From 5c174c41d8a702ade02fbb125b15f58158e4d1da Mon Sep 17 00:00:00 2001 From: Ian Abbott Date: Wed, 16 Oct 2013 14:40:33 +0100 Subject: staging: comedi: pcmuio: sample types are unsigned Sample values in comedi are generally represented as unsigned values. Change `pcmuio_handle_intr_subdev()` in the "pcmuio" module to use unsigned sample values for consistency. Also, make the order in which `pcmuio_handle_intr_subdev()` writes the two sample values (each actually containing up to 16 1-bit sample values) independent of the host byte ordering. Signed-off-by: Ian Abbott Signed-off-by: Greg Kroah-Hartman --- drivers/staging/comedi/drivers/pcmuio.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) (limited to 'drivers/staging/comedi') diff --git a/drivers/staging/comedi/drivers/pcmuio.c b/drivers/staging/comedi/drivers/pcmuio.c index 67e2bb1d66f0..954fa96a50ac 100644 --- a/drivers/staging/comedi/drivers/pcmuio.c +++ b/drivers/staging/comedi/drivers/pcmuio.c @@ -315,8 +315,8 @@ static void pcmuio_handle_intr_subdev(struct comedi_device *dev, } /* Write the scan to the buffer. */ - if (comedi_buf_put(s->async, ((short *)&val)[0]) && - comedi_buf_put(s->async, ((short *)&val)[1])) { + if (comedi_buf_put(s->async, val) && + comedi_buf_put(s->async, val >> 16)) { s->async->events |= (COMEDI_CB_BLOCK | COMEDI_CB_EOS); } else { /* Overflow! Stop acquisition!! */ -- cgit v1.2.3