diff options
author | Mauro Carvalho Chehab <mchehab+samsung@kernel.org> | 2019-04-17 06:46:19 -0300 |
---|---|---|
committer | Guenter Roeck <linux@roeck-us.net> | 2019-04-17 09:51:03 -0700 |
commit | a4710b72190a5ee1953ffba60cdbdced52a28466 (patch) | |
tree | 208ac0b19e89ca331a47d14717edcbd60ad4eb4c | |
parent | 9e929c6745da58ab64d2d462ba46b661c03d2060 (diff) | |
download | linux-a4710b72190a5ee1953ffba60cdbdced52a28466.tar.bz2 |
docs: hwmon: ibmpowernv: convert to ReST format
Convert ibmpowernv to ReST format, in order to allow it to
be parsed by Sphinx.
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
-rw-r--r-- | Documentation/hwmon/ibmpowernv | 31 |
1 files changed, 19 insertions, 12 deletions
diff --git a/Documentation/hwmon/ibmpowernv b/Documentation/hwmon/ibmpowernv index 56468258711f..5d642bc3dec0 100644 --- a/Documentation/hwmon/ibmpowernv +++ b/Documentation/hwmon/ibmpowernv @@ -2,6 +2,7 @@ Kernel Driver IBMPOWERNV ======================== Supported systems: + * Any recent IBM P servers based on POWERNV platform Author: Neelesh Gupta @@ -29,10 +30,11 @@ CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'. Sysfs attributes ---------------- +======================= ======================================================= fanX_input Measured RPM value. fanX_min Threshold RPM for alert generation. -fanX_fault 0: No fail condition - 1: Failing fan +fanX_fault - 0: No fail condition + - 1: Failing fan tempX_input Measured ambient temperature. tempX_max Threshold ambient temperature for alert generation. @@ -42,20 +44,22 @@ tempX_enable Enable/disable all temperature sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its temperature sensors. - 1: Enable - 0: Disable + + - 1: Enable + - 0: Disable inX_input Measured power supply voltage (millivolt) -inX_fault 0: No fail condition. - 1: Failing power supply. +inX_fault - 0: No fail condition. + - 1: Failing power supply. inX_highest Historical maximum voltage inX_lowest Historical minimum voltage inX_enable Enable/disable all voltage sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its voltage sensors. - 1: Enable - 0: Disable + + - 1: Enable + - 0: Disable powerX_input Power consumption (microWatt) powerX_input_highest Historical maximum power @@ -64,8 +68,9 @@ powerX_enable Enable/disable all power sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its power sensors. - 1: Enable - 0: Disable + + - 1: Enable + - 0: Disable currX_input Measured current (milliampere) currX_highest Historical maximum current @@ -74,7 +79,9 @@ currX_enable Enable/disable all current sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its current sensors. - 1: Enable - 0: Disable + + - 1: Enable + - 0: Disable energyX_input Cumulative energy (microJoule) +======================= ======================================================= |