summaryrefslogtreecommitdiffstats
path: root/net
diff options
context:
space:
mode:
authorNeil Horman <nhorman@tuxdriver.com>2012-05-01 08:18:02 +0000
committerDavid S. Miller <davem@davemloft.net>2012-05-02 21:02:48 -0400
commit4fdcfa12843bca38d0c9deff70c8720e4e8f515f (patch)
tree3ef2a92b1d6d322f9b72185e58b9d35a15564692 /net
parenta4723848d05dd31d298c551fb77ad28481309999 (diff)
downloadlinux-4fdcfa12843bca38d0c9deff70c8720e4e8f515f.tar.bz2
drop_monitor: prevent init path from scheduling on the wrong cpu
I just noticed after some recent updates, that the init path for the drop monitor protocol has a minor error. drop monitor maintains a per cpu structure, that gets initalized from a single cpu. Normally this is fine, as the protocol isn't in use yet, but I recently made a change that causes a failed skb allocation to reschedule itself . Given the current code, the implication is that this workqueue reschedule will take place on the wrong cpu. If drop monitor is used early during the boot process, its possible that two cpus will access a single per-cpu structure in parallel, possibly leading to data corruption. This patch fixes the situation, by storing the cpu number that a given instance of this per-cpu data should be accessed from. In the case of a need for a reschedule, the cpu stored in the struct is assigned the rescheule, rather than the currently executing cpu Tested successfully by myself. Signed-off-by: Neil Horman <nhorman@tuxdriver.com> CC: David Miller <davem@davemloft.net> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'net')
-rw-r--r--net/core/drop_monitor.c12
1 files changed, 7 insertions, 5 deletions
diff --git a/net/core/drop_monitor.c b/net/core/drop_monitor.c
index 7592943513e3..a7cad741df01 100644
--- a/net/core/drop_monitor.c
+++ b/net/core/drop_monitor.c
@@ -49,6 +49,7 @@ struct per_cpu_dm_data {
struct sk_buff __rcu *skb;
atomic_t dm_hit_count;
struct timer_list send_timer;
+ int cpu;
};
struct dm_hw_stat_delta {
@@ -73,7 +74,6 @@ static int dm_hit_limit = 64;
static int dm_delay = 1;
static unsigned long dm_hw_check_delta = 2*HZ;
static LIST_HEAD(hw_stats_list);
-static int initialized = 0;
static void reset_per_cpu_data(struct per_cpu_dm_data *data)
{
@@ -96,8 +96,8 @@ static void reset_per_cpu_data(struct per_cpu_dm_data *data)
sizeof(struct net_dm_alert_msg));
msg = nla_data(nla);
memset(msg, 0, al);
- } else if (initialized)
- schedule_work_on(smp_processor_id(), &data->dm_alert_work);
+ } else
+ schedule_work_on(data->cpu, &data->dm_alert_work);
/*
* Don't need to lock this, since we are guaranteed to only
@@ -121,6 +121,8 @@ static void send_dm_alert(struct work_struct *unused)
struct sk_buff *skb;
struct per_cpu_dm_data *data = &get_cpu_var(dm_cpu_data);
+ WARN_ON_ONCE(data->cpu != smp_processor_id());
+
/*
* Grab the skb we're about to send
*/
@@ -404,14 +406,14 @@ static int __init init_net_drop_monitor(void)
for_each_present_cpu(cpu) {
data = &per_cpu(dm_cpu_data, cpu);
- reset_per_cpu_data(data);
+ data->cpu = cpu;
INIT_WORK(&data->dm_alert_work, send_dm_alert);
init_timer(&data->send_timer);
data->send_timer.data = cpu;
data->send_timer.function = sched_send_work;
+ reset_per_cpu_data(data);
}
- initialized = 1;
goto out;