diff options
author | Andreas Gruenbacher <agruenba@redhat.com> | 2018-02-28 12:48:53 -0700 |
---|---|---|
committer | Bob Peterson <rpeterso@redhat.com> | 2018-03-08 09:26:20 -0700 |
commit | 83998ccd9bfff881f04ce03f6964f8a83e6c5b54 (patch) | |
tree | 0d7ce75cf2531a013e58d0681daa596c5b36fe32 /fs/gfs2/inode.c | |
parent | 174d1232ebc84fcde8f5889d1171c9c7e74a10a7 (diff) | |
download | linux-83998ccd9bfff881f04ce03f6964f8a83e6c5b54.tar.bz2 |
gfs2: Dirty source inode during rename
Mark the source inode dirty during a rename instead of just updating the
underlying buffer head. Otherwise, fsync may find the inode clean and
will then skip flushing the journal. A subsequent power failure will
cause the rename to be lost. This happens in command sequences like:
xfs_io -f -c 'pwrite 0 4096' -c 'fsync' foo
mv foo bar
xfs_io -c 'fsync' bar
# power failure
Fixes xfstests generic/322, generic/376.
Signed-off-by: Andreas Gruenbacher <agruenba@redhat.com>
Signed-off-by: Bob Peterson <rpeterso@redhat.com>
Diffstat (limited to 'fs/gfs2/inode.c')
-rw-r--r-- | fs/gfs2/inode.c | 10 |
1 files changed, 1 insertions, 9 deletions
diff --git a/fs/gfs2/inode.c b/fs/gfs2/inode.c index 59e0560180ec..8700eb815638 100644 --- a/fs/gfs2/inode.c +++ b/fs/gfs2/inode.c @@ -1326,19 +1326,11 @@ static int gfs2_ok_to_move(struct gfs2_inode *this, struct gfs2_inode *to) static int update_moved_ino(struct gfs2_inode *ip, struct gfs2_inode *ndip, int dir_rename) { - int error; - struct buffer_head *dibh; - if (dir_rename) return gfs2_dir_mvino(ip, &gfs2_qdotdot, ndip, DT_DIR); - error = gfs2_meta_inode_buffer(ip, &dibh); - if (error) - return error; ip->i_inode.i_ctime = current_time(&ip->i_inode); - gfs2_trans_add_meta(ip->i_gl, dibh); - gfs2_dinode_out(ip, dibh->b_data); - brelse(dibh); + mark_inode_dirty_sync(&ip->i_inode); return 0; } |