diff options
Diffstat (limited to 'Documentation/ABI/testing/sysfs-bus-iio')
-rw-r--r-- | Documentation/ABI/testing/sysfs-bus-iio | 42 |
1 files changed, 42 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio index 6ad47a67521c..c551301b33f1 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio +++ b/Documentation/ABI/testing/sysfs-bus-iio @@ -429,6 +429,7 @@ What: /sys/bus/iio/devices/iio:deviceX/in_angl_scale What: /sys/bus/iio/devices/iio:deviceX/in_intensity_x_scale What: /sys/bus/iio/devices/iio:deviceX/in_intensity_y_scale What: /sys/bus/iio/devices/iio:deviceX/in_intensity_z_scale +What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_scale KernelVersion: 2.6.35 Contact: linux-iio@vger.kernel.org Description: @@ -1957,3 +1958,44 @@ Description: Specify the percent for light sensor relative to the channel absolute value that a data field should change before an event is generated. Units are a percentage of the prior reading. + +What: /sys/bus/iio/devices/iio:deviceX/calibration_auto_enable +Date: June 2020 +KernelVersion: 5.8 +Contact: linux-iio@vger.kernel.org +Description: + Some sensors have the ability to apply auto calibration at + runtime. For example, it may be necessary to compensate for + contaminant build-up in a measurement chamber or optical + element deterioration that would otherwise lead to sensor drift. + + Writing 1 or 0 to this attribute will respectively activate or + deactivate this auto calibration function. + + Upon reading, the current status is returned. + +What: /sys/bus/iio/devices/iio:deviceX/calibration_forced_value +Date: June 2020 +KernelVersion: 5.8 +Contact: linux-iio@vger.kernel.org +Description: + Some sensors have the ability to apply a manual calibration using + a known measurement value, perhaps obtained from an external + reference device. + + Writing a value to this function will force such a calibration + change. For the scd30 the value should be from the range + [400 1 2000]. + + Note for the scd30 that a valid value may only be obtained once + it is has been written. Until then any read back of this value + should be ignored. As for the scd4x an error will be returned + immediately if the manual calibration has failed. + +What: /sys/bus/iio/devices/iio:deviceX/calibration_forced_value_available +KernelVersion: 5.15 +Contact: linux-iio@vger.kernel.org +Description: + Available range for the forced calibration value, expressed as: + + - a range specified as "[min step max]" |