diff options
author | Bjorn Andersson <bjorn.andersson@sonymobile.com> | 2015-01-27 18:46:31 -0800 |
---|---|---|
committer | Mark Brown <broonie@kernel.org> | 2015-01-28 19:52:15 +0000 |
commit | 8460ef38872a89cf1f95b37ee2707ec32dc8ec0b (patch) | |
tree | 2891ab74003fda5e3269126f59f1718140fa659c /drivers/regulator | |
parent | 97bf6af1f928216fd6c5a66e8a57bfa95a659672 (diff) | |
download | linux-8460ef38872a89cf1f95b37ee2707ec32dc8ec0b.tar.bz2 |
regulator: core: Consolidate drms update handling
Refactor drms_uA_update() slightly to allow regulator_set_optimum_mode()
to utilize the same logic instead of duplicating it.
Signed-off-by: Bjorn Andersson <bjorn.andersson@sonymobile.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Diffstat (limited to 'drivers/regulator')
-rw-r--r-- | drivers/regulator/core.c | 112 |
1 files changed, 35 insertions, 77 deletions
diff --git a/drivers/regulator/core.c b/drivers/regulator/core.c index e225711bb8bc..0e0d8297dc8e 100644 --- a/drivers/regulator/core.c +++ b/drivers/regulator/core.c @@ -658,23 +658,32 @@ static struct class regulator_class = { /* Calculate the new optimum regulator operating mode based on the new total * consumer load. All locks held by caller */ -static void drms_uA_update(struct regulator_dev *rdev) +static int drms_uA_update(struct regulator_dev *rdev) { struct regulator *sibling; int current_uA = 0, output_uV, input_uV, err; unsigned int mode; + /* + * first check to see if we can set modes at all, otherwise just + * tell the consumer everything is OK. + */ err = regulator_check_drms(rdev); - if (err < 0 || !rdev->desc->ops->get_optimum_mode || - (!rdev->desc->ops->get_voltage && - !rdev->desc->ops->get_voltage_sel) || - !rdev->desc->ops->set_mode) - return; + if (err < 0) + return 0; + + if (!rdev->desc->ops->get_optimum_mode) + return 0; + + if (!rdev->desc->ops->set_mode) + return -EINVAL; /* get output voltage */ output_uV = _regulator_get_voltage(rdev); - if (output_uV <= 0) - return; + if (output_uV <= 0) { + rdev_err(rdev, "invalid output voltage found\n"); + return -EINVAL; + } /* get input voltage */ input_uV = 0; @@ -682,8 +691,10 @@ static void drms_uA_update(struct regulator_dev *rdev) input_uV = regulator_get_voltage(rdev->supply); if (input_uV <= 0) input_uV = rdev->constraints->input_uV; - if (input_uV <= 0) - return; + if (input_uV <= 0) { + rdev_err(rdev, "invalid input voltage found\n"); + return -EINVAL; + } /* calc total requested load */ list_for_each_entry(sibling, &rdev->consumer_list, list) @@ -695,8 +706,17 @@ static void drms_uA_update(struct regulator_dev *rdev) /* check the new mode is allowed */ err = regulator_mode_constrain(rdev, &mode); - if (err == 0) - rdev->desc->ops->set_mode(rdev, mode); + if (err < 0) { + rdev_err(rdev, "failed to get optimum mode @ %d uA %d -> %d uV\n", + current_uA, input_uV, output_uV); + return err; + } + + err = rdev->desc->ops->set_mode(rdev, mode); + if (err < 0) + rdev_err(rdev, "failed to set optimum mode %x\n", mode); + + return err; } static int suspend_set_state(struct regulator_dev *rdev, @@ -3024,75 +3044,13 @@ EXPORT_SYMBOL_GPL(regulator_get_mode); int regulator_set_optimum_mode(struct regulator *regulator, int uA_load) { struct regulator_dev *rdev = regulator->rdev; - struct regulator *consumer; - int ret, output_uV, input_uV = 0, total_uA_load = 0; - unsigned int mode; - - if (rdev->supply) - input_uV = regulator_get_voltage(rdev->supply); + int ret; mutex_lock(&rdev->mutex); - - /* - * first check to see if we can set modes at all, otherwise just - * tell the consumer everything is OK. - */ regulator->uA_load = uA_load; - ret = regulator_check_drms(rdev); - if (ret < 0) { - ret = 0; - goto out; - } - - if (!rdev->desc->ops->get_optimum_mode) - goto out; - - /* - * we can actually do this so any errors are indicators of - * potential real failure. - */ - ret = -EINVAL; - - if (!rdev->desc->ops->set_mode) - goto out; - - /* get output voltage */ - output_uV = _regulator_get_voltage(rdev); - if (output_uV <= 0) { - rdev_err(rdev, "invalid output voltage found\n"); - goto out; - } - - /* No supply? Use constraint voltage */ - if (input_uV <= 0) - input_uV = rdev->constraints->input_uV; - if (input_uV <= 0) { - rdev_err(rdev, "invalid input voltage found\n"); - goto out; - } - - /* calc total requested load for this regulator */ - list_for_each_entry(consumer, &rdev->consumer_list, list) - total_uA_load += consumer->uA_load; - - mode = rdev->desc->ops->get_optimum_mode(rdev, - input_uV, output_uV, - total_uA_load); - ret = regulator_mode_constrain(rdev, &mode); - if (ret < 0) { - rdev_err(rdev, "failed to get optimum mode @ %d uA %d -> %d uV\n", - total_uA_load, input_uV, output_uV); - goto out; - } - - ret = rdev->desc->ops->set_mode(rdev, mode); - if (ret < 0) { - rdev_err(rdev, "failed to set optimum mode %x\n", mode); - goto out; - } - ret = mode; -out: + ret = drms_uA_update(rdev); mutex_unlock(&rdev->mutex); + return ret; } EXPORT_SYMBOL_GPL(regulator_set_optimum_mode); |