summaryrefslogtreecommitdiffstats
path: root/drivers/thermal/thermal_core.c
diff options
context:
space:
mode:
authorEduardo Valentin <edubezval@gmail.com>2016-11-07 21:09:02 -0800
committerZhang Rui <rui.zhang@intel.com>2016-11-23 10:06:12 +0800
commit45cf2ec99c160e5c33402521bcff1a585629230a (patch)
tree1e19b39ad6eacfa8f0dde7db77f7f30b47e931e4 /drivers/thermal/thermal_core.c
parent99ea2eff91080740d91df6ce5bfdfba666a4a035 (diff)
downloadlinux-45cf2ec99c160e5c33402521bcff1a585629230a.tar.bz2
thermal: core: move cooling device sysfs to thermal_sysfs.c
This is a code reorganization, simply to concentrate the sysfs handling functions in thermal_sysfs.c. This patch moves the cooling device handling functions. Cc: Zhang Rui <rui.zhang@intel.com> Cc: linux-pm@vger.kernel.org Cc: linux-kernel@vger.kernel.org Signed-off-by: Eduardo Valentin <edubezval@gmail.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Diffstat (limited to 'drivers/thermal/thermal_core.c')
-rw-r--r--drivers/thermal/thermal_core.c128
1 files changed, 1 insertions, 127 deletions
diff --git a/drivers/thermal/thermal_core.c b/drivers/thermal/thermal_core.c
index d55a41a317b5..fb1902135740 100644
--- a/drivers/thermal/thermal_core.c
+++ b/drivers/thermal/thermal_core.c
@@ -798,132 +798,6 @@ int thermal_build_list_of_policies(char *buf)
return count;
}
-/* sys I/F for cooling device */
-static ssize_t
-thermal_cooling_device_type_show(struct device *dev,
- struct device_attribute *attr, char *buf)
-{
- struct thermal_cooling_device *cdev = to_cooling_device(dev);
-
- return sprintf(buf, "%s\n", cdev->type);
-}
-
-static ssize_t
-thermal_cooling_device_max_state_show(struct device *dev,
- struct device_attribute *attr, char *buf)
-{
- struct thermal_cooling_device *cdev = to_cooling_device(dev);
- unsigned long state;
- int ret;
-
- ret = cdev->ops->get_max_state(cdev, &state);
- if (ret)
- return ret;
- return sprintf(buf, "%ld\n", state);
-}
-
-static ssize_t
-thermal_cooling_device_cur_state_show(struct device *dev,
- struct device_attribute *attr, char *buf)
-{
- struct thermal_cooling_device *cdev = to_cooling_device(dev);
- unsigned long state;
- int ret;
-
- ret = cdev->ops->get_cur_state(cdev, &state);
- if (ret)
- return ret;
- return sprintf(buf, "%ld\n", state);
-}
-
-static ssize_t
-thermal_cooling_device_cur_state_store(struct device *dev,
- struct device_attribute *attr,
- const char *buf, size_t count)
-{
- struct thermal_cooling_device *cdev = to_cooling_device(dev);
- unsigned long state;
- int result;
-
- if (sscanf(buf, "%ld\n", &state) != 1)
- return -EINVAL;
-
- if ((long)state < 0)
- return -EINVAL;
-
- result = cdev->ops->set_cur_state(cdev, state);
- if (result)
- return result;
- return count;
-}
-
-static struct device_attribute dev_attr_cdev_type =
-__ATTR(type, 0444, thermal_cooling_device_type_show, NULL);
-static DEVICE_ATTR(max_state, 0444,
- thermal_cooling_device_max_state_show, NULL);
-static DEVICE_ATTR(cur_state, 0644,
- thermal_cooling_device_cur_state_show,
- thermal_cooling_device_cur_state_store);
-
-static ssize_t
-thermal_cooling_device_trip_point_show(struct device *dev,
- struct device_attribute *attr, char *buf)
-{
- struct thermal_instance *instance;
-
- instance =
- container_of(attr, struct thermal_instance, attr);
-
- if (instance->trip == THERMAL_TRIPS_NONE)
- return sprintf(buf, "-1\n");
- else
- return sprintf(buf, "%d\n", instance->trip);
-}
-
-static struct attribute *cooling_device_attrs[] = {
- &dev_attr_cdev_type.attr,
- &dev_attr_max_state.attr,
- &dev_attr_cur_state.attr,
- NULL,
-};
-
-static const struct attribute_group cooling_device_attr_group = {
- .attrs = cooling_device_attrs,
-};
-
-static const struct attribute_group *cooling_device_attr_groups[] = {
- &cooling_device_attr_group,
- NULL,
-};
-
-static ssize_t
-thermal_cooling_device_weight_show(struct device *dev,
- struct device_attribute *attr, char *buf)
-{
- struct thermal_instance *instance;
-
- instance = container_of(attr, struct thermal_instance, weight_attr);
-
- return sprintf(buf, "%d\n", instance->weight);
-}
-
-static ssize_t
-thermal_cooling_device_weight_store(struct device *dev,
- struct device_attribute *attr,
- const char *buf, size_t count)
-{
- struct thermal_instance *instance;
- int ret, weight;
-
- ret = kstrtoint(buf, 0, &weight);
- if (ret)
- return ret;
-
- instance = container_of(attr, struct thermal_instance, weight_attr);
- instance->weight = weight;
-
- return count;
-}
/* Device management */
/**
@@ -1175,7 +1049,7 @@ __thermal_cooling_device_register(struct device_node *np,
cdev->ops = ops;
cdev->updated = false;
cdev->device.class = &thermal_class;
- cdev->device.groups = cooling_device_attr_groups;
+ thermal_cooling_device_setup_sysfs(cdev);
cdev->devdata = devdata;
dev_set_name(&cdev->device, "cooling_device%d", cdev->id);
result = device_register(&cdev->device);