYI(0, ("Attributes came in as 0x%x", attr)); - if (adjustTZ && (pTcon->ses) && (pTcon->ses->server)) { - inode->i_ctime.tv_sec += pTcon->ses->server->timeAdj; - inode->i_mtime.tv_sec += pTcon->ses->server->timeAdj; - } + inode->i_ctime = + cifs_NTtimeToUnix(le64_to_cpu(pfindData->ChangeTime)); + cFYI(DBG2, ("Attributes came in as 0x%x", attr)); + if (adjustTZ && (pTcon->ses) && (pTcon->ses->server)) { + inode->i_ctime.tv_sec += pTcon->ses->server->timeAdj; + inode->i_mtime.tv_sec += pTcon->ses->server->timeAdj; + } - /* set default mode. will override for dirs below */ - if (atomic_read(&cifsInfo->inUse) == 0) - /* new inode, can safely set these fields */ - inode->i_mode = cifs_sb->mnt_file_mode; - else /* since we set the inode type below we need to mask off - to avoid strange results if type changes and both - get orred in */ - inode->i_mode &= ~S_IFMT; -/* if (attr & ATTR_REPARSE) */ - /* We no longer handle these as symlinks because we could not - follow them due to the absolute path with drive letter */ - if (attr & ATTR_DIRECTORY) { - /* override default perms since we do not do byte range locking - on dirs */ - inode->i_mode = cifs_sb->mnt_dir_mode; - inode->i_mode |= S_IFDIR; - } else if ((cifs_sb->mnt_cifs_flags & CIFS_MOUNT_UNX_EMUL) && - (cifsInfo->cifsAttrs & ATTR_SYSTEM) && - /* No need to le64 convert size of zero */ - (pfindData->EndOfFile == 0)) { - inode->i_mode = cifs_sb->mnt_file_mode; - inode->i_mode |= S_IFIFO; + /* set default mode. will override for dirs below */ + if (atomic_read(&cifsInfo->inUse) == 0) + /* new inode, can safely set these fields */ + inode->i_mode = cifs_sb->mnt_file_mode; + else /* since we set the inode type below we need to mask off + to avoid strange results if type changes and both + get orred in */ + inode->i_mode &= ~S_IFMT; +/* if (attr & ATTR_REPARSE) */ + /* We no longer handle these as symlinks because we could not + follow them due to the absolute path with drive letter */ + if (attr & ATTR_DIRECTORY) { + /* override default perms since we do not do byte range locking + on dirs */ + inode->i_mode = cifs_sb->mnt_dir_mode; + inode->i_mode |= S_IFDIR; + } else if ((cifs_sb->mnt_cifs_flags & CIFS_MOUNT_UNX_EMUL) && + (cifsInfo->cifsAttrs & ATTR_SYSTEM) && + /* No need to le64 convert size of zero */ + (pfindData->EndOfFile == 0)) { + inode->i_mode = cifs_sb->mnt_file_mode; + inode->i_mode |= S_IFIFO; /* BB Finish for SFU style symlinks and devices */ - } else if ((cifs_sb->mnt_cifs_flags & CIFS_MOUNT_UNX_EMUL) && - (cifsInfo->cifsAttrs & ATTR_SYSTEM)) { - if (decode_sfu_inode(inode, - le64_to_cpu(pfindData->EndOfFile), - full_path, - cifs_sb, xid)) - cFYI(1, ("Unrecognized sfu inode type")); - - cFYI(1, ("sfu mode 0%o", inode->i_mode)); - } else { - inode->i_mode |= S_IFREG; - /* treat the dos attribute of read-only as read-only - mode e.g. 555 */ - if (cifsInfo->cifsAttrs & ATTR_READONLY) - inode->i_mode &= ~(S_IWUGO); - else if ((inode->i_mode & S_IWUGO) == 0) - /* the ATTR_READONLY flag may have been */ - /* changed on server -- set any w bits */ - /* allowed by mnt_file_mode */ - inode->i_mode |= (S_IWUGO & - cifs_sb->mnt_file_mode); - /* BB add code here - - validate if device or weird share or device type? */ - } + } else if ((cifs_sb->mnt_cifs_flags & CIFS_MOUNT_UNX_EMUL) && + (cifsInfo->cifsAttrs & ATTR_SYSTEM)) { + if (decode_sfu_inode(inode, le64_to_cpu(pfindData->EndOfFile), + full_path, cifs_sb, xid)) + cFYI(1, ("Unrecognized sfu inode type")); - spin_lock(&inode->i_lock); - if (is_size_safe_to_change(cifsInfo, - le64_to_cpu(pfindData->EndOfFile))) { - /* can not safely shrink the file size here if the - client is writing to it due to potential races */ - i_size_write(inode, le64_to_cpu(pfindData->EndOfFile)); - - /* 512 bytes (2**9) is the fake blocksize that must be - used for this calculation */ - inode->i_blocks = (512 - 1 + le64_to_cpu( - pfindData->AllocationSize)) >> 9; - } - spin_unlock(&inode->i_lock); + cFYI(1, ("sfu mode 0%o", inode->i_mode)); + } else { + inode->i_mode |= S_IFREG; + /* treat dos attribute of read-only as read-only mode eg 555 */ + if (cifsInfo->cifsAttrs & ATTR_READONLY) + inode->i_mode &= ~(S_IWUGO); + else if ((inode->i_mode & S_IWUGO) == 0) + /* the ATTR_READONLY flag may have been */ + /* changed on server -- set any w bits */ + /* allowed by mnt_file_mode */ + inode->i_mode |= (S_IWUGO & cifs_sb->mnt_file_mode); + /* BB add code to validate if device or weird share or device type? */ + } + + spin_lock(&inode->i_lock); + if (is_size_safe_to_change(cifsInfo, + le64_to_cpu(pfindData->EndOfFile))) { + /* can not safely shrink the file size here if the + client is writing to it due to potential races */ + i_size_write(inode, le64_to_cpu(pfindData->EndOfFile)); + + /* 512 bytes (2**9) is the fake blocksize that must be + used for this calculation */ + inode->i_blocks = (512 - 1 + le64_to_cpu( + pfindData->AllocationSize)) >> 9; + } + spin_unlock(&inode->i_lock); - inode->i_nlink = le32_to_cpu(pfindData->NumberOfLinks); + inode->i_nlink = le32_to_cpu(pfindData->NumberOfLinks); - /* BB fill in uid and gid here? with help from winbind? - or retrieve from NTFS stream extended attribute */ + /* BB fill in uid and gid here? with help from winbind? + or retrieve from NTFS stream extended attribute */ #ifdef CONFIG_CIFS_EXPERIMENTAL - /* fill in 0777 bits from ACL */ - if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_CIFS_ACL) { - cFYI(1, ("Getting mode bits from ACL")); - acl_to_uid_mode(inode, full_path, pfid); - } + /* fill in 0777 bits from ACL */ + if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_CIFS_ACL) { + cFYI(1, ("Getting mode bits from ACL")); + acl_to_uid_mode(inode, full_path, pfid); + } #endif - if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_UNX_EMUL) { - /* fill in remaining high mode bits e.g. SUID, VTX */ - get_sfu_mode(inode, full_path, cifs_sb, xid); - } else if (atomic_read(&cifsInfo->inUse) == 0) { - inode->i_uid = cifs_sb->mnt_uid; - inode->i_gid = cifs_sb->mnt_gid; - /* set so we do not keep refreshing these fields with - bad data after user has changed them in memory */ - atomic_set(&cifsInfo->inUse, 1); - } - - cifs_set_ops(inode, is_dfs_referral); + if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_UNX_EMUL) { + /* fill in remaining high mode bits e.g. SUID, VTX */ + get_sfu_mode(inode, full_path, cifs_sb, xid); + } else if (atomic_read(&cifsInfo->inUse) == 0) { + inode->i_uid = cifs_sb->mnt_uid; + inode->i_gid = cifs_sb->mnt_gid; + /* set so we do not keep refreshing these fields with + bad data after user has changed them in memory */ + atomic_set(&cifsInfo->inUse, 1); } + + cifs_set_ops(inode, is_dfs_referral); + + + + cgii_exit: kfree(buf); return rc; |