summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorMauro Carvalho Chehab <mchehab+samsung@kernel.org>2019-04-17 06:46:19 -0300
committerGuenter Roeck <linux@roeck-us.net>2019-04-17 09:51:03 -0700
commita4710b72190a5ee1953ffba60cdbdced52a28466 (patch)
tree208ac0b19e89ca331a47d14717edcbd60ad4eb4c
parent9e929c6745da58ab64d2d462ba46b661c03d2060 (diff)
downloadlinux-a4710b72190a5ee1953ffba60cdbdced52a28466.tar.bz2
docs: hwmon: ibmpowernv: convert to ReST format
Convert ibmpowernv to ReST format, in order to allow it to be parsed by Sphinx. Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
-rw-r--r--Documentation/hwmon/ibmpowernv31
1 files changed, 19 insertions, 12 deletions
diff --git a/Documentation/hwmon/ibmpowernv b/Documentation/hwmon/ibmpowernv
index 56468258711f..5d642bc3dec0 100644
--- a/Documentation/hwmon/ibmpowernv
+++ b/Documentation/hwmon/ibmpowernv
@@ -2,6 +2,7 @@ Kernel Driver IBMPOWERNV
========================
Supported systems:
+
* Any recent IBM P servers based on POWERNV platform
Author: Neelesh Gupta
@@ -29,10 +30,11 @@ CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'.
Sysfs attributes
----------------
+======================= =======================================================
fanX_input Measured RPM value.
fanX_min Threshold RPM for alert generation.
-fanX_fault 0: No fail condition
- 1: Failing fan
+fanX_fault - 0: No fail condition
+ - 1: Failing fan
tempX_input Measured ambient temperature.
tempX_max Threshold ambient temperature for alert generation.
@@ -42,20 +44,22 @@ tempX_enable Enable/disable all temperature sensors belonging to the
sub-group. In POWER9, this attribute corresponds to
each OCC. Using this attribute each OCC can be asked to
disable/enable all of its temperature sensors.
- 1: Enable
- 0: Disable
+
+ - 1: Enable
+ - 0: Disable
inX_input Measured power supply voltage (millivolt)
-inX_fault 0: No fail condition.
- 1: Failing power supply.
+inX_fault - 0: No fail condition.
+ - 1: Failing power supply.
inX_highest Historical maximum voltage
inX_lowest Historical minimum voltage
inX_enable Enable/disable all voltage sensors belonging to the
sub-group. In POWER9, this attribute corresponds to
each OCC. Using this attribute each OCC can be asked to
disable/enable all of its voltage sensors.
- 1: Enable
- 0: Disable
+
+ - 1: Enable
+ - 0: Disable
powerX_input Power consumption (microWatt)
powerX_input_highest Historical maximum power
@@ -64,8 +68,9 @@ powerX_enable Enable/disable all power sensors belonging to the
sub-group. In POWER9, this attribute corresponds to
each OCC. Using this attribute each OCC can be asked to
disable/enable all of its power sensors.
- 1: Enable
- 0: Disable
+
+ - 1: Enable
+ - 0: Disable
currX_input Measured current (milliampere)
currX_highest Historical maximum current
@@ -74,7 +79,9 @@ currX_enable Enable/disable all current sensors belonging to the
sub-group. In POWER9, this attribute corresponds to
each OCC. Using this attribute each OCC can be asked to
disable/enable all of its current sensors.
- 1: Enable
- 0: Disable
+
+ - 1: Enable
+ - 0: Disable
energyX_input Cumulative energy (microJoule)
+======================= =======================================================