summaryrefslogtreecommitdiffstats
path: root/arch
diff options
context:
space:
mode:
authorLinas Vepstas <linas@austin.ibm.com>2006-06-19 15:07:40 -0500
committerPaul Mackerras <paulus@samba.org>2006-06-21 15:01:32 +1000
commit0aa8d15b01881ccaab5f2fb31eef33ced97ccb5f (patch)
tree398d2b5c20d56073ade09e2e3bc1032bf6130324 /arch
parent379507181a1e330d4f5b0fabe61cd43eccf09763 (diff)
downloadlinux-0aa8d15b01881ccaab5f2fb31eef33ced97ccb5f.tar.bz2
[POWERPC] pseries: Print PCI slot location code on failure
The PCI error recovery code will printk diagnostic info when a PCI error event occurs. Change the messages to include the slot location code, which is how most sysadmins will know the device. Signed-off-by: Linas Vepstas <linas@austin.ibm.com> Signed-off-by: Paul Mackerras <paulus@samba.org>
Diffstat (limited to 'arch')
-rw-r--r--arch/powerpc/platforms/pseries/eeh_driver.c35
1 files changed, 22 insertions, 13 deletions
diff --git a/arch/powerpc/platforms/pseries/eeh_driver.c b/arch/powerpc/platforms/pseries/eeh_driver.c
index 4d45347afabc..0ec9a5445b95 100644
--- a/arch/powerpc/platforms/pseries/eeh_driver.c
+++ b/arch/powerpc/platforms/pseries/eeh_driver.c
@@ -261,16 +261,22 @@ struct pci_dn * handle_eeh_events (struct eeh_event *event)
struct pci_bus *frozen_bus;
int rc = 0;
enum pci_ers_result result = PCI_ERS_RESULT_NONE;
- const char *pci_str, *drv_str;
+ const char *location, *pci_str, *drv_str;
frozen_dn = find_device_pe(event->dn);
frozen_bus = pcibios_find_pci_bus(frozen_dn);
if (!frozen_dn) {
- printk(KERN_ERR "EEH: Error: Cannot find partition endpoint for %s\n",
- pci_name(event->dev));
+
+ location = (char *) get_property(event->dn, "ibm,loc-code", NULL);
+ location = location ? location : "unknown";
+ printk(KERN_ERR "EEH: Error: Cannot find partition endpoint "
+ "for location=%s pci addr=%s\n",
+ location, pci_name(event->dev));
return NULL;
}
+ location = (char *) get_property(frozen_dn, "ibm,loc-code", NULL);
+ location = location ? location : "unknown";
/* There are two different styles for coming up with the PE.
* In the old style, it was the highest EEH-capable device
@@ -282,8 +288,9 @@ struct pci_dn * handle_eeh_events (struct eeh_event *event)
frozen_bus = pcibios_find_pci_bus (frozen_dn->parent);
if (!frozen_bus) {
- printk(KERN_ERR "EEH: Cannot find PCI bus for %s\n",
- frozen_dn->full_name);
+ printk(KERN_ERR "EEH: Cannot find PCI bus "
+ "for location=%s dn=%s\n",
+ location, frozen_dn->full_name);
return NULL;
}
@@ -318,8 +325,9 @@ struct pci_dn * handle_eeh_events (struct eeh_event *event)
eeh_slot_error_detail(frozen_pdn, 1 /* Temporary Error */);
printk(KERN_WARNING
- "EEH: This PCI device has failed %d times since last reboot: %s - %s\n",
- frozen_pdn->eeh_freeze_count, drv_str, pci_str);
+ "EEH: This PCI device has failed %d times since last reboot: "
+ "location=%s driver=%s pci addr=%s\n",
+ frozen_pdn->eeh_freeze_count, location, drv_str, pci_str);
/* Walk the various device drivers attached to this slot through
* a reset sequence, giving each an opportunity to do what it needs
@@ -368,17 +376,18 @@ excess_failures:
* due to actual, failed cards.
*/
printk(KERN_ERR
- "EEH: PCI device %s - %s has failed %d times \n"
- "and has been permanently disabled. Please try reseating\n"
- "this device or replacing it.\n",
- drv_str, pci_str, frozen_pdn->eeh_freeze_count);
+ "EEH: PCI device at location=%s driver=%s pci addr=%s \n"
+ "has failed %d times and has been permanently disabled. \n"
+ "Please try reseating this device or replacing it.\n",
+ location, drv_str, pci_str, frozen_pdn->eeh_freeze_count);
goto perm_error;
hard_fail:
printk(KERN_ERR
- "EEH: Unable to recover from failure of PCI device %s - %s\n"
+ "EEH: Unable to recover from failure of PCI device "
+ "at location=%s driver=%s pci addr=%s \n"
"Please try reseating this device or replacing it.\n",
- drv_str, pci_str);
+ location, drv_str, pci_str);
perm_error:
eeh_slot_error_detail(frozen_pdn, 2 /* Permanent Error */);