bcache: fix refcount underflow in bcache_device_free()
The problematic code piece in bcache_device_free() is,
785 static void bcache_device_free(struct bcache_device *d)
786 {
787 struct gendisk *disk = d->disk;
[snipped]
799 if (disk) {
800 if (disk->flags & GENHD_FL_UP)
801 del_gendisk(disk);
802
803 if (disk->queue)
804 blk_cleanup_queue(disk->queue);
805
806 ida_simple_remove(&bcache_device_idx,
807 first_minor_to_idx(disk->first_minor));
808 put_disk(disk);
809 }
[snipped]
816 }
At line 808, put_disk(disk) may encounter kobject refcount of 'disk'
being underflow.
Here is how to reproduce the issue,
- Attche the backing device to a cache device and do random write to
make the cache being dirty.
- Stop the bcache device while the cache device has dirty data of the
backing device.
- Only register the backing device back, NOT register cache device.
- The bcache device node /dev/bcache0 won't show up, because backing
device waits for the cache device shows up for the missing dirty
data.
- Now echo 1 into /sys/fs/bcache/pendings_cleanup, to stop the pending
backing device.
- After the pending backing device stopped, use 'dmesg' to check kernel
message, a use-after-free warning from KASA reported the refcount of
kobject linked to the 'disk' is underflow.
The dropping refcount at line 808 in the above code piece is added by
add_disk(d->disk) in bch_cached_dev_run(). But in the above condition
the cache device is not registered, bch_cached_dev_run() has no chance
to be called and the refcount is not added. The put_disk() for a non-
added refcount of gendisk kobject triggers a underflow warning.
This patch checks whether GENHD_FL_UP is set in disk->flags, if it is
not set then the bcache device was not added, don't call put_disk()
and the the underflow issue can be avoided.
Signed-off-by: Coly Li <colyli@suse.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Diffstat (limited to 'drivers/md')
-rw-r--r-- | drivers/md/bcache/super.c | 7 |
1 files changed, 5 insertions, 2 deletions
diff --git a/drivers/md/bcache/super.c b/drivers/md/bcache/super.c index 467149f3bcc5..a10a3c78f4ff 100644 --- a/drivers/md/bcache/super.c +++ b/drivers/md/bcache/super.c @@ -797,7 +797,9 @@ static void bcache_device_free(struct bcache_device *d) bcache_device_detach(d); if (disk) { - if (disk->flags & GENHD_FL_UP) + bool disk_added = (disk->flags & GENHD_FL_UP) != 0; + + if (disk_added) del_gendisk(disk); if (disk->queue) @@ -805,7 +807,8 @@ static void bcache_device_free(struct bcache_device *d) ida_simple_remove(&bcache_device_idx, first_minor_to_idx(disk->first_minor)); - put_disk(disk); + if (disk_added) + put_disk(disk); } bioset_exit(&d->bio_split); |