From 5a4e5b78956a570cd827f74e4b94d506d13b37b0 Mon Sep 17 00:00:00 2001 From: Quentin Perret Date: Wed, 30 Oct 2019 15:14:50 +0000 Subject: thermal: cpu_cooling: Make the power-related code depend on IPA The core CPU cooling infrastructure has power-related functions that have only one client: IPA. Since there can be no user of those functions if IPA is not compiled in, make sure to guard them with checks on CONFIG_THERMAL_GOV_POWER_ALLOCATOR to not waste space unnecessarily. Acked-by: Daniel Lezcano Acked-by: Viresh Kumar Suggested-by: Daniel Lezcano Signed-off-by: Quentin Perret Signed-off-by: Daniel Lezcano Link: https://lore.kernel.org/r/20191030151451.7961-4-qperret@google.com --- drivers/thermal/cpu_cooling.c | 166 +++++++++++++++++++++--------------------- 1 file changed, 81 insertions(+), 85 deletions(-) (limited to 'drivers/thermal') diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 6b9865c786ba..cc6b84e41404 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -47,7 +47,9 @@ */ struct freq_table { u32 frequency; +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR u32 power; +#endif }; /** @@ -95,8 +97,7 @@ static DEFINE_IDA(cpufreq_ida); static DEFINE_MUTEX(cooling_list_lock); static LIST_HEAD(cpufreq_cdev_list); -/* Below code defines functions to be used for cpufreq as cooling device */ - +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR /** * get_level: Find the level for a particular frequency * @cpufreq_cdev: cpufreq_cdev for which the property is required @@ -265,76 +266,6 @@ static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev, return (raw_cpu_power * cpufreq_cdev->last_load) / 100; } -/* cpufreq cooling device callback functions are defined below */ - -/** - * cpufreq_get_max_state - callback function to get the max cooling state. - * @cdev: thermal cooling device pointer. - * @state: fill this variable with the max cooling state. - * - * Callback for the thermal cooling device to return the cpufreq - * max cooling state. - * - * Return: 0 on success, an error code otherwise. - */ -static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, - unsigned long *state) -{ - struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; - - *state = cpufreq_cdev->max_level; - return 0; -} - -/** - * cpufreq_get_cur_state - callback function to get the current cooling state. - * @cdev: thermal cooling device pointer. - * @state: fill this variable with the current cooling state. - * - * Callback for the thermal cooling device to return the cpufreq - * current cooling state. - * - * Return: 0 on success, an error code otherwise. - */ -static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, - unsigned long *state) -{ - struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; - - *state = cpufreq_cdev->cpufreq_state; - - return 0; -} - -/** - * cpufreq_set_cur_state - callback function to set the current cooling state. - * @cdev: thermal cooling device pointer. - * @state: set this variable to the current cooling state. - * - * Callback for the thermal cooling device to change the cpufreq - * current cooling state. - * - * Return: 0 on success, an error code otherwise. - */ -static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, - unsigned long state) -{ - struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; - - /* Request state should be less than max_level */ - if (WARN_ON(state > cpufreq_cdev->max_level)) - return -EINVAL; - - /* Check if the old cooling action is same as new cooling action */ - if (cpufreq_cdev->cpufreq_state == state) - return 0; - - cpufreq_cdev->cpufreq_state = state; - - return freq_qos_update_request(&cpufreq_cdev->qos_req, - cpufreq_cdev->freq_table[state].frequency); -} - /** * cpufreq_get_requested_power() - get the current power * @cdev: &thermal_cooling_device pointer @@ -478,22 +409,84 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev, power); return 0; } +#endif /* CONFIG_THERMAL_GOV_POWER_ALLOCATOR */ + +/* cpufreq cooling device callback functions are defined below */ + +/** + * cpufreq_get_max_state - callback function to get the max cooling state. + * @cdev: thermal cooling device pointer. + * @state: fill this variable with the max cooling state. + * + * Callback for the thermal cooling device to return the cpufreq + * max cooling state. + * + * Return: 0 on success, an error code otherwise. + */ +static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, + unsigned long *state) +{ + struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; + + *state = cpufreq_cdev->max_level; + return 0; +} + +/** + * cpufreq_get_cur_state - callback function to get the current cooling state. + * @cdev: thermal cooling device pointer. + * @state: fill this variable with the current cooling state. + * + * Callback for the thermal cooling device to return the cpufreq + * current cooling state. + * + * Return: 0 on success, an error code otherwise. + */ +static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, + unsigned long *state) +{ + struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; + + *state = cpufreq_cdev->cpufreq_state; + + return 0; +} + +/** + * cpufreq_set_cur_state - callback function to set the current cooling state. + * @cdev: thermal cooling device pointer. + * @state: set this variable to the current cooling state. + * + * Callback for the thermal cooling device to change the cpufreq + * current cooling state. + * + * Return: 0 on success, an error code otherwise. + */ +static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, + unsigned long state) +{ + struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; + + /* Request state should be less than max_level */ + if (WARN_ON(state > cpufreq_cdev->max_level)) + return -EINVAL; + + /* Check if the old cooling action is same as new cooling action */ + if (cpufreq_cdev->cpufreq_state == state) + return 0; + + cpufreq_cdev->cpufreq_state = state; + + return freq_qos_update_request(&cpufreq_cdev->qos_req, + cpufreq_cdev->freq_table[state].frequency); +} /* Bind cpufreq callbacks to thermal cooling device ops */ static struct thermal_cooling_device_ops cpufreq_cooling_ops = { - .get_max_state = cpufreq_get_max_state, - .get_cur_state = cpufreq_get_cur_state, - .set_cur_state = cpufreq_set_cur_state, -}; - -static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = { .get_max_state = cpufreq_get_max_state, .get_cur_state = cpufreq_get_cur_state, .set_cur_state = cpufreq_set_cur_state, - .get_requested_power = cpufreq_get_requested_power, - .state2power = cpufreq_state2power, - .power2state = cpufreq_power2state, }; static unsigned int find_next_max(struct cpufreq_frequency_table *table, @@ -603,17 +596,20 @@ __cpufreq_cooling_register(struct device_node *np, pr_debug("%s: freq:%u KHz\n", __func__, freq); } + cooling_ops = &cpufreq_cooling_ops; + +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR if (capacitance) { ret = update_freq_table(cpufreq_cdev, capacitance); if (ret) { cdev = ERR_PTR(ret); goto remove_ida; } - - cooling_ops = &cpufreq_power_cooling_ops; - } else { - cooling_ops = &cpufreq_cooling_ops; + cooling_ops->get_requested_power = cpufreq_get_requested_power; + cooling_ops->state2power = cpufreq_state2power; + cooling_ops->power2state = cpufreq_power2state; } +#endif ret = freq_qos_add_request(&policy->constraints, &cpufreq_cdev->qos_req, FREQ_QOS_MAX, -- cgit v1.2.3