net/mlx5: E-Switch, fix single FDB creation on BlueField
Always use MLX5_FLOW_TABLE_OTHER_VPORT flag when creating egress ACL table for single FDB. Not doing so on BlueField will make firmware fail the command. On BlueField the E-Switch manager is the ECPF (vport 0xFFFE) which is filled in the flow table creation command but as the other_vport field wasn't set the firmware complains about a bad parameter. This is different from a regular HCA where the E-Switch manager vport is the PF (vport 0x0). Passing MLX5_FLOW_TABLE_OTHER_VPORT will make the firmware happy both on BlueField and on regular HCAs without special condition for each. This fixes the bellow firmware syndrome: mlx5_cmd_check:819:(pid 571): CREATE_FLOW_TABLE(0x930) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0x754a4) Fixes: db202995f503 ("net/mlx5: E-Switch, add logic to enable shared FDB") Signed-off-by: Mark Bloch <mbloch@nvidia.com> Reviewed-by: Maor Gottlieb <maorg@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
Diffstat (limited to 'drivers/net/ethernet/mellanox/mlx5/core/eswitch_offloads.c')
-rw-r--r--drivers/net/ethernet/mellanox/mlx5/core/eswitch_offloads.c1
1 files changed, 1 insertions, 0 deletions
diff --git a/drivers/net/ethernet/mellanox/mlx5/core/eswitch_offloads.c b/drivers/net/ethernet/mellanox/mlx5/core/eswitch_offloads.c
index a46455694f7a..275af1d2b4d3 100644
--- a/drivers/net/ethernet/mellanox/mlx5/core/eswitch_offloads.c
+++ b/drivers/net/ethernet/mellanox/mlx5/core/eswitch_offloads.c
@@ -2512,6 +2512,7 @@ static int esw_set_master_egress_rule(struct mlx5_core_dev *master,
struct mlx5_eswitch *esw = master->priv.eswitch;
struct mlx5_flow_table_attr ft_attr = {
.max_fte = 1, .prio = 0, .level = 0,
+ .flags = MLX5_FLOW_TABLE_OTHER_VPORT,
};
struct mlx5_flow_namespace *egress_ns;
struct mlx5_flow_table *acl;