summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorHans Verkuil <hans.verkuil@cisco.com>2017-06-07 11:46:08 -0300
committerMauro Carvalho Chehab <mchehab@s-opensource.com>2017-06-20 06:51:21 -0300
commit23111ec304166750479e17318b7175ff7db0d6ac (patch)
treeba0549ef87d364e73d3ca98c3d2df348a9b6f329
parentacec3630155763c170c7ae6508cf973355464508 (diff)
downloadlinux-23111ec304166750479e17318b7175ff7db0d6ac.tar.bz2
[media] cec: add cec_s_phys_addr_from_edid helper function
This function simplifies the integration of CEC in DRM drivers. Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com> Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
-rw-r--r--Documentation/media/kapi/cec-core.rst8
-rw-r--r--drivers/media/cec/cec-adap.c14
-rw-r--r--include/media/cec.h9
3 files changed, 31 insertions, 0 deletions
diff --git a/Documentation/media/kapi/cec-core.rst b/Documentation/media/kapi/cec-core.rst
index 7a04c5386dc8..278b358b2f2e 100644
--- a/Documentation/media/kapi/cec-core.rst
+++ b/Documentation/media/kapi/cec-core.rst
@@ -307,6 +307,14 @@ to another valid physical address, then this function will first set the
address to CEC_PHYS_ADDR_INVALID before enabling the new physical address.
.. c:function::
+ void cec_s_phys_addr_from_edid(struct cec_adapter *adap,
+ const struct edid *edid);
+
+A helper function that extracts the physical address from the edid struct
+and calls cec_s_phys_addr() with that address, or CEC_PHYS_ADDR_INVALID
+if the EDID did not contain a physical address or edid was a NULL pointer.
+
+.. c:function::
int cec_s_log_addrs(struct cec_adapter *adap,
struct cec_log_addrs *log_addrs, bool block);
diff --git a/drivers/media/cec/cec-adap.c b/drivers/media/cec/cec-adap.c
index fd6d9cccade7..61e39bbe3cf9 100644
--- a/drivers/media/cec/cec-adap.c
+++ b/drivers/media/cec/cec-adap.c
@@ -28,6 +28,8 @@
#include <linux/string.h>
#include <linux/types.h>
+#include <drm/drm_edid.h>
+
#include "cec-priv.h"
static void cec_fill_msg_report_features(struct cec_adapter *adap,
@@ -1408,6 +1410,18 @@ void cec_s_phys_addr(struct cec_adapter *adap, u16 phys_addr, bool block)
}
EXPORT_SYMBOL_GPL(cec_s_phys_addr);
+void cec_s_phys_addr_from_edid(struct cec_adapter *adap,
+ const struct edid *edid)
+{
+ u16 pa = CEC_PHYS_ADDR_INVALID;
+
+ if (edid && edid->extensions)
+ pa = cec_get_edid_phys_addr((const u8 *)edid,
+ EDID_LENGTH * (edid->extensions + 1), NULL);
+ cec_s_phys_addr(adap, pa, false);
+}
+EXPORT_SYMBOL_GPL(cec_s_phys_addr_from_edid);
+
/*
* Called from either the ioctl or a driver to set the logical addresses.
*
diff --git a/include/media/cec.h b/include/media/cec.h
index bfa88d4d67e1..a548b292eeb1 100644
--- a/include/media/cec.h
+++ b/include/media/cec.h
@@ -206,6 +206,8 @@ static inline bool cec_is_sink(const struct cec_adapter *adap)
#define cec_phys_addr_exp(pa) \
((pa) >> 12), ((pa) >> 8) & 0xf, ((pa) >> 4) & 0xf, (pa) & 0xf
+struct edid;
+
#if IS_ENABLED(CONFIG_CEC_CORE)
struct cec_adapter *cec_allocate_adapter(const struct cec_adap_ops *ops,
void *priv, const char *name, u32 caps, u8 available_las);
@@ -217,6 +219,8 @@ int cec_s_log_addrs(struct cec_adapter *adap, struct cec_log_addrs *log_addrs,
bool block);
void cec_s_phys_addr(struct cec_adapter *adap, u16 phys_addr,
bool block);
+void cec_s_phys_addr_from_edid(struct cec_adapter *adap,
+ const struct edid *edid);
int cec_transmit_msg(struct cec_adapter *adap, struct cec_msg *msg,
bool block);
@@ -326,6 +330,11 @@ static inline void cec_s_phys_addr(struct cec_adapter *adap, u16 phys_addr,
{
}
+static inline void cec_s_phys_addr_from_edid(struct cec_adapter *adap,
+ const struct edid *edid)
+{
+}
+
static inline u16 cec_get_edid_phys_addr(const u8 *edid, unsigned int size,
unsigned int *offset)
{