dt-bindings: Add Tegra SDHCI pad pdpu offset bindings
Add bindings documentation for pad pull up and pull down offset values to be
programmed before executing automatic pad drive strength calibration.
Signed-off-by: Aapo Vienamo <avienamo@nvidia.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Acked-by: Thierry Reding <treding@nvidia.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
-rw-r--r-- | Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt | 35 |
1 files changed, 35 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt b/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt index 90c214dbfb16..9713e052f736 100644 --- a/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt +++ b/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt @@ -45,6 +45,37 @@ Optional properties for Tegra210 and Tegra186: for controllers supporting multiple voltage levels. The order of names should correspond to the pin configuration states in pinctrl-0 and pinctrl-1. +- nvidia,only-1-8-v : The presence of this property indicates that the + controller operates at a 1.8 V fixed I/O voltage. +- nvidia,pad-autocal-pull-up-offset-3v3, + nvidia,pad-autocal-pull-down-offset-3v3 : Specify drive strength + calibration offsets for 3.3 V signaling modes. +- nvidia,pad-autocal-pull-up-offset-1v8, + nvidia,pad-autocal-pull-down-offset-1v8 : Specify drive strength + calibration offsets for 1.8 V signaling modes. +- nvidia,pad-autocal-pull-up-offset-3v3-timeout, + nvidia,pad-autocal-pull-down-offset-3v3-timeout : Specify drive + strength used as a fallback in case the automatic calibration times + out on a 3.3 V signaling mode. +- nvidia,pad-autocal-pull-up-offset-1v8-timeout, + nvidia,pad-autocal-pull-down-offset-1v8-timeout : Specify drive + strength used as a fallback in case the automatic calibration times + out on a 1.8 V signaling mode. +- nvidia,pad-autocal-pull-up-offset-sdr104, + nvidia,pad-autocal-pull-down-offset-sdr104 : Specify drive strength + calibration offsets for SDR104 mode. +- nvidia,pad-autocal-pull-up-offset-hs400, + nvidia,pad-autocal-pull-down-offset-hs400 : Specify drive strength + calibration offsets for HS400 mode. + + Notes on the pad calibration pull up and pulldown offset values: + - The property values are drive codes which are programmed into the + PD_OFFSET and PU_OFFSET sections of the + SDHCI_TEGRA_AUTO_CAL_CONFIG register. + - A higher value corresponds to higher drive strength. Please refer + to the reference manual of the SoC for correct values. + - The SDR104 and HS400 timing specific values are used in + corresponding modes if specified. Example: sdhci@700b0000 { @@ -58,5 +89,9 @@ sdhci@700b0000 { pinctrl-names = "sdmmc-3v3", "sdmmc-1v8"; pinctrl-0 = <&sdmmc1_3v3>; pinctrl-1 = <&sdmmc1_1v8>; + nvidia,pad-autocal-pull-up-offset-3v3 = <0x00>; + nvidia,pad-autocal-pull-down-offset-3v3 = <0x7d>; + nvidia,pad-autocal-pull-up-offset-1v8 = <0x7b>; + nvidia,pad-autocal-pull-down-offset-1v8 = <0x7b>; status = "disabled"; }; |