summaryrefslogtreecommitdiffstats
path: root/drivers/scsi
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/scsi')
-rw-r--r--drivers/scsi/mpt2sas/Kconfig6
-rw-r--r--drivers/scsi/mpt3sas/Kconfig6
-rw-r--r--drivers/scsi/mpt3sas/mpt3sas_base.c10
-rw-r--r--drivers/scsi/mpt3sas/mpt3sas_config.c6
-rw-r--r--drivers/scsi/mpt3sas/mpt3sas_ctl.c10
-rw-r--r--drivers/scsi/mpt3sas/mpt3sas_debug.h16
-rw-r--r--drivers/scsi/mpt3sas/mpt3sas_scsih.c39
7 files changed, 10 insertions, 83 deletions
diff --git a/drivers/scsi/mpt2sas/Kconfig b/drivers/scsi/mpt2sas/Kconfig
index 657b45ca04c5..1356a0aa5d14 100644
--- a/drivers/scsi/mpt2sas/Kconfig
+++ b/drivers/scsi/mpt2sas/Kconfig
@@ -59,9 +59,3 @@ config SCSI_MPT2SAS_MAX_SGE
SAFE_PHYS_SEGMENTS. However, it may decreased down to 16.
Decreasing this parameter will reduce memory requirements
on a per controller instance.
-
-config SCSI_MPT2SAS_LOGGING
- bool "LSI MPT Fusion logging facility"
- depends on PCI && SCSI && SCSI_MPT2SAS
- ---help---
- This turns on a logging facility.
diff --git a/drivers/scsi/mpt3sas/Kconfig b/drivers/scsi/mpt3sas/Kconfig
index 4d235dd741bf..18b64bce10cb 100644
--- a/drivers/scsi/mpt3sas/Kconfig
+++ b/drivers/scsi/mpt3sas/Kconfig
@@ -59,9 +59,3 @@ config SCSI_MPT3SAS_MAX_SGE
MAX_PHYS_SEGMENTS in most kernels. However in SuSE kernels this
can be 256. However, it may decreased down to 16. Decreasing this
parameter will reduce memory requirements on a per controller instance.
-
-config SCSI_MPT3SAS_LOGGING
- bool "LSI MPT Fusion logging facility"
- depends on PCI && SCSI && SCSI_MPT3SAS
- ---help---
- This turns on a logging facility.
diff --git a/drivers/scsi/mpt3sas/mpt3sas_base.c b/drivers/scsi/mpt3sas/mpt3sas_base.c
index 8a7f93ed2927..31d0ca86beb8 100644
--- a/drivers/scsi/mpt3sas/mpt3sas_base.c
+++ b/drivers/scsi/mpt3sas/mpt3sas_base.c
@@ -324,7 +324,6 @@ mpt3sas_halt_firmware(struct MPT3SAS_ADAPTER *ioc)
panic("panic in %s\n", __func__);
}
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
/**
* _base_sas_ioc_info - verbose translation of the ioc status
* @ioc: per adapter object
@@ -630,7 +629,6 @@ _base_display_event_data(struct MPT3SAS_ADAPTER *ioc,
pr_info(MPT3SAS_FMT "%s\n", ioc->name, desc);
}
-#endif
/**
* _base_sas_log_info - verbose translation of firmware log info
@@ -710,13 +708,13 @@ _base_display_reply_info(struct MPT3SAS_ADAPTER *ioc, u16 smid, u8 msix_index,
return;
}
ioc_status = le16_to_cpu(mpi_reply->IOCStatus);
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
+
if ((ioc_status & MPI2_IOCSTATUS_MASK) &&
(ioc->logging_level & MPT_DEBUG_REPLY)) {
_base_sas_ioc_info(ioc , mpi_reply,
mpt3sas_base_get_msg_frame(ioc, smid));
}
-#endif
+
if (ioc_status & MPI2_IOCSTATUS_FLAG_LOG_INFO_AVAILABLE) {
loginfo = le32_to_cpu(mpi_reply->IOCLogInfo);
_base_sas_log_info(ioc, loginfo);
@@ -783,9 +781,9 @@ _base_async_event(struct MPT3SAS_ADAPTER *ioc, u8 msix_index, u32 reply)
return 1;
if (mpi_reply->Function != MPI2_FUNCTION_EVENT_NOTIFICATION)
return 1;
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
+
_base_display_event_data(ioc, mpi_reply);
-#endif
+
if (!(mpi_reply->AckRequired & MPI2_EVENT_NOTIFICATION_ACK_REQUIRED))
goto out;
smid = mpt3sas_base_get_smid(ioc, ioc->base_cb_idx);
diff --git a/drivers/scsi/mpt3sas/mpt3sas_config.c b/drivers/scsi/mpt3sas/mpt3sas_config.c
index e45c4613ef0c..53eb70130621 100644
--- a/drivers/scsi/mpt3sas/mpt3sas_config.c
+++ b/drivers/scsi/mpt3sas/mpt3sas_config.c
@@ -83,7 +83,6 @@ struct config_request {
dma_addr_t page_dma;
};
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
/**
* _config_display_some_debug - debug routine
* @ioc: per adapter object
@@ -173,7 +172,6 @@ _config_display_some_debug(struct MPT3SAS_ADAPTER *ioc, u16 smid,
ioc->name, le16_to_cpu(mpi_reply->IOCStatus),
le32_to_cpu(mpi_reply->IOCLogInfo));
}
-#endif
/**
* _config_alloc_config_dma_memory - obtain physical memory
@@ -255,9 +253,7 @@ mpt3sas_config_done(struct MPT3SAS_ADAPTER *ioc, u16 smid, u8 msix_index,
mpi_reply->MsgLength*4);
}
ioc->config_cmds.status &= ~MPT3_CMD_PENDING;
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
_config_display_some_debug(ioc, smid, "config_done", mpi_reply);
-#endif
ioc->config_cmds.smid = USHRT_MAX;
complete(&ioc->config_cmds.done);
return 1;
@@ -387,9 +383,7 @@ _config_request(struct MPT3SAS_ADAPTER *ioc, Mpi2ConfigRequest_t
config_request = mpt3sas_base_get_msg_frame(ioc, smid);
ioc->config_cmds.smid = smid;
memcpy(config_request, mpi_request, sizeof(Mpi2ConfigRequest_t));
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
_config_display_some_debug(ioc, smid, "config_request", NULL);
-#endif
init_completion(&ioc->config_cmds.done);
mpt3sas_base_put_smid_default(ioc, smid);
timeleft = wait_for_completion_timeout(&ioc->config_cmds.done,
diff --git a/drivers/scsi/mpt3sas/mpt3sas_ctl.c b/drivers/scsi/mpt3sas/mpt3sas_ctl.c
index 8b46cbf9463f..5c08d31f781f 100644
--- a/drivers/scsi/mpt3sas/mpt3sas_ctl.c
+++ b/drivers/scsi/mpt3sas/mpt3sas_ctl.c
@@ -78,7 +78,6 @@ enum block_state {
BLOCKING,
};
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
/**
* _ctl_sas_device_find_by_handle - sas device search
* @ioc: per adapter object
@@ -254,8 +253,6 @@ _ctl_display_some_debug(struct MPT3SAS_ADAPTER *ioc, u16 smid,
}
}
-#endif
-
/**
* mpt3sas_ctl_done - ctl module completion routine
* @ioc: per adapter object
@@ -302,9 +299,7 @@ mpt3sas_ctl_done(struct MPT3SAS_ADAPTER *ioc, u16 smid, u8 msix_index,
}
}
}
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
_ctl_display_some_debug(ioc, smid, "ctl_done", mpi_reply);
-#endif
ioc->ctl_cmds.status &= ~MPT3_CMD_PENDING;
complete(&ioc->ctl_cmds.done);
return 1;
@@ -759,9 +754,7 @@ _ctl_do_mpt_command(struct MPT3SAS_ADAPTER *ioc, struct mpt3_ioctl_command karg,
psge = (void *)request + (karg.data_sge_offset*4);
/* send command to firmware */
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
_ctl_display_some_debug(ioc, smid, "ctl_request", NULL);
-#endif
init_completion(&ioc->ctl_cmds.done);
switch (mpi_request->Function) {
@@ -916,7 +909,6 @@ _ctl_do_mpt_command(struct MPT3SAS_ADAPTER *ioc, struct mpt3_ioctl_command karg,
mpi_reply = ioc->ctl_cmds.reply;
ioc_status = le16_to_cpu(mpi_reply->IOCStatus) & MPI2_IOCSTATUS_MASK;
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
if (mpi_reply->Function == MPI2_FUNCTION_SCSI_TASK_MGMT &&
(ioc->logging_level & MPT_DEBUG_TM)) {
Mpi2SCSITaskManagementReply_t *tm_reply =
@@ -929,7 +921,7 @@ _ctl_do_mpt_command(struct MPT3SAS_ADAPTER *ioc, struct mpt3_ioctl_command karg,
le32_to_cpu(tm_reply->IOCLogInfo),
le32_to_cpu(tm_reply->TerminationCount));
}
-#endif
+
/* copy out xdata to user */
if (data_in_sz) {
if (copy_to_user(karg.data_in_buf_ptr, data_in,
diff --git a/drivers/scsi/mpt3sas/mpt3sas_debug.h b/drivers/scsi/mpt3sas/mpt3sas_debug.h
index 4e8a63fdb304..cceeb2c16e64 100644
--- a/drivers/scsi/mpt3sas/mpt3sas_debug.h
+++ b/drivers/scsi/mpt3sas/mpt3sas_debug.h
@@ -68,20 +68,11 @@
#define MPT_DEBUG_TRIGGER_DIAG 0x00200000
-/*
- * CONFIG_SCSI_MPT3SAS_LOGGING - enabled in Kconfig
- */
-
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
#define MPT_CHECK_LOGGING(IOC, CMD, BITS) \
{ \
if (IOC->logging_level & BITS) \
CMD; \
}
-#else
-#define MPT_CHECK_LOGGING(IOC, CMD, BITS)
-#endif /* CONFIG_SCSI_MPT3SAS_LOGGING */
-
/*
* debug macros
@@ -153,7 +144,7 @@
/* inline functions for dumping debug data*/
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
+
/**
* _debug_dump_mf - print message frame contents
* @mpi_request: pointer to message frame
@@ -211,10 +202,5 @@ _debug_dump_config(void *mpi_request, int sz)
}
pr_info("\n");
}
-#else
-#define _debug_dump_mf(mpi_request, sz)
-#define _debug_dump_reply(mpi_request, sz)
-#define _debug_dump_config(mpi_request, sz)
-#endif /* CONFIG_SCSI_MPT3SAS_LOGGING */
#endif /* MPT3SAS_DEBUG_H_INCLUDED */
diff --git a/drivers/scsi/mpt3sas/mpt3sas_scsih.c b/drivers/scsi/mpt3sas/mpt3sas_scsih.c
index 233627d23d0f..a638920dbfb3 100644
--- a/drivers/scsi/mpt3sas/mpt3sas_scsih.c
+++ b/drivers/scsi/mpt3sas/mpt3sas_scsih.c
@@ -3624,10 +3624,8 @@ scsih_qcmd(struct Scsi_Host *shost, struct scsi_cmnd *scmd)
u16 smid;
u16 handle;
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
if (ioc->logging_level & MPT_DEBUG_SCSI)
scsi_print_command(scmd);
-#endif
sas_device_priv_data = scmd->device->hostdata;
if (!sas_device_priv_data || !sas_device_priv_data->sas_target) {
@@ -3758,7 +3756,6 @@ _scsih_normalize_sense(char *sense_buffer, struct sense_info *data)
}
}
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
/**
* _scsih_scsi_ioc_info - translated non-succesfull SCSI_IO request
* @ioc: per adapter object
@@ -3971,7 +3968,6 @@ _scsih_scsi_ioc_info(struct MPT3SAS_ADAPTER *ioc, struct scsi_cmnd *scmd,
_scsih_response_code(ioc, response_bytes[0]);
}
}
-#endif
/**
* _scsih_turn_on_pfa_led - illuminate PFA LED
@@ -4239,13 +4235,11 @@ _scsih_io_done(struct MPT3SAS_ADAPTER *ioc, u16 smid, u8 msix_index, u32 reply)
le16_to_cpu(mpi_reply->DevHandle));
mpt3sas_trigger_scsi(ioc, data.skey, data.asc, data.ascq);
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
if (!(ioc->logging_level & MPT_DEBUG_REPLY) &&
((scmd->sense_buffer[2] == UNIT_ATTENTION) ||
(scmd->sense_buffer[2] == MEDIUM_ERROR) ||
(scmd->sense_buffer[2] == HARDWARE_ERROR)))
_scsih_scsi_ioc_info(ioc, scmd, mpi_reply, smid);
-#endif
}
switch (ioc_status) {
case MPI2_IOCSTATUS_BUSY:
@@ -4352,10 +4346,8 @@ _scsih_io_done(struct MPT3SAS_ADAPTER *ioc, u16 smid, u8 msix_index, u32 reply)
}
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
if (scmd->result && (ioc->logging_level & MPT_DEBUG_REPLY))
_scsih_scsi_ioc_info(ioc , scmd, mpi_reply, smid);
-#endif
out:
@@ -5152,7 +5144,6 @@ _scsih_remove_device(struct MPT3SAS_ADAPTER *ioc,
kfree(sas_device);
}
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
/**
* _scsih_sas_topology_change_event_debug - debug for topology event
* @ioc: per adapter object
@@ -5230,7 +5221,6 @@ _scsih_sas_topology_change_event_debug(struct MPT3SAS_ADAPTER *ioc,
}
}
-#endif
/**
* _scsih_sas_topology_change_event - handle topology changes
@@ -5255,10 +5245,8 @@ _scsih_sas_topology_change_event(struct MPT3SAS_ADAPTER *ioc,
(Mpi2EventDataSasTopologyChangeList_t *)
fw_event->event_data;
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK)
_scsih_sas_topology_change_event_debug(ioc, event_data);
-#endif
if (ioc->shost_recovery || ioc->remove_host || ioc->pci_error_recovery)
return 0;
@@ -5364,7 +5352,6 @@ _scsih_sas_topology_change_event(struct MPT3SAS_ADAPTER *ioc,
return 0;
}
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
/**
* _scsih_sas_device_status_change_event_debug - debug for device event
* @event_data: event data payload
@@ -5432,7 +5419,6 @@ _scsih_sas_device_status_change_event_debug(struct MPT3SAS_ADAPTER *ioc,
event_data->ASC, event_data->ASCQ);
pr_info("\n");
}
-#endif
/**
* _scsih_sas_device_status_change_event - handle device status change
@@ -5454,11 +5440,9 @@ _scsih_sas_device_status_change_event(struct MPT3SAS_ADAPTER *ioc,
(Mpi2EventDataSasDeviceStatusChange_t *)
fw_event->event_data;
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK)
_scsih_sas_device_status_change_event_debug(ioc,
event_data);
-#endif
/* In MPI Revision K (0xC), the internal device reset complete was
* implemented, so avoid setting tm_busy flag for older firmware.
@@ -5496,7 +5480,6 @@ _scsih_sas_device_status_change_event(struct MPT3SAS_ADAPTER *ioc,
spin_unlock_irqrestore(&ioc->sas_device_lock, flags);
}
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
/**
* _scsih_sas_enclosure_dev_status_change_event_debug - debug for enclosure
* event
@@ -5531,7 +5514,6 @@ _scsih_sas_enclosure_dev_status_change_event_debug(struct MPT3SAS_ADAPTER *ioc,
(unsigned long long)le64_to_cpu(event_data->EnclosureLogicalID),
le16_to_cpu(event_data->StartSlot));
}
-#endif
/**
* _scsih_sas_enclosure_dev_status_change_event - handle enclosure events
@@ -5545,12 +5527,10 @@ static void
_scsih_sas_enclosure_dev_status_change_event(struct MPT3SAS_ADAPTER *ioc,
struct fw_event_work *fw_event)
{
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK)
_scsih_sas_enclosure_dev_status_change_event_debug(ioc,
(Mpi2EventDataSasEnclDevStatusChange_t *)
fw_event->event_data);
-#endif
}
/**
@@ -5730,17 +5710,15 @@ _scsih_sas_discovery_event(struct MPT3SAS_ADAPTER *ioc,
Mpi2EventDataSasDiscovery_t *event_data =
(Mpi2EventDataSasDiscovery_t *) fw_event->event_data;
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK) {
pr_info(MPT3SAS_FMT "discovery event: (%s)", ioc->name,
(event_data->ReasonCode == MPI2_EVENT_SAS_DISC_RC_STARTED) ?
"start" : "stop");
- if (event_data->DiscoveryStatus)
- pr_info("discovery_status(0x%08x)",
- le32_to_cpu(event_data->DiscoveryStatus));
- pr_info("\n");
+ if (event_data->DiscoveryStatus)
+ pr_info("discovery_status(0x%08x)",
+ le32_to_cpu(event_data->DiscoveryStatus));
+ pr_info("\n");
}
-#endif
if (event_data->ReasonCode == MPI2_EVENT_SAS_DISC_RC_STARTED &&
!ioc->sas_hba.num_phys) {
@@ -6117,7 +6095,6 @@ _scsih_sas_pd_add(struct MPT3SAS_ADAPTER *ioc,
_scsih_add_device(ioc, handle, 0, 1);
}
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
/**
* _scsih_sas_ir_config_change_event_debug - debug for IR Config Change events
* @ioc: per adapter object
@@ -6197,7 +6174,6 @@ _scsih_sas_ir_config_change_event_debug(struct MPT3SAS_ADAPTER *ioc,
element->PhysDiskNum);
}
}
-#endif
/**
* _scsih_sas_ir_config_change_event - handle ir configuration change events
@@ -6218,12 +6194,9 @@ _scsih_sas_ir_config_change_event(struct MPT3SAS_ADAPTER *ioc,
(Mpi2EventDataIrConfigChangeList_t *)
fw_event->event_data;
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK)
_scsih_sas_ir_config_change_event_debug(ioc, event_data);
-#endif
-
foreign_config = (le32_to_cpu(event_data->Flags) &
MPI2_EVENT_IR_CHANGE_FLAGS_FOREIGN_CONFIG) ? 1 : 0;
@@ -6435,7 +6408,6 @@ _scsih_sas_ir_physical_disk_event(struct MPT3SAS_ADAPTER *ioc,
}
}
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
/**
* _scsih_sas_ir_operation_status_event_debug - debug for IR op event
* @ioc: per adapter object
@@ -6477,7 +6449,6 @@ _scsih_sas_ir_operation_status_event_debug(struct MPT3SAS_ADAPTER *ioc,
le16_to_cpu(event_data->VolDevHandle),
event_data->PercentComplete);
}
-#endif
/**
* _scsih_sas_ir_operation_status_event - handle RAID operation events
@@ -6498,11 +6469,9 @@ _scsih_sas_ir_operation_status_event(struct MPT3SAS_ADAPTER *ioc,
unsigned long flags;
u16 handle;
-#ifdef CONFIG_SCSI_MPT3SAS_LOGGING
if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK)
_scsih_sas_ir_operation_status_event_debug(ioc,
event_data);
-#endif
/* code added for raid transport support */
if (event_data->RAIDOperation == MPI2_EVENT_IR_RAIDOP_RESYNC) {