diff options
author | Sreekanth Reddy <Sreekanth.Reddy@lsi.com> | 2013-02-01 21:49:30 +0530 |
---|---|---|
committer | James Bottomley <JBottomley@Parallels.com> | 2013-02-24 08:48:15 +0000 |
commit | 7887ea7f942770c2146dbcdfa2a85aa8de93df31 (patch) | |
tree | ac74a72d1daf5a64dea0340331780cef0af1f898 /drivers/scsi | |
parent | bfae7820b87c61c5065338b55405b304d9890085 (diff) | |
download | linux-7887ea7f942770c2146dbcdfa2a85aa8de93df31.tar.bz2 |
[SCSI] mpt2sas: Add support for OEM specific controller
Defined SSDID & HW vendor brand strings. Added entries for SSDID within the
function that prints the brand string.
Signed-off-by: Sreekanth Reddy <Sreekanth.Reddy@lsi.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Diffstat (limited to 'drivers/scsi')
-rw-r--r-- | drivers/scsi/mpt2sas/mpt2sas_base.c | 8 | ||||
-rw-r--r-- | drivers/scsi/mpt2sas/mpt2sas_base.h | 6 |
2 files changed, 14 insertions, 0 deletions
diff --git a/drivers/scsi/mpt2sas/mpt2sas_base.c b/drivers/scsi/mpt2sas/mpt2sas_base.c index 5e24e7e73714..bcb23d28b3e8 100644 --- a/drivers/scsi/mpt2sas/mpt2sas_base.c +++ b/drivers/scsi/mpt2sas/mpt2sas_base.c @@ -2023,6 +2023,14 @@ _base_display_intel_branding(struct MPT2SAS_ADAPTER *ioc) printk(MPT2SAS_INFO_FMT "%s\n", ioc->name, MPT2SAS_INTEL_RMS25KB040_BRANDING); break; + case MPT2SAS_INTEL_RMS25LB040_SSDID: + printk(MPT2SAS_INFO_FMT "%s\n", ioc->name, + MPT2SAS_INTEL_RMS25LB040_BRANDING); + break; + case MPT2SAS_INTEL_RMS25LB080_SSDID: + printk(MPT2SAS_INFO_FMT "%s\n", ioc->name, + MPT2SAS_INTEL_RMS25LB080_BRANDING); + break; default: break; } diff --git a/drivers/scsi/mpt2sas/mpt2sas_base.h b/drivers/scsi/mpt2sas/mpt2sas_base.h index c6ee7aad7501..4caaac13682f 100644 --- a/drivers/scsi/mpt2sas/mpt2sas_base.h +++ b/drivers/scsi/mpt2sas/mpt2sas_base.h @@ -165,6 +165,10 @@ "Intel(R) Integrated RAID Module RMS25KB080" #define MPT2SAS_INTEL_RMS25KB040_BRANDING \ "Intel(R) Integrated RAID Module RMS25KB040" +#define MPT2SAS_INTEL_RMS25LB040_BRANDING \ + "Intel(R) Integrated RAID Module RMS25LB040" +#define MPT2SAS_INTEL_RMS25LB080_BRANDING \ + "Intel(R) Integrated RAID Module RMS25LB080" #define MPT2SAS_INTEL_RMS2LL080_BRANDING \ "Intel Integrated RAID Module RMS2LL080" #define MPT2SAS_INTEL_RMS2LL040_BRANDING \ @@ -180,6 +184,8 @@ #define MPT2SAS_INTEL_RMS25JB040_SSDID 0x3517 #define MPT2SAS_INTEL_RMS25KB080_SSDID 0x3518 #define MPT2SAS_INTEL_RMS25KB040_SSDID 0x3519 +#define MPT2SAS_INTEL_RMS25LB040_SSDID 0x351A +#define MPT2SAS_INTEL_RMS25LB080_SSDID 0x351B #define MPT2SAS_INTEL_RMS2LL080_SSDID 0x350E #define MPT2SAS_INTEL_RMS2LL040_SSDID 0x350F #define MPT2SAS_INTEL_RS25GB008_SSDID 0x3000 |