summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/sht21
diff options
context:
space:
mode:
authorMauro Carvalho Chehab <mchehab+samsung@kernel.org>2019-04-17 06:46:29 -0300
committerGuenter Roeck <linux@roeck-us.net>2019-04-17 10:37:23 -0700
commit7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7 (patch)
tree9db30159bd32bec125c7d49e80a79bb7c4da0c8e /Documentation/hwmon/sht21
parentb04f2f7d387b3160883c2a1f5e2285483a791e82 (diff)
downloadlinux-7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7.tar.bz2
docs: hwmon: Add an index file and rename docs to *.rst
Now that all files were converted to ReST format, rename them and add an index. Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon/sht21')
-rw-r--r--Documentation/hwmon/sht2168
1 files changed, 0 insertions, 68 deletions
diff --git a/Documentation/hwmon/sht21 b/Documentation/hwmon/sht21
deleted file mode 100644
index f1f5da030108..000000000000
--- a/Documentation/hwmon/sht21
+++ /dev/null
@@ -1,68 +0,0 @@
-Kernel driver sht21
-===================
-
-Supported chips:
-
- * Sensirion SHT21
-
- Prefix: 'sht21'
-
- Addresses scanned: none
-
- Datasheet: Publicly available at the Sensirion website
-
- http://www.sensirion.com/file/datasheet_sht21
-
-
-
- * Sensirion SHT25
-
- Prefix: 'sht25'
-
- Addresses scanned: none
-
- Datasheet: Publicly available at the Sensirion website
-
- http://www.sensirion.com/file/datasheet_sht25
-
-
-
-Author:
-
- Urs Fleisch <urs.fleisch@sensirion.com>
-
-Description
------------
-
-The SHT21 and SHT25 are humidity and temperature sensors in a DFN package of
-only 3 x 3 mm footprint and 1.1 mm height. The difference between the two
-devices is the higher level of precision of the SHT25 (1.8% relative humidity,
-0.2 degree Celsius) compared with the SHT21 (2.0% relative humidity,
-0.3 degree Celsius).
-
-The devices communicate with the I2C protocol. All sensors are set to the same
-I2C address 0x40, so an entry with I2C_BOARD_INFO("sht21", 0x40) can be used
-in the board setup code.
-
-sysfs-Interface
----------------
-
-temp1_input
- - temperature input
-
-humidity1_input
- - humidity input
-eic
- - Electronic Identification Code
-
-Notes
------
-
-The driver uses the default resolution settings of 12 bit for humidity and 14
-bit for temperature, which results in typical measurement times of 22 ms for
-humidity and 66 ms for temperature. To keep self heating below 0.1 degree
-Celsius, the device should not be active for more than 10% of the time,
-e.g. maximum two measurements per second at the given resolution.
-
-Different resolutions, the on-chip heater, and using the CRC checksum
-are not supported yet.