summaryrefslogtreecommitdiffstats
path: root/arch
diff options
context:
space:
mode:
authorAdrian Hunter <adrian.hunter@intel.com>2020-03-26 10:01:47 +0200
committerArnaldo Carvalho de Melo <acme@redhat.com>2020-04-03 09:37:56 -0300
commit47327f56674d69a423f7167f8d4ea537cc1762cc (patch)
tree342d0f89a087912e531d43b933e6b1a6146ab2ff /arch
parentd2bedb7863e9817f71fe2332a85ecdbd0f264b4b (diff)
downloadlinux-47327f56674d69a423f7167f8d4ea537cc1762cc.tar.bz2
perf events parser: Add missing Intel CPU events to parser
perf list expects CPU events to be parseable by name, e.g. # perf list | grep el-capacity-read el-capacity-read OR cpu/el-capacity-read/ [Kernel PMU event] But the event parser does not recognize them that way, e.g. # perf test -v "Parse event" <SNIP> running test 54 'cycles//u' running test 55 'cycles:k' running test 0 'cpu/config=10,config1,config2=3,period=1000/u' running test 1 'cpu/config=1,name=krava/u,cpu/config=2/u' running test 2 'cpu/config=1,call-graph=fp,time,period=100000/,cpu/config=2,call-graph=no,time=0,period=2000/' running test 3 'cpu/name='COMPLEX_CYCLES_NAME:orig=cycles,desc=chip-clock-ticks',period=0x1,event=0x2/ukp' -> cpu/event=0,umask=0x11/ -> cpu/event=0,umask=0x13/ -> cpu/event=0x54,umask=0x1/ failed to parse event 'el-capacity-read:u,cpu/event=el-capacity-read/u', err 1, str 'parser error' event syntax error: 'el-capacity-read:u,cpu/event=el-capacity-read/u' \___ parser error test child finished with 1 ---- end ---- Parse event definition strings: FAILED! This happens because the parser splits names by '-' in order to deal with cache events. For example 'L1-dcache' is a token in parse-events.l which is matched to 'L1-dcache-load-miss' by the following rule: PE_NAME_CACHE_TYPE '-' PE_NAME_CACHE_OP_RESULT '-' PE_NAME_CACHE_OP_RESULT opt_event_config And so there is special handling for 2-part PMU names i.e. PE_PMU_EVENT_PRE '-' PE_PMU_EVENT_SUF sep_dc but no handling for 3-part names, which are instead added as tokens e.g. topdown-[a-z-]+ While it would be possible to add a rule for 3-part names, that would not work if the first parts were also a valid PMU name e.g. 'el-capacity-read' would be matched to 'el-capacity' before the parser reached the 3rd part. The parser would need significant change to rationalize all this, so instead fix for now by adding missing Intel CPU events with 3-part names to the event parser as tokens. Missing events were found by using: grep -r EVENT_ATTR_STR arch/x86/events/intel/core.c Signed-off-by: Adrian Hunter <adrian.hunter@intel.com> Acked-by: Jiri Olsa <jolsa@redhat.com> Cc: Kan Liang <kan.liang@linux.intel.com> Link: http://lore.kernel.org/lkml/90c7ae07-c568-b6d3-f9c4-d0c1528a0610@intel.com Signed-off-by: Arnaldo Carvalho de Melo <acme@redhat.com>
Diffstat (limited to 'arch')
0 files changed, 0 insertions, 0 deletions