diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2019-03-24 10:01:53 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2019-03-24 10:01:53 -0700 |
commit | 9fc13bbdf1d6b518c8377633c5fb198fbc9dcc03 (patch) | |
tree | 5134d446845452a89bb142480223fc36b2901e5e /drivers | |
parent | 38104c00200898120e12a73db27cea2b7055ea3c (diff) | |
parent | 2d7c4e17811f766321b9c054609551fa40f0b445 (diff) | |
download | linux-9fc13bbdf1d6b518c8377633c5fb198fbc9dcc03.tar.bz2 |
Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management fixes from Zhang Rui:
- Fix a wrong __percpu structure declaration in intel_powerclamp driver
(Luc Van Oostenryck)
- Fix truncated name of the idle injection kthreads created by
intel_powerclamp driver (Zhang Rui)
- Fix the missing UUID supports in int3400 thermal driver (Matthew
Garrett)
- Fix a crash when accessing the debugfs of bcm2835 SoC thermal driver
(Phil Elwell)
- A couple of trivial fixes/cleanups in some SoC thermal drivers
* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux:
thermal/intel_powerclamp: fix truncated kthread name
thermal: mtk: Allocate enough space for mtk_thermal.
thermal/int340x_thermal: fix mode setting
thermal/int340x_thermal: Add additional UUIDs
thermal: cpu_cooling: Remove unused cur_freq variable
thermal: bcm2835: Fix crash in bcm2835_thermal_debugfs
thermal: samsung: Fix incorrect check after code merge
thermal/intel_powerclamp: fix __percpu declaration of worker_data
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/thermal/broadcom/bcm2835_thermal.c | 9 | ||||
-rw-r--r-- | drivers/thermal/cpu_cooling.c | 3 | ||||
-rw-r--r-- | drivers/thermal/intel/int340x_thermal/int3400_thermal.c | 21 | ||||
-rw-r--r-- | drivers/thermal/intel/intel_powerclamp.c | 4 | ||||
-rw-r--r-- | drivers/thermal/mtk_thermal.c | 7 | ||||
-rw-r--r-- | drivers/thermal/samsung/exynos_tmu.c | 2 |
6 files changed, 30 insertions, 16 deletions
diff --git a/drivers/thermal/broadcom/bcm2835_thermal.c b/drivers/thermal/broadcom/bcm2835_thermal.c index 720760cd493f..ba39647a690c 100644 --- a/drivers/thermal/broadcom/bcm2835_thermal.c +++ b/drivers/thermal/broadcom/bcm2835_thermal.c @@ -119,8 +119,7 @@ static const struct debugfs_reg32 bcm2835_thermal_regs[] = { static void bcm2835_thermal_debugfs(struct platform_device *pdev) { - struct thermal_zone_device *tz = platform_get_drvdata(pdev); - struct bcm2835_thermal_data *data = tz->devdata; + struct bcm2835_thermal_data *data = platform_get_drvdata(pdev); struct debugfs_regset32 *regset; data->debugfsdir = debugfs_create_dir("bcm2835_thermal", NULL); @@ -266,7 +265,7 @@ static int bcm2835_thermal_probe(struct platform_device *pdev) data->tz = tz; - platform_set_drvdata(pdev, tz); + platform_set_drvdata(pdev, data); /* * Thermal_zone doesn't enable hwmon as default, @@ -290,8 +289,8 @@ err_clk: static int bcm2835_thermal_remove(struct platform_device *pdev) { - struct thermal_zone_device *tz = platform_get_drvdata(pdev); - struct bcm2835_thermal_data *data = tz->devdata; + struct bcm2835_thermal_data *data = platform_get_drvdata(pdev); + struct thermal_zone_device *tz = data->tz; debugfs_remove_recursive(data->debugfsdir); thermal_zone_of_sensor_unregister(&pdev->dev, tz); diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 6fff16113628..f7c1f49ec87f 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -536,12 +536,11 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev, struct thermal_zone_device *tz, u32 power, unsigned long *state) { - unsigned int cur_freq, target_freq; + unsigned int target_freq; u32 last_load, normalised_power; struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; struct cpufreq_policy *policy = cpufreq_cdev->policy; - cur_freq = cpufreq_quick_get(policy->cpu); power = power > 0 ? power : 0; last_load = cpufreq_cdev->last_load ?: 1; normalised_power = (power * 100) / last_load; diff --git a/drivers/thermal/intel/int340x_thermal/int3400_thermal.c b/drivers/thermal/intel/int340x_thermal/int3400_thermal.c index 61ca7ce3624e..5f3ed24e26ec 100644 --- a/drivers/thermal/intel/int340x_thermal/int3400_thermal.c +++ b/drivers/thermal/intel/int340x_thermal/int3400_thermal.c @@ -22,6 +22,13 @@ enum int3400_thermal_uuid { INT3400_THERMAL_PASSIVE_1, INT3400_THERMAL_ACTIVE, INT3400_THERMAL_CRITICAL, + INT3400_THERMAL_ADAPTIVE_PERFORMANCE, + INT3400_THERMAL_EMERGENCY_CALL_MODE, + INT3400_THERMAL_PASSIVE_2, + INT3400_THERMAL_POWER_BOSS, + INT3400_THERMAL_VIRTUAL_SENSOR, + INT3400_THERMAL_COOLING_MODE, + INT3400_THERMAL_HARDWARE_DUTY_CYCLING, INT3400_THERMAL_MAXIMUM_UUID, }; @@ -29,6 +36,13 @@ static char *int3400_thermal_uuids[INT3400_THERMAL_MAXIMUM_UUID] = { "42A441D6-AE6A-462b-A84B-4A8CE79027D3", "3A95C389-E4B8-4629-A526-C52C88626BAE", "97C68AE7-15FA-499c-B8C9-5DA81D606E0A", + "63BE270F-1C11-48FD-A6F7-3AF253FF3E2D", + "5349962F-71E6-431D-9AE8-0A635B710AEE", + "9E04115A-AE87-4D1C-9500-0F3E340BFE75", + "F5A35014-C209-46A4-993A-EB56DE7530A1", + "6ED722A7-9240-48A5-B479-31EEF723D7CF", + "16CAF1B7-DD38-40ED-B1C1-1B8A1913D531", + "BE84BABF-C4D4-403D-B495-3128FD44dAC1", }; struct int3400_thermal_priv { @@ -299,10 +313,9 @@ static int int3400_thermal_probe(struct platform_device *pdev) platform_set_drvdata(pdev, priv); - if (priv->uuid_bitmap & 1 << INT3400_THERMAL_PASSIVE_1) { - int3400_thermal_ops.get_mode = int3400_thermal_get_mode; - int3400_thermal_ops.set_mode = int3400_thermal_set_mode; - } + int3400_thermal_ops.get_mode = int3400_thermal_get_mode; + int3400_thermal_ops.set_mode = int3400_thermal_set_mode; + priv->thermal = thermal_zone_device_register("INT3400 Thermal", 0, 0, priv, &int3400_thermal_ops, &int3400_thermal_params, 0, 0); diff --git a/drivers/thermal/intel/intel_powerclamp.c b/drivers/thermal/intel/intel_powerclamp.c index 7571f7c2e7c9..ac7256b5f020 100644 --- a/drivers/thermal/intel/intel_powerclamp.c +++ b/drivers/thermal/intel/intel_powerclamp.c @@ -101,7 +101,7 @@ struct powerclamp_worker_data { bool clamping; }; -static struct powerclamp_worker_data * __percpu worker_data; +static struct powerclamp_worker_data __percpu *worker_data; static struct thermal_cooling_device *cooling_dev; static unsigned long *cpu_clamping_mask; /* bit map for tracking per cpu * clamping kthread worker @@ -494,7 +494,7 @@ static void start_power_clamp_worker(unsigned long cpu) struct powerclamp_worker_data *w_data = per_cpu_ptr(worker_data, cpu); struct kthread_worker *worker; - worker = kthread_create_worker_on_cpu(cpu, 0, "kidle_inject/%ld", cpu); + worker = kthread_create_worker_on_cpu(cpu, 0, "kidle_inj/%ld", cpu); if (IS_ERR(worker)) return; diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c index 5c07a61447d3..e4ea7f6aef20 100644 --- a/drivers/thermal/mtk_thermal.c +++ b/drivers/thermal/mtk_thermal.c @@ -199,6 +199,9 @@ enum { #define MT7622_TS1 0 #define MT7622_NUM_CONTROLLER 1 +/* The maximum number of banks */ +#define MAX_NUM_ZONES 8 + /* The calibration coefficient of sensor */ #define MT7622_CALIBRATION 165 @@ -249,7 +252,7 @@ struct mtk_thermal_data { const int num_controller; const int *controller_offset; bool need_switch_bank; - struct thermal_bank_cfg bank_data[]; + struct thermal_bank_cfg bank_data[MAX_NUM_ZONES]; }; struct mtk_thermal { @@ -268,7 +271,7 @@ struct mtk_thermal { s32 vts[MAX_NUM_VTS]; const struct mtk_thermal_data *conf; - struct mtk_thermal_bank banks[]; + struct mtk_thermal_bank banks[MAX_NUM_ZONES]; }; /* MT8183 thermal sensor data */ diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c index 48eef552cba4..fc9399d9c082 100644 --- a/drivers/thermal/samsung/exynos_tmu.c +++ b/drivers/thermal/samsung/exynos_tmu.c @@ -666,7 +666,7 @@ static int exynos_get_temp(void *p, int *temp) struct exynos_tmu_data *data = p; int value, ret = 0; - if (!data || !data->tmu_read || !data->enabled) + if (!data || !data->tmu_read) return -EINVAL; else if (!data->enabled) /* |