diff options
author | Juerg Haefliger <juergh@gmail.com> | 2006-09-24 20:55:34 +0200 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@suse.de> | 2006-09-28 15:31:16 -0700 |
commit | a1fdcb96ee33ba75318476a2a4691147c9f2ad90 (patch) | |
tree | ac5d846a5ad4106406b793abacd168075d7e59b8 /Documentation/hwmon | |
parent | 61d0b53363256e87aeb79286be2dc8f62a9d429a (diff) | |
download | linux-a1fdcb96ee33ba75318476a2a4691147c9f2ad90.tar.bz2 |
vt1211: Document module parameters
vt1211: Document module parameters
Add a description of the module parameters to the documentation of
the vt1211 driver.
Signed-off-by: Juerg Haefliger <juergh@gmail.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r-- | Documentation/hwmon/vt1211 | 24 |
1 files changed, 21 insertions, 3 deletions
diff --git a/Documentation/hwmon/vt1211 b/Documentation/hwmon/vt1211 index d6d807138195..77fa633b97a8 100644 --- a/Documentation/hwmon/vt1211 +++ b/Documentation/hwmon/vt1211 @@ -16,6 +16,26 @@ Thanks to Joseph Chan and Fiona Gatt from VIA for providing documentation and technical support. +Module Parameters +----------------- + +* uch_config: int Override the BIOS default universal channel (UCH) + configuration for channels 1-5. + Legal values are in the range of 0-31. Bit 0 maps to + UCH1, bit 1 maps to UCH2 and so on. Setting a bit to 1 + enables the thermal input of that particular UCH and + setting a bit to 0 enables the voltage input. + +* int_mode: int Override the BIOS default temperature interrupt mode. + The only possible value is 0 which forces interrupt + mode 0. In this mode, any pending interrupt is cleared + when the status register is read but is regenerated as + long as the temperature stays above the hysteresis + limit. + +Be aware that overriding BIOS defaults might cause some unwanted side effects! + + Description ----------- @@ -88,9 +108,7 @@ has a high limit which triggers an alarm if crossed. There is an associated hysteresis value with each temperature below which the temperature has to drop before the alarm is cleared (this is only true for interrupt mode 0). The interrupt mode can be forced to 0 in case the BIOS doesn't do it -automatically. For that, the parameter int_mode=0 needs to be supplied when -loading the driver module. Be aware that overriding BIOS defaults might cause -some unwanted side effects! +automatically. See the 'Module Parameters' section for details. All temperature channels except temp2 are external. Temp2 is the VT1211 internal thermal diode and the driver does all the scaling for temp2 and |