authorPunit Agrawal <punit.agrawal@arm.com>2015-11-17 12:06:22 +0000
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>2015-12-10 00:14:58 +0100
commitf8fa8ae06b8c2c25d81c99766f9226adc5c3e073 (patch)
tree4c2b761f47ee1261e969e5e5e2eb8d1c74a94cdb /drivers/cpufreq
parent3be3f8f36e7349006f19c8c8f0d686e98462a993 (diff)
downloadlinux-f8fa8ae06b8c2c25d81c99766f9226adc5c3e073.tar.bz2
cpufreq-dt: Supply power coefficient when registering cooling devices
Support registering cooling devices with dynamic power coefficient where provided by the device tree. This allows OF registered cooling devices driver to be used with the power_allocator thermal governor. Signed-off-by: Punit Agrawal <punit.agrawal@arm.com> Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Reviewed-by: Javi Merino <javi.merino@arm.com> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r--drivers/cpufreq/cpufreq-dt.c9
1 files changed, 7 insertions, 2 deletions
diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c
index 90d64081ddb3..1ceece9d6711 100644
--- a/drivers/cpufreq/cpufreq-dt.c
+++ b/drivers/cpufreq/cpufreq-dt.c
@@ -407,8 +407,13 @@ static void cpufreq_ready(struct cpufreq_policy *policy)
* thermal DT code takes care of matching them.
*/
if (of_find_property(np, "#cooling-cells", NULL)) {
- priv->cdev = of_cpufreq_cooling_register(np,
- policy->related_cpus);
+ u32 power_coefficient = 0;
+
+ of_property_read_u32(np, "dynamic-power-coefficient",
+ &power_coefficient);
+
+ priv->cdev = of_cpufreq_power_cooling_register(np,
+ policy->related_cpus, power_coefficient, NULL);
if (IS_ERR(priv->cdev)) {
dev_err(priv->cpu_dev,
"running cpufreq without cooling device: %ld\n",