diff options
author | Bartlomiej Zolnierkiewicz <bzolnier@gmail.com> | 2008-08-18 21:40:04 +0200 |
---|---|---|
committer | Bartlomiej Zolnierkiewicz <bzolnier@gmail.com> | 2008-08-18 21:40:04 +0200 |
commit | 1b427a33b06ae76c64c1ad9af899a45b682ba6c6 (patch) | |
tree | 45870fae6b6b50bc014b089f65270e8d6dd460e2 /drivers/ide | |
parent | fc99856a45cab8040f07d93d52fabd11834bf544 (diff) | |
download | linux-1b427a33b06ae76c64c1ad9af899a45b682ba6c6.tar.bz2 |
sgiioc4: fixup message on resource allocation failure
There can be more than one sgiioc4 card in the system so print
also PCI device name on resource allocation failure (so we know
which one is the problematic one).
Reported-by: Jeremy Higdon <jeremy@sgi.com>
Signed-off-by: Bartlomiej Zolnierkiewicz <bzolnier@gmail.com>
Diffstat (limited to 'drivers/ide')
-rw-r--r-- | drivers/ide/pci/sgiioc4.c | 4 |
1 files changed, 2 insertions, 2 deletions
diff --git a/drivers/ide/pci/sgiioc4.c b/drivers/ide/pci/sgiioc4.c index 42eef19a18f1..681306c9d79b 100644 --- a/drivers/ide/pci/sgiioc4.c +++ b/drivers/ide/pci/sgiioc4.c @@ -621,9 +621,9 @@ sgiioc4_ide_setup_pci_device(struct pci_dev *dev) if (!request_mem_region(cmd_phys_base, IOC4_CMD_CTL_BLK_SIZE, DRV_NAME)) { printk(KERN_ERR - "%s : %s -- ERROR, Addresses " + "%s %s: -- ERROR, Addresses " "0x%p to 0x%p ALREADY in use\n", - __func__, DRV_NAME, (void *) cmd_phys_base, + DRV_NAME, pci_name(dev), (void *)cmd_phys_base, (void *) cmd_phys_base + IOC4_CMD_CTL_BLK_SIZE); return -ENOMEM; } |