summaryrefslogtreecommitdiffstats
path: root/drivers/edac
diff options
context:
space:
mode:
authorMauro Carvalho Chehab <mchehab@redhat.com>2010-08-21 01:03:52 -0300
committerMauro Carvalho Chehab <mchehab@redhat.com>2010-10-24 11:20:41 -0200
commit79daef2099a02fed35747c23bad22f30441133ea (patch)
tree6bdc6f1383d399fe35c89ec3158831cd67a5a932 /drivers/edac
parent88ef5ea9767b0c7bfb4b477e1857629fe8fa2983 (diff)
downloadlinux-79daef2099a02fed35747c23bad22f30441133ea.tar.bz2
i7core_edac: Fix refcount error at PCI devices
Probably due to a bug or some testing logic at PCI level, device refcount for <bus>:00.0 device is decremented at the end of the pci_get_device, made by i7core_get_all_devices(). The fact is that the first versions of the driver relied on those devices to probe for Nehalem, but the current versions don't use it at all. So, let's just remove those devices from the driver, making it simpler and fixing the bug. Signed-off-by: Mauro Carvalho Chehab <mchehab@redhat.com>
Diffstat (limited to 'drivers/edac')
-rw-r--r--drivers/edac/i7core_edac.c37
1 files changed, 2 insertions, 35 deletions
diff --git a/drivers/edac/i7core_edac.c b/drivers/edac/i7core_edac.c
index d55f74a6cd49..9868796f4871 100644
--- a/drivers/edac/i7core_edac.c
+++ b/drivers/edac/i7core_edac.c
@@ -281,7 +281,8 @@ static const struct pci_id_descr pci_dev_descr_i7core_nehalem[] = {
/* Memory controller */
{ PCI_DESCR(3, 0, PCI_DEVICE_ID_INTEL_I7_MCR) },
{ PCI_DESCR(3, 1, PCI_DEVICE_ID_INTEL_I7_MC_TAD) },
- /* Exists only for RDIMM */
+
+ /* Exists only for RDIMM */
{ PCI_DESCR(3, 2, PCI_DEVICE_ID_INTEL_I7_MC_RAS), .optional = 1 },
{ PCI_DESCR(3, 4, PCI_DEVICE_ID_INTEL_I7_MC_TEST) },
@@ -302,16 +303,6 @@ static const struct pci_id_descr pci_dev_descr_i7core_nehalem[] = {
{ PCI_DESCR(6, 1, PCI_DEVICE_ID_INTEL_I7_MC_CH2_ADDR) },
{ PCI_DESCR(6, 2, PCI_DEVICE_ID_INTEL_I7_MC_CH2_RANK) },
{ PCI_DESCR(6, 3, PCI_DEVICE_ID_INTEL_I7_MC_CH2_TC) },
-
- /* Generic Non-core registers */
- /*
- * This is the PCI device on i7core and on Xeon 35xx (8086:2c41)
- * On Xeon 55xx, however, it has a different id (8086:2c40). So,
- * the probing code needs to test for the other address in case of
- * failure of this one
- */
- { PCI_DESCR(0, 0, PCI_DEVICE_ID_INTEL_I7_NONCORE) },
-
};
static const struct pci_id_descr pci_dev_descr_lynnfield[] = {
@@ -328,12 +319,6 @@ static const struct pci_id_descr pci_dev_descr_lynnfield[] = {
{ PCI_DESCR( 5, 1, PCI_DEVICE_ID_INTEL_LYNNFIELD_MC_CH1_ADDR) },
{ PCI_DESCR( 5, 2, PCI_DEVICE_ID_INTEL_LYNNFIELD_MC_CH1_RANK) },
{ PCI_DESCR( 5, 3, PCI_DEVICE_ID_INTEL_LYNNFIELD_MC_CH1_TC) },
-
- /*
- * This is the PCI device has an alternate address on some
- * processors like Core i7 860
- */
- { PCI_DESCR( 0, 0, PCI_DEVICE_ID_INTEL_LYNNFIELD_NONCORE) },
};
static const struct pci_id_descr pci_dev_descr_i7core_westmere[] = {
@@ -361,10 +346,6 @@ static const struct pci_id_descr pci_dev_descr_i7core_westmere[] = {
{ PCI_DESCR(6, 1, PCI_DEVICE_ID_INTEL_LYNNFIELD_MC_CH2_ADDR_REV2) },
{ PCI_DESCR(6, 2, PCI_DEVICE_ID_INTEL_LYNNFIELD_MC_CH2_RANK_REV2) },
{ PCI_DESCR(6, 3, PCI_DEVICE_ID_INTEL_LYNNFIELD_MC_CH2_TC_REV2) },
-
- /* Generic Non-core registers */
- { PCI_DESCR(0, 0, PCI_DEVICE_ID_INTEL_LYNNFIELD_NONCORE_REV2) },
-
};
#define PCI_ID_TABLE_ENTRY(A) { .descr=A, .n_devs = ARRAY_SIZE(A) }
@@ -1342,20 +1323,6 @@ static int i7core_get_onedevice(struct pci_dev **prev,
pdev = pci_get_device(PCI_VENDOR_ID_INTEL,
dev_descr->dev_id, *prev);
- /*
- * On Xeon 55xx, the Intel Quckpath Arch Generic Non-core regs
- * is at addr 8086:2c40, instead of 8086:2c41. So, we need
- * to probe for the alternate address in case of failure
- */
- if (dev_descr->dev_id == PCI_DEVICE_ID_INTEL_I7_NONCORE && !pdev)
- pdev = pci_get_device(PCI_VENDOR_ID_INTEL,
- PCI_DEVICE_ID_INTEL_I7_NONCORE_ALT, *prev);
-
- if (dev_descr->dev_id == PCI_DEVICE_ID_INTEL_LYNNFIELD_NONCORE && !pdev)
- pdev = pci_get_device(PCI_VENDOR_ID_INTEL,
- PCI_DEVICE_ID_INTEL_LYNNFIELD_NONCORE_ALT,
- *prev);
-
if (!pdev) {
if (*prev) {
*prev = pdev;