diff options
author | Ilya Dryomov <ilya.dryomov@inktank.com> | 2014-05-13 11:19:27 +0400 |
---|---|---|
committer | Yan, Zheng <zheng.z.yan@intel.com> | 2014-06-06 09:29:58 +0800 |
commit | 30ba1f020221991cf239d905c82984958f29bdfe (patch) | |
tree | 343cad430c508927f86c5b756d1dabd50c1aa1d3 /drivers/block | |
parent | 6044cde6f2a94d88142d4401624152a741866338 (diff) | |
download | linux-30ba1f020221991cf239d905c82984958f29bdfe.tar.bz2 |
rbd: make sure we have latest osdmap on 'rbd map'
Given an existing idle mapping (img1), mapping an image (img2) in
a newly created pool (pool2) fails:
$ ceph osd pool create pool1 8 8
$ rbd create --size 1000 pool1/img1
$ sudo rbd map pool1/img1
$ ceph osd pool create pool2 8 8
$ rbd create --size 1000 pool2/img2
$ sudo rbd map pool2/img2
rbd: sysfs write failed
rbd: map failed: (2) No such file or directory
This is because client instances are shared by default and we don't
request an osdmap update when bumping a ref on an existing client. The
fix is to use the mon_get_version request to see if the osdmap we have
is the latest, and block until the requested update is received if it's
not.
Fixes: http://tracker.ceph.com/issues/8184
Signed-off-by: Ilya Dryomov <ilya.dryomov@inktank.com>
Reviewed-by: Sage Weil <sage@inktank.com>
Diffstat (limited to 'drivers/block')
-rw-r--r-- | drivers/block/rbd.c | 36 |
1 files changed, 33 insertions, 3 deletions
diff --git a/drivers/block/rbd.c b/drivers/block/rbd.c index 552a2edcaa74..daf7b4659b4a 100644 --- a/drivers/block/rbd.c +++ b/drivers/block/rbd.c @@ -4683,6 +4683,38 @@ out_err: } /* + * Return pool id (>= 0) or a negative error code. + */ +static int rbd_add_get_pool_id(struct rbd_client *rbdc, const char *pool_name) +{ + u64 newest_epoch; + unsigned long timeout = rbdc->client->options->mount_timeout * HZ; + int tries = 0; + int ret; + +again: + ret = ceph_pg_poolid_by_name(rbdc->client->osdc.osdmap, pool_name); + if (ret == -ENOENT && tries++ < 1) { + ret = ceph_monc_do_get_version(&rbdc->client->monc, "osdmap", + &newest_epoch); + if (ret < 0) + return ret; + + if (rbdc->client->osdc.osdmap->epoch < newest_epoch) { + ceph_monc_request_next_osdmap(&rbdc->client->monc); + (void) ceph_monc_wait_osdmap(&rbdc->client->monc, + newest_epoch, timeout); + goto again; + } else { + /* the osdmap we have is new enough */ + return -ENOENT; + } + } + + return ret; +} + +/* * An rbd format 2 image has a unique identifier, distinct from the * name given to it by the user. Internally, that identifier is * what's used to specify the names of objects related to the image. @@ -5053,7 +5085,6 @@ static ssize_t do_rbd_add(struct bus_type *bus, struct rbd_options *rbd_opts = NULL; struct rbd_spec *spec = NULL; struct rbd_client *rbdc; - struct ceph_osd_client *osdc; bool read_only; int rc = -ENOMEM; @@ -5075,8 +5106,7 @@ static ssize_t do_rbd_add(struct bus_type *bus, } /* pick the pool */ - osdc = &rbdc->client->osdc; - rc = ceph_pg_poolid_by_name(osdc->osdmap, spec->pool_name); + rc = rbd_add_get_pool_id(rbdc, spec->pool_name); if (rc < 0) goto err_out_client; spec->pool_id = (u64)rc; |