summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/lm85
diff options
context:
space:
mode:
authorMauro Carvalho Chehab <mchehab+samsung@kernel.org>2019-04-17 06:46:28 -0300
committerGuenter Roeck <linux@roeck-us.net>2019-04-17 10:36:05 -0700
commitb04f2f7d387b3160883c2a1f5e2285483a791e82 (patch)
treeb834fd1570d09542b32408c5b1a03d57db6f9dd5 /Documentation/hwmon/lm85
parentb32570a4f0919569bcba13a5419ea97ca5c1d3cf (diff)
downloadlinux-b04f2f7d387b3160883c2a1f5e2285483a791e82.tar.bz2
docs: hwmon: convert remaining files to ReST format
Convert all other hwmon files to ReST format, in order to allow them to be parsed by Sphinx. Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon/lm85')
-rw-r--r--Documentation/hwmon/lm8597
1 files changed, 73 insertions, 24 deletions
diff --git a/Documentation/hwmon/lm85 b/Documentation/hwmon/lm85
index 2329c383efe4..faa92f54431c 100644
--- a/Documentation/hwmon/lm85
+++ b/Documentation/hwmon/lm85
@@ -2,49 +2,85 @@ Kernel driver lm85
==================
Supported chips:
+
* National Semiconductor LM85 (B and C versions)
+
Prefix: 'lm85b' or 'lm85c'
+
Addresses scanned: I2C 0x2c, 0x2d, 0x2e
+
Datasheet: http://www.national.com/pf/LM/LM85.html
+
* Texas Instruments LM96000
+
Prefix: 'lm9600'
+
Addresses scanned: I2C 0x2c, 0x2d, 0x2e
+
Datasheet: http://www.ti.com/lit/ds/symlink/lm96000.pdf
+
* Analog Devices ADM1027
+
Prefix: 'adm1027'
+
Addresses scanned: I2C 0x2c, 0x2d, 0x2e
+
Datasheet: http://www.onsemi.com/PowerSolutions/product.do?id=ADM1027
+
* Analog Devices ADT7463
+
Prefix: 'adt7463'
+
Addresses scanned: I2C 0x2c, 0x2d, 0x2e
+
Datasheet: http://www.onsemi.com/PowerSolutions/product.do?id=ADT7463
+
* Analog Devices ADT7468
+
Prefix: 'adt7468'
+
Addresses scanned: I2C 0x2c, 0x2d, 0x2e
+
Datasheet: http://www.onsemi.com/PowerSolutions/product.do?id=ADT7468
+
* SMSC EMC6D100, SMSC EMC6D101
+
Prefix: 'emc6d100'
+
Addresses scanned: I2C 0x2c, 0x2d, 0x2e
- Datasheet: http://www.smsc.com/media/Downloads_Public/discontinued/6d100.pdf
+
+ Datasheet: http://www.smsc.com/media/Downloads_Public/discontinued/6d100.pdf
+
* SMSC EMC6D102
+
Prefix: 'emc6d102'
+
Addresses scanned: I2C 0x2c, 0x2d, 0x2e
+
Datasheet: http://www.smsc.com/main/catalog/emc6d102.html
+
* SMSC EMC6D103
+
Prefix: 'emc6d103'
+
Addresses scanned: I2C 0x2c, 0x2d, 0x2e
+
Datasheet: http://www.smsc.com/main/catalog/emc6d103.html
+
* SMSC EMC6D103S
+
Prefix: 'emc6d103s'
+
Addresses scanned: I2C 0x2c, 0x2d, 0x2e
+
Datasheet: http://www.smsc.com/main/catalog/emc6d103s.html
Authors:
- Philip Pokorny <ppokorny@penguincomputing.com>,
- Frodo Looijaard <frodol@dds.nl>,
- Richard Barrington <rich_b_nz@clear.net.nz>,
- Margit Schubert-While <margitsw@t-online.de>,
- Justin Thiessen <jthiessen@penguincomputing.com>
+ - Philip Pokorny <ppokorny@penguincomputing.com>,
+ - Frodo Looijaard <frodol@dds.nl>,
+ - Richard Barrington <rich_b_nz@clear.net.nz>,
+ - Margit Schubert-While <margitsw@t-online.de>,
+ - Justin Thiessen <jthiessen@penguincomputing.com>
Description
-----------
@@ -177,38 +213,50 @@ Each temperature sensor is associated with a Zone. There are three
sensors and therefore three zones (# 1, 2 and 3). Each zone has the following
temperature configuration points:
-* temp#_auto_temp_off - temperature below which fans should be off or spinning very low.
-* temp#_auto_temp_min - temperature over which fans start to spin.
-* temp#_auto_temp_max - temperature when fans spin at full speed.
-* temp#_auto_temp_crit - temperature when all fans will run full speed.
+* temp#_auto_temp_off
+ - temperature below which fans should be off or spinning very low.
+* temp#_auto_temp_min
+ - temperature over which fans start to spin.
+* temp#_auto_temp_max
+ - temperature when fans spin at full speed.
+* temp#_auto_temp_crit
+ - temperature when all fans will run full speed.
-* PWM Control
+PWM Control
+^^^^^^^^^^^
There are three PWM outputs. The LM85 datasheet suggests that the
pwm3 output control both fan3 and fan4. Each PWM can be individually
configured and assigned to a zone for its control value. Each PWM can be
configured individually according to the following options.
-* pwm#_auto_pwm_min - this specifies the PWM value for temp#_auto_temp_off
- temperature. (PWM value from 0 to 255)
+* pwm#_auto_pwm_min
+ - this specifies the PWM value for temp#_auto_temp_off
+ temperature. (PWM value from 0 to 255)
+
+* pwm#_auto_pwm_minctl
+ - this flags selects for temp#_auto_temp_off temperature
+ the behaviour of fans. Write 1 to let fans spinning at
+ pwm#_auto_pwm_min or write 0 to let them off.
-* pwm#_auto_pwm_minctl - this flags selects for temp#_auto_temp_off temperature
- the behaviour of fans. Write 1 to let fans spinning at
- pwm#_auto_pwm_min or write 0 to let them off.
+.. note::
-NOTE: It has been reported that there is a bug in the LM85 that causes the flag
-to be associated with the zones not the PWMs. This contradicts all the
-published documentation. Setting pwm#_min_ctl in this case actually affects all
-PWMs controlled by zone '#'.
+ It has been reported that there is a bug in the LM85 that causes
+ the flag to be associated with the zones not the PWMs. This
+ contradicts all the published documentation. Setting pwm#_min_ctl
+ in this case actually affects all PWMs controlled by zone '#'.
-* PWM Controlling Zone selection
+PWM Controlling Zone selection
+^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
-* pwm#_auto_channels - controls zone that is associated with PWM
+* pwm#_auto_channels
+ - controls zone that is associated with PWM
Configuration choices:
- Value Meaning
- ------ ------------------------------------------------
+========== =============================================
+Value Meaning
+========== =============================================
1 Controlled by Zone 1
2 Controlled by Zone 2
3 Controlled by Zone 3
@@ -217,6 +265,7 @@ Configuration choices:
0 PWM always 0% (off)
-1 PWM always 100% (full on)
-2 Manual control (write to 'pwm#' to set)
+========== =============================================
The National LM85's have two vendor specific configuration
features. Tach. mode and Spinup Control. For more details on these,