diff options
author | Heiner Kallweit <heiner.kallweit@web.de> | 2014-11-08 20:35:54 +0100 |
---|---|---|
committer | Eduardo Valentin <edubezval@gmail.com> | 2014-11-09 15:42:53 -0400 |
commit | 90a21ff5824c3ae8b49c1c0498b137792b935aab (patch) | |
tree | 6ed150cd27b31178e040f3ed56fefd840da2ae1c /drivers/thermal | |
parent | 1d6a27775762110d675f71d7192972c7357b99a7 (diff) | |
download | linux-90a21ff5824c3ae8b49c1c0498b137792b935aab.tar.bz2 |
imx: thermal: imx_get_temp might be called before sensor clock is prepared
imx_get_temp might be called before the sensor clock is prepared
thus resulting in a timeout of the first attempt to read temp:
thermal thermal_zone0: failed to read out thermal zone 0
Happened to me on a Utilite Standard with IMX6 Dual SoC.
Reason is that in imx_thermal_probe thermal_zone_device_register
is called before the sensor clock is prepared.
thermal_zone_device_register however calls
thermal_zone_device_update which eventually calls imx_get_temp.
Fix this by preparing the clock before calling
thermal_zone_device_register.
Signed-off-by: Heiner Kallweit <heiner.kallweit@web.de>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'drivers/thermal')
-rw-r--r-- | drivers/thermal/imx_thermal.c | 41 |
1 files changed, 25 insertions, 16 deletions
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c index 0e35999ad8b2..5a1f1070b702 100644 --- a/drivers/thermal/imx_thermal.c +++ b/drivers/thermal/imx_thermal.c @@ -525,6 +525,30 @@ static int imx_thermal_probe(struct platform_device *pdev) return ret; } + data->thermal_clk = devm_clk_get(&pdev->dev, NULL); + if (IS_ERR(data->thermal_clk)) { + ret = PTR_ERR(data->thermal_clk); + if (ret != -EPROBE_DEFER) + dev_err(&pdev->dev, + "failed to get thermal clk: %d\n", ret); + cpufreq_cooling_unregister(data->cdev); + return ret; + } + + /* + * Thermal sensor needs clk on to get correct value, normally + * we should enable its clk before taking measurement and disable + * clk after measurement is done, but if alarm function is enabled, + * hardware will auto measure the temperature periodically, so we + * need to keep the clk always on for alarm function. + */ + ret = clk_prepare_enable(data->thermal_clk); + if (ret) { + dev_err(&pdev->dev, "failed to enable thermal clk: %d\n", ret); + cpufreq_cooling_unregister(data->cdev); + return ret; + } + data->tz = thermal_zone_device_register("imx_thermal_zone", IMX_TRIP_NUM, BIT(IMX_TRIP_PASSIVE), data, @@ -535,26 +559,11 @@ static int imx_thermal_probe(struct platform_device *pdev) ret = PTR_ERR(data->tz); dev_err(&pdev->dev, "failed to register thermal zone device %d\n", ret); + clk_disable_unprepare(data->thermal_clk); cpufreq_cooling_unregister(data->cdev); return ret; } - data->thermal_clk = devm_clk_get(&pdev->dev, NULL); - if (IS_ERR(data->thermal_clk)) { - dev_warn(&pdev->dev, "failed to get thermal clk!\n"); - } else { - /* - * Thermal sensor needs clk on to get correct value, normally - * we should enable its clk before taking measurement and disable - * clk after measurement is done, but if alarm function is enabled, - * hardware will auto measure the temperature periodically, so we - * need to keep the clk always on for alarm function. - */ - ret = clk_prepare_enable(data->thermal_clk); - if (ret) - dev_warn(&pdev->dev, "failed to enable thermal clk: %d\n", ret); - } - /* Enable measurements at ~ 10 Hz */ regmap_write(map, TEMPSENSE1 + REG_CLR, TEMPSENSE1_MEASURE_FREQ); measure_freq = DIV_ROUND_UP(32768, 10); /* 10 Hz */ |