hwmon: (it87) Fix thermal sensor type values
The it87 driver doesn't follow the standard sensor type values as
documented in Documentation/hwmon/sysfs-interface. It uses value 2 for
thermistors instead of value 4. This causes "sensors" to tell the user
that the chip is setup for a transistor while it is actually setup for
a thermistor.
Using value 4 for thermistors solves the problem. For compatibility
reasons, we still accept value 2 but emit a warning message so that
users update their configuration files.
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Acked-by: Hans de Goede <hdegoede@redhat.com>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r-- | Documentation/hwmon/it87 | 4 |
1 files changed, 2 insertions, 2 deletions
diff --git a/Documentation/hwmon/it87 b/Documentation/hwmon/it87 index 3496b7020e7c..042c0415140b 100644 --- a/Documentation/hwmon/it87 +++ b/Documentation/hwmon/it87 @@ -136,10 +136,10 @@ once-only alarms. The IT87xx only updates its values each 1.5 seconds; reading it more often will do no harm, but will return 'old' values. -To change sensor N to a thermistor, 'echo 2 > tempN_type' where N is 1, 2, +To change sensor N to a thermistor, 'echo 4 > tempN_type' where N is 1, 2, or 3. To change sensor N to a thermal diode, 'echo 3 > tempN_type'. Give 0 for unused sensor. Any other value is invalid. To configure this at -startup, consult lm_sensors's /etc/sensors.conf. (2 = thermistor; +startup, consult lm_sensors's /etc/sensors.conf. (4 = thermistor; 3 = thermal diode) |